MODEL/PART DESIGNATIONS
BRAND NAME
DESCRIPTION
MODEL – PART NUMBER
WL800
Waterlogic WL800 – Cold and Hot
16-MAZH2
SPECIFICATIONS
ITEM
WL800
Water Connection
¼” Quick Connect
Cold Water Temperature
Cold Water Temperature – Factory Set Point 41° - 5°C
(Adjustable) 34
° -
54
°
F. (1.1
°
- 12.2
°
C)
Hot Water Temperature
158
°
- 203
°
F (70
°
- 95
°
C) Programmable
Recommended Service Pressure 40-60 psi (275-414 kPa) – Use Pressure Regulator
Maximum Working Pressure
60 psi (414 kPa) – Use Pressure Regulator
Environmental Temperature
35
°
- 100
°
F (2
°
- 37
°
C)
Refrigerant Gas
R134a – 2.29 oz. (65 grams) - Hi (290 psi) Low (90 psi)
R134a Pressures
High (290 psi), Low (90 psi)
SHIPPING SPECIFICATIONS
ITEM
DIMENSIONS
Width/Depth/Height
17 in. (440mm) x 20 in. (515mm) x 49.6 in. (1260mm)
Weight – Dry (w/o packaging) 93 lb. (42 kg)
Shipping Information
(length x width x height)
21.5 in. x 25 in. x 52 in.
4 units per pallet
Shipping Weight – Dry
103 lb. (46 kg)
ELECTRICAL SPECIFICATIONS
ELECTRICAL SUPPLY
15 Amp Service
+
COMPONENT
AMP DRAW (approximate)
Hot Tank Heater
4.45 Amps
Compressor
0.6 Amps
WL800
TOTAL
5.05 Amps
WL800
Operating, Installation, and Service Manual Page 7 - Revision: 5-14-2015
Summary of Contents for WL800 - MAX II
Page 54: ...WL800 Operating Installation and Service Manual Page 54 Revision 5 14 2015...
Page 55: ...WL800 Operating Installation and Service Manual Page 55 Revision 5 14 2015...
Page 57: ...WL800 Operating Installation and Service Manual Page 57 Revision 5 14 2015...
Page 58: ...FRONT PBA WL800 Operating Installation and Service Manual Page 58 Revision 5 14 2015...
Page 60: ...WL800 Operating Installation and Service Manual Page 60 Revision 5 14 2015...
Page 61: ...WL800 Operating Installation and Service Manual Page 61 Revision 5 14 2015...
Page 62: ...SMPS WL800 Operating Installation and Service Manual Page 62 Revision 5 14 2015...
Page 63: ...SMPS WL800 Operating Installation and Service Manual Page 63 Revision 5 14 2015...