D
C
A
E
D
B
1.
4.
2.
3.
Squeeze and remove retaining clip (D). Pull cartridge (E) off system evenly at
top and bottom. Dispose of used cartridge. Install new cartridge, rocking gently
from side to side until cartridge tubes are properly engaged in unit connectors.
Re-install retaining clip, ensuring slide locks snap into place. If clip does not snap
easily into place through slots, cartridge is not fully inserted into connectors.
Failure to properly install retaining clip will result in accidental leaks and flooding.
Maintenance for the Multi-Stage Filtration System is quick and easy. All cartridges are designed to be changed without tools. When properly
maintained, the system will provide you with years of trouble-free service. Cartridges in this system must be replaced every 6-12 months to
maintain efficiency and to ensure high water quality.
Turn off cold water at angle stop (A) or
feed
water valve to the system (B)
.
Relieve water pressure by opening faucet
handle (C).
Squeeze sides to remove cover (D) from
front of system.
CARTRIDGE REPLACEMENT - Model # 30102
SYSTEM SPECIFICATIONS
System Life
1000 gallons
1st Stage Filter
20 micron Polypropylene
2nd Stage Filter
5 micron Polypropylene
3rd Stage Filter
GAC
System Dimensions (6 3/4”w x 6 1/2”d x 15 3/4”h)
System weight (dry) 4.75 lbs.
Feed water
Potable water
Min. feed pressure 40 psi
Max. feed pressure 100 psi
Min. feed temp
32°F
Max. feed temp
120°F