background image

• 

This is an “Unblockable” SOFA. 

• 

Suction cover life is 7 years, the sump wall fitting life is 15 years, the rest of the components have 25 year life, cover and all  

  SOFA components shall be replaced on or before the end of service life. 

  The use of adhesives or other attachment methods that prevent access to suction piping or SOFA components is prohibited. 

  Please refer to Head Loss Curve, suction head measured at the wall fitting. 

  This is an unblockable SOFA as marked on the suction cover. 

  DO NOT USE POWER TOOLS TO INSTALL FASTENERS. Ensure proper thread engagement to prevent cross-threading. 

  Ensure proper flatness of installation surface. 

• 

When mud-rings, sump and other components are held in place by the interior surface of the pool, the surface should be free  

  of deterioration or voids

  Damaged Fasteners shall be replaced with original parts, and must be passitive grade 316 stainless steel. The wall fitting shall  

  be inspected for the presence of any CRACK or material loss. Cracked/damaged mud rings, sumps, or wall fittings shall  

  be  replaced.

  No unauthorized field modifications. 

  This product is intended for use on gunite, vinyl, fiberglass, and roto-molded pools, spas and hot tubs.

  No modification shall be made to SOFA structure or flow path unless the configuration has been certified as a new SOFA. 

  Service life begins the month and year in which SOFA components are installed with or without water. 

  For winterization remove the cover and plug the inlet. 

  Observe cover/grate/fasteners for damage each operational day. 

  During installation ensure components and fastener receptacles are clean, free of debris and obstructions. 

  Hand-check cover/grate for snugness to the sump/frame/wall fitting after installation. 

  SOFA installation components with crack, chunks, or pieces broken off, stripped screw holes, brittleness, and/or unusual  

  discoloration should be replaced. 

  The mounting surface or interior surface of the pool should be free of deterioration.

  Start installation of screws by hand to ensure proper thread engagement and to prevent cross-threading. 

  Do not exceed the safe flow rating of SOFAs as listed. 

  All SOFAs should be installed in accordance with Waterway installation instructions.

  No modification shall be made to SOFA structure or flow path unless new configuration has been certified as a new SOFA. 

  SOFA speficic flow ratings are not to be exceeded while the pool is open. 

  The capacity of secondary circulation system (skimmer, cutters, etc) should not be included when evaluating an individual  

  suction system flow rating.

  For the flow rating for pools with multiple blockable SOFAs in one body of water without isolation valves: combine all   

  SOFAs, minus the flow rate of one, if all are not equal use the larger flow rate. 

  “Blockable” SOFAs in new pools shall be installed in multiple-SOFA system ONLY.

  “Blockable” SOFAs in existing pools with single SOFA systems shall be installed with an additional anti-entrapment device  

  or system.

  This SOFA shall be used with Waterway sump or with Waterway mud-ring and field built sump per attached instructions. 

  Unauthorized field modifications will void certification. 

  Cover/grate, including fasteners, shall be observed for damage or tampering each operational day.

  The flow rating for pools with single or multiple unblockable SOFAs shall be the combined flow rate of all SOFAs piped together  

  on one body of water. 

  All SOFAs shall not be located on backrests or seats. 

Required Tools: 

Philips screw driver bit and torque wrench. Hand tighten screws. DO NOT use power tools.  Torque fasteners to a maximum  

of 48 in-lb.

Summary of Contents for 640-134x V

Page 1: ...rt installation of screws by hand to ensure proper thread engagement and prevent cross threading Replacement cover shall be only used onWaterway sump and mud rings All cracked or damaged mud rings or...

Page 2: ...e wall fitting after installation SOFA installation components with crack chunks or pieces broken off stripped screw holes brittleness and or unusual discoloration should be replaced The mounting surf...

Page 3: ...on the previous page Suction outlet components have a finite life The cover grate should be inspected frequently and replaced at least every seven years or if found to be damaged broken cracked missin...

Page 4: ...9910 2 Pipe Plug 3 6 642 1300 32 3 PortVinyl Liner Sump 1 7 715 1360 32 Plaster Cover Plug 1 5 6 7 4 3 2 1 Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tool...

Page 5: ...U Gasket 1 6 715 9910 2 Pipe Plug 3 7 642 1300 32 3 PortVinyl Liner Sump 1 6 7 4 5 3 2 1 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrica...

Page 6: ...ster Sump 1 5 715 1360 32 Plaster Cover Plug 1 4 3 1 2 5 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tighten...

Page 7: ...4 715 1360 32 Plaster Cover Plug 1 1 2 3 4 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tightening the screws...

Page 8: ...t is used Pressure tap located 19 25in downstream of port in 2 5in DIA schedule 40 PVC pipe When two outside ports used Pressure tap located 29 5in downstream of port in 2 5in DIA schedule 40 PVC pipe...

Page 9: ...THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FLOW PATH ZONE NOTE No reductions in plumbing size are permitted within 16...

Page 10: ...icated sumps shall be made as shown below 32 Min 16 2 38 FRAME PLASTER FINISH SURFACE OF THE POOL 32 Min 2 37 FRAME PLASTER FINISH SURFACE OF THE POOL 5 8 2 PIPE FRAME Part 642 1360 PLASTER FINISH SUR...

Reviews: