Chilling and Service LED Alternate Blinking – Full Water Level Error
Possible Reason
Solution
Low Level and Overflow
Sensors indicted water but full
level sensor is not detected
Check connection to low water level sensor.
Replace full water level sensor
Heating, Chilling and Service LED Sequentially Blink
Possible Reason
Solution
Overflow sensor has detected
water but neither low or full
sensors are detected
Check connections to both low and full water sensors.
Replace both Low Water and Full Water Sensors
Heating, Chilling and Service LED Blinks Simultaneously
Possible Reason
Solution
All three level sensors have
detected water
Check Feed Valve for Debris.
Clean or replace feed valve.
Service LED is On – Leak Detection Probe has detected water
Possible Reason
Solution
Dry inside of unit and leak
detector.
Check unit for leak and repair or replace faulty parts.
WL800
Operating, Installation, and Service Manual Page 65 - Revision: 5-14-2015
Summary of Contents for WL800 - MAX II
Page 54: ...WL800 Operating Installation and Service Manual Page 54 Revision 5 14 2015...
Page 55: ...WL800 Operating Installation and Service Manual Page 55 Revision 5 14 2015...
Page 57: ...WL800 Operating Installation and Service Manual Page 57 Revision 5 14 2015...
Page 58: ...FRONT PBA WL800 Operating Installation and Service Manual Page 58 Revision 5 14 2015...
Page 60: ...WL800 Operating Installation and Service Manual Page 60 Revision 5 14 2015...
Page 61: ...WL800 Operating Installation and Service Manual Page 61 Revision 5 14 2015...
Page 62: ...SMPS WL800 Operating Installation and Service Manual Page 62 Revision 5 14 2015...
Page 63: ...SMPS WL800 Operating Installation and Service Manual Page 63 Revision 5 14 2015...