Hand tighten the screws using a Phillips screw driver. DO NOT use electrical or pneumatic tools for tightening
the screws.
This submerged suction outlet is rated for floor (horizontal) installations ONLY.
810-0219-2017.0621
©2021 Waterway Plastics
Flow Rate (GPM)
664.0
1008.0
2035.0
NSF Measure Total Head Loss ("Hg)
0.07
0.12
0.54
Pressure Tap located downstream of 2 schedule 40 10
"
elbows and an 8.25" length of straight 10" pipe.
825-2330
642-4760
TW020
682-2050
319-0020
642-4720 V
Using the bonding log shown, the stainless steel support shall be bonded according to NFPA 70, Article 680. The bonding connection and wire
shall not be bather-accessible when the SOFA is fully assemble and installed in the pool. The bonding connection provided shall not be located
within the SOFA flow path zone or where it may pose a hair entanglement/ entrapment hazard, nor prevent service access to suction piping.