background image

GRATE AND FRAME OWNER’S MANUAL

Read and keep these instructions for future reference. Follow all instructions in this 
owner’s manual and on the equipment. Failure to follow instructions can cause severe 
injury and/or death.

WARNING - SUCTION ENTRAPMENT HAZARD

Suction in suction outlets and/or suction outlet 
covers which are damaged, broken, cracked, 
missing, or unsecured can cause severe injury and/
or death due to the following entrapment hazards:

Hair Entrapment:

  Hair can become entangled in suction outlet cover.

Limb Entrapment:

  A limb inserted into an opening of a suction outlet 

sump or suction outlet cover that is damaged, broken, cracked, missing, 
or not securely attached can result in a mechanical bind or swelling of 
the limb.

Body Suction Entrapment:

  A negative pressure applied to a large 

portion of the body or limbs can result in an entrapment.

Evisceration / Disembowelment Entrapment:

  A negative pressure 

applied directly to the intestines through an unprotected suction 
outlet sump or suction outlet cover which is damaged, broken, cracked, 
missing, or unsecured can result in evisceration / disembowelment 
entrapment.

Mechanical Entrapment:

  There is potential for jewelry, swimsuit, 

hair decorations, finger, toe, or knuckle to be caught in an opening of a 
suction outlet cover resulting in mechanical entrapment.

•  Use two or more suction fitting on each  
pump suction line. The suction fittings    
shall be separated by a minimum of 3 ft. 
(91.44 cm), or if any are located closer they 
shall be located on two different planes 

  (i.e., one on the bottom and one on the vertical wall, or one each on  
  two separate vertical wall).
•   In the event of one suction outlet being completely blocked, the    
  remaining suction outlets serving that system shall have a flow    
  rating capable of the full flow of the pump(s) for the specific suction  
 system.
•   Dual suction fittings shall not be located on seating areas or on the  
  backrest for such seating areas.
•   The maximum system flow rate shall not exceed the flow rating of  

  any listed (per ASME A112.19.8-2007) suction outlet cover installed.  
  In the event of one suction outlet being completely blocked, the    
  remaining suction outlets serving the system shall have a flow rating  
  capable of the full flow of the pump(s).
•   Never use a pool or spa if any suction outlet component is damaged,  
  broken, cracked, missing, or not securely attached.
•   Replace damaged, broken, cracked, missing, or not securely attached  
  suction outlet components immediately.
•   Two or more suction outlets per pump should be installed in  

 

  accordance with latest APSP Standards and CPSC guidelines, and    
  follow all National, State, and Local codes applicable.
•   Replace the suction within 7 years from the installation date.
•   Installation of a vacuum release system, which relieves entrapping  
  suction, is recommended.

TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

USE ONLY GENUINE WATERWAY REPLACEMENT PARTS.

WARNING

IMPORTANT SAFETY INSTRUCTIONS

For Model Number:   640-475x V  (18" x 18")

VGB

2008

810-0217.0618

©2018 Waterway Plastics

2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403