background image

 

Date of installation :

Contact of your heating technician or your after-sales service. 

This appliance is marked with this symbol  This means that electrical and electronic products shall not be mixed with general household waste  
European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products  
Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment  

The dismantling and treatment of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations.

 

This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal waste stream  
Please contact the installer or local authority for more information  
* subject to the national law of each member state

Subject to modifications without notice. Non contractual documen

t.

Summary of Contents for WSYP100DG6

Page 1: ...40549 D sseldorf Germany Subject to modifications without notice Non contractual document WSYP100DG6 Heat pump air water split system hydraulicindoorunit Fujitsu General Euro GmbH Werftstrasse 20 4054...

Page 2: ...of the installation 5 Operation of the installation 6 User interface Room control unit option and Room thermostat option 6 Description of the display 8 Appliance start up 9 Quick start up 9 Setting th...

Page 3: ...with your installer Do not climb on the top of the outdoor unit The room in which the appliance is operating must be correctly ventilated in order to prevent any loss of oxygen if there is an escape...

Page 4: ...freely The great stability in a regulation system for floor heating systems avoids sharp differences in temperature However this stability involves a reaction time of the order of several hours approx...

Page 5: ...ontrol unit Heat pumps are systems that can be connected to any form of low temperature heat distribution systems the heat captured by the heat pump can therefore be used in different ways Floor heati...

Page 6: ...at option figure 2 C Auto Auto ESC OK 0 4 8 12 16 20 24 1 2 3 4 5 6 7 8 11 5 2 10 11 Room control unit T75 T78 Room thermostat T55 T58 1 2 3 4 5 6 7 8 9 User interface Operation manual 1780 EN Hydraul...

Page 7: ...ng to the heating program Summer winter mode switchover is automatic Constant comfort temperature Constant reduced temperature Stand by mode with anti frost protection Provided that the heat pump s el...

Page 8: ...r operation Default message Service Special operation INFO Information level activated PROG Program activated ECO ECO mode activated Heating temporarily stopped temperature ambiante Hour Parameter num...

Page 9: ...t time Engage the start stop switch During the regulator initialisation phase the display shows all the symbols and then Data update and then State heat pump Select the AUTO heating mode figure 6 Sele...

Page 10: ...to confirm Turn the knob Select line 1 Hours minutes Press OK to confirm The hour display flashes Turn the knob to set the time Press OK to confirm The minutes display flashes Turn the knob to set th...

Page 11: ...ase on 2nd phase off 3rd phase on 3rd phase off Default values Copy Mon Sun Mon Fri Sat Sun Monday Tuesday Sunday Holidays heating circuit 1 Holidays heating circuit 2 Operation level Period 1 Period...

Page 12: ...list Choose the desired menu Scroll the function lines Choose the desired line Adjust the parameter Check the setting by pressing OK To return the menu press ESC If no setting is made for 8 minutes t...

Page 13: ...ase Off end 00 00 10 min 17 00 565 3rd phase On start 00 00 10 min 566 3rd phase Off end 00 00 10 min 575 Copy 576 Standard values No Yes No Yes OK The standard values memorised in the regulator repla...

Page 14: ...eat delivered heating 2 3129 Heat delivered DHW 2 3130 Cooling delivered cooling 2 3131 Not used 3132 Not used 3133 Not used 3135 Heat delivered heating 3 3136 Heat delivered DHW 3 3137 Cooling delive...

Page 15: ...d DHW 10 3186 Cooling delivered cooling 10 3187 Not used 3188 Not used 3189 Not used Error 6711 Heat pump Reset No Yes No Maintenance special regime 7141 Emergency regime Off On Off Off Heat pump func...

Page 16: ...heat pump is operating electrical power failure or unprogrammed pressing of the on off switch on the hydraulic unit the display will show error 370 when the appliance restarts Do not be concerned the...

Page 17: ...rs on PROG mode or AUTO mode for piloting by the regulation board The difference between the comfort temperature and the reduced temperature is from 3 5 C Frost protection temperature is set directly...

Page 18: ...nstaller If frequent refills are required it is essential that you look for any leaks The frequent water supply is at risk of scaling for the Heat exchanger and degrades performance and longevity of i...

Page 19: ...Operation manual 1780 EN 19 Hydraulic indoor unit...

Page 20: ...as this could have harmful effects on your health and on the environment The dismantling and treatment of refrigerant oil and other parts must be done by a qualified installer in accordance with relev...

Reviews: