Verify that the pipette adaptor is correctly installed.

Check the back of the pipette and verify that any marking is 
visible when the pipette adaptor is installed

iii. How to install Andrew Alliance pipettes on the     
   Robot stand

To equip the Robot 
with Andrew Alliance pipettes 
it is sufficient to place them in 
any available slot of the tool 
stand. It is not necessary to turn 
on the pipettes before placing 
them. The display of the pipette 
should be oriented toward the 
user as indicated in the picture 
on the right.

Please be sure that the metallic 
pins present on the side of the 
pipette are in contact with the 
metallic pins present in the slot 
of the tool stand.

iv. Labware gripper

The Labware gripper is a 
compact Bluetooth controlled 
device which allows the 
Robot to manipulate 
labware.

It is composed of two main 
parts: the clamp, whose 
geometry and shape can differ 
according to the consumable 
shape, and the body, 
responsible for communication 
with the Robot and 
the control of the actuator.

The Labware gripper does 
not require an adaptor and 
can be placed in any slot 
of the tool stand. It has two 
metallic pins on the side 
which allow the charging of 
the embedded battery and 
serial communication with the 
 Robot.

Summary of Contents for Andrew+Robot

Page 1: ...of the tip rack E External tool docking station F Liquid handling operations i Volumes in consumables G How to use the Andrew Robot H Maintenance i General information ii Recommended maintenance if t...

Page 2: ...on module LLD Liquid level detector TIS Tip insertion system ROW Rest of the world III ABBREVIATIONS USED I INSTRUCTION ICONS IV GLOSSARY Term Definition Tool Device which can be automatically handled...

Page 3: ...the Andrew Robot workspace so that the Andrew Robot can identify them Depending on your protocol you can have 2 Dominos for a small experiment and up to 11 Dominos compatible with multi channel pipet...

Page 4: ...oved only when the Andrew Robot is switched off or when its arm is folded back into the idle position The hand should be close to the shoulder The laboratory tools compatible with the Andrew Robot can...

Page 5: ...emperatures up to 37 C Altitude Up to 2000 m above mean sea level Safe operating conditions for the system Fluctuation of the supply voltage up to 10 of the rated voltage Transient overvoltage Degree...

Page 6: ...ut one of your hands on the base and the other hand on the top of the body then lift up the Andrew Robot DO NOT grab the Andrew Robot from its arms doing so will cause irreversible damage to the unit...

Page 7: ...to the power plug 2 Wait for the LED present on the Andrew Robot s body to turn blue and start blinking 3 Connect your computer tablet or smartphone to the Wi Fi name of the Andrew Robot 4 Go to you...

Page 8: ...ptor Position the pipette inside the pipette adaptor Once the pipette is correctly positioned close the pipette adaptor Use the two clamps to secure the tightness of the pipette inside the pipette ada...

Page 9: ...in the picture on the right Please be sure that the metallic pins present on the side of the pipette are in contact with the metallic pins present in the slot of the tool stand iv Labware gripper The...

Page 10: ...g execution of the experiment The waste Domino hosts a foldable silicone waste designed by Waters and capable of containing up to 900 pipette tips 1 mL VII HOW TO INSTALL THE WASTE DOMINO Facing the A...

Page 11: ...tional docking station capable of hosting up to 3 tools The power and data connections with the Andrew Robot are established via an electronic connector placed in the Waste Domino The docking station...

Page 12: ...unit is no longer accessible via OneLab The machine is in Standby status The machine is turned ON and it is put in Booting status 5 times 5 times press for 20 sec press for 5 sec press for 30 sec Eme...

Page 13: ...Dominos in its workbench It is composed of different steps Green fast heartbeat Different sounds depending on the step Start An experiment is starting Green fast heartbeat Experiment start Running An...

Page 14: ...notification Error Dead PC Communication with the PC is not possible Red horizontal line Error notification Standby PC Waste Domino and Arm are powered down Tool stand stand is powered Green fast hea...

Page 15: ...guaranteed The bench to which the Andrew Robot will be moved must be cleaned as well iii Compatible solvents with the Andrew Robot To clean all the parts of the Andrew Robot the compatibility with the...

Page 16: ...96 EC on Waste Electrical and Electronic Equipment WEEE FCC 47 CFR Part 18 This Class A digital apparatus complies with Canadian ICES 003 RoHS 2 2011 65 EU X CONTACT i How to contact the Andrew Robot...

Reviews: