background image

  

FINISH SURFACE

OF THE POOL

SUCTION

PIPE

OPENING

  

FINISH SURFACE

OF THE POOL

SUCTION

PIPE

OPENING

  

FINISH SURFACE

OF THE POOL

SUCTION

PIPE

OPENING

  

FINISH SURFACE

OF THE POOL

SUCTION

PIPE

OPENING

FLOW PATH ZONE: 

NOTE: No reductions in plumbing size are permitted within 16" from the point of connection to the sump.

Flow Path 3"

Flow Path 3"

Summary of Contents for 640-134x V

Page 1: ...rt installation of screws by hand to ensure proper thread engagement and prevent cross threading Replacement cover shall be only used onWaterway sump and mud rings All cracked or damaged mud rings or...

Page 2: ...e wall fitting after installation SOFA installation components with crack chunks or pieces broken off stripped screw holes brittleness and or unusual discoloration should be replaced The mounting surf...

Page 3: ...on the previous page Suction outlet components have a finite life The cover grate should be inspected frequently and replaced at least every seven years or if found to be damaged broken cracked missin...

Page 4: ...9910 2 Pipe Plug 3 6 642 1300 32 3 PortVinyl Liner Sump 1 7 715 1360 32 Plaster Cover Plug 1 5 6 7 4 3 2 1 Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tool...

Page 5: ...U Gasket 1 6 715 9910 2 Pipe Plug 3 7 642 1300 32 3 PortVinyl Liner Sump 1 6 7 4 5 3 2 1 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrica...

Page 6: ...ster Sump 1 5 715 1360 32 Plaster Cover Plug 1 4 3 1 2 5 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tighten...

Page 7: ...4 715 1360 32 Plaster Cover Plug 1 1 2 3 4 810 0230 0221 2021 Waterway Plastics Hand tighten the screws using a Phillips screw driver DO NOT use electrical or pneumatic tools for tightening the screws...

Page 8: ...t is used Pressure tap located 19 25in downstream of port in 2 5in DIA schedule 40 PVC pipe When two outside ports used Pressure tap located 29 5in downstream of port in 2 5in DIA schedule 40 PVC pipe...

Page 9: ...THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FINISH SURFACE OF THE POOL SUCTION PIPE OPENING FLOW PATH ZONE NOTE No reductions in plumbing size are permitted within 16...

Page 10: ...icated sumps shall be made as shown below 32 Min 16 2 38 FRAME PLASTER FINISH SURFACE OF THE POOL 32 Min 2 37 FRAME PLASTER FINISH SURFACE OF THE POOL 5 8 2 PIPE FRAME Part 642 1360 PLASTER FINISH SUR...