13. OPERATING YOUR NEW SHOWER – Manual Model

Ensure that electric and water supplies are turned on. 

Turn on the shower by turning the temperature control knob anti-clockwise.

Adjust temperature as required. Flow rate can be varied by adjusting the flow control

knob.

Turn of f the shower by turning the temperature control knob fully clockwise.

There is no need to adjust the flow control when turning of f the shower.

14. OPERATING YOUR NEW OSPREY –

Thermostatic Model

Ensure electricity and both hot and cold water supplies are turned on. Turn on the

shower by pushing on/of f flow control knob.

Adjust temperature and flow rate as desired.

To turn of f, push on/of f flow control knob.

The temperature control is independent of the on/of f flow control and can be

left in the selected temperature position until the next time the shower is used.

There is no need to set to cold position.

The first time the shower is used there may be some residual air in the

system. This may cause uneven flow, spitting from the shower handset and unusual

noise from the pump. This should clear quickly and disappear with fur ther use.

Note: 

If the water flow stops but the pump continues to run, switch of f immediately.

Refer to Fault Finding Section 11, paragraph C.

15. SERVICING

The most common cause of poor shower per formance is blockage of the handset

spray plate holes. They are usually blocked by dir t or limescale deposits, which is

more common in hardwater areas. Regular cleaning and descaling is recommended. 

To maintain a good flow and spray pattern the handset should be cleaned

regularly. In hard water areas it should also be descaled dependent upon the rate of

scale build up.

The sur faces of the cabinet, hose, riser rail and handset should be cleaned

with a non abrasive cleaner only.

12

Summary of Contents for Osprey II Series

Page 1: ...POWER SHOWERS Models 4500M 5002M 4500T 5002T II Performance Shower Products CUSTOMER SERVICE HELPLINE 01883 730339...

Page 2: ...HE SHOWER 1 4 INSTALLATION Manual Model 2 5 WATER CONNECTIONS Manual Model 3 6 INSTALLATION Thermostatic Model 4 7 WATER CONNECTIONS Thermostatic Model 4 8 ELECTRICAL CONNECTIONS 6 9 ELECTRICAL CONNEC...

Page 3: ...ation boilers 3 A minumum supply head of 1 metre is required The water level in the cold water storage tank should be 1 metre above the unit 4 Do not use any jointing compounds such as Boss White Abra...

Page 4: ...of 40mm 15 8 It is recommended that a plywood base 10 12mm thick be cut to the shape of the outline and mounted on the wall behind this to give a flat mounting base There must be a clearance of 1 2mm...

Page 5: ...nd the cold supply to the top inlet The Osprey power shower can be connected via the either the side entry or back entry To gain access for back entry the access panel must be removed cut with a trimm...

Page 6: ...pipework if the back access is to be used First screw part way in the 2 top mounting screws while the 3rd bottom screw is inserted After completing installation of the mounting screws screw firmly int...

Page 7: ...h a knife as shown in Fig 8 Side Entry Measure and cut pipes using a pipe cutter not a hacksaw to correct length place pipe entry covers on pipes and push firmly into push fit connection the pipe must...

Page 8: ...ompliance with I E E Wiring Regulations BS 7671 If in doubt seek professional advice or assistance from a qualified electrician In the interests of safety it is recommended that a residual current dev...

Page 9: ...the cable restraint The installation kits are supplied with 5 metres of low voltage connecting lead The connecting leads between the pump and the isolating transformer can be extended up to about 15 m...

Page 10: ...the lower end of the riser rail into the bottom bracket locating its slot over the tongue in the aperture and press down the collar and disc to snap them home 9 Using a screw attach the top bracket th...

Page 11: ...set in mid position allowing water to flow for several minutes Check for leaks on supply pipe connections DO NOT TURN ON ELECTRICITY SUPPLY UNTIL FRONT COVER HAS BEEN INSTALLED PROCEED WITH COMPLETIO...

Page 12: ...ose without handset hang into shower tray or bath c Position temperature control knob in mid position Note The movement of the temperature control can be quite firm as the temperature setting is moved...

Page 13: ...rewdriver as shown in Fig 29 iii Using a sharp knife cut off one segment of the limit stop as shown in Fig 30 iv Replace temperature limit stop into control knob as shown in Fig 31 making sure to loca...

Page 14: ...e position until the next time the shower is used There is no need to set to cold position The first time the shower is used there may be some residual air in the system This may cause uneven flow spi...

Page 15: ...ls it will self reset D POOR WATER FLOW Clean handset spray plate E CUSTOMER SERVICE HELPLINE For advice during installation or assistance with any problems contact the Customer Service Helpline on 01...

Page 16: ...bove the inlet to the shower 3 a Do not use any jointing compounds abrasive compounds will cause seal to leak b When making pipe joints do NOT allow ANY solder flux to come in contact with plastic par...

Page 17: ...EW INDUSTRIAL ESTATE HOLLAND ROAD HURST GREEN OXTED SURREY RH8 9BD WATERMILL PRODUCTS LTD WATERMILL HOUSE FAIRVIEW INDUSTRIAL ESTATE HOLLAND ROAD HURST GREEN OXTED SURREY RH8 9BD Name Address Model No...

Page 18: ...unning or any damage resulting from faulty installation is not covered by the guarantee The integrity of the connections of the pump to the water supply and the shower system is the responsibility of...