background image

2200 East Sturgis Road, Oxnard, CA  93030 • Ph. (805) 981-0262 • Fax (805) 981-9403

www.waterwayplastics.com • waterway@waterwayplastics.com

810-0187.1009

© 2009 Waterway Plastics

INSTALLATION & OPERATING INSTRUCTIONS

LO-PROFILE SPA DRAIN FILL VALVE (600-9101)

1. Find a place around the lower perimeter of the spa where the 
drain can be installed.  The hose on the back must be allowed to 
travel several inches back and forth freely.

3. Slide the body of the spa drain through the hole and secure 
with the nut.  Silicone can be added to the threads to prevent the 
nut from backing off.

4. The spa drain is designed to be used with ¾" spa flex hosing.  
Cut the flex pipe long so that it can travel back and forth freely 
with spa drain internal then glue it into the back of the spa drain 
using the proper PVC sealant.  

2. Mark where the drain is to be positioned and using a 2" hole 
saw, drill a hole through the spa wall.

Reviews: