background image

7

Insufficient Flow

Press RETURN to clear

Low Flow

Press RETURN to clear

Water Overheat

Press RETURN to clear

Heater Overheat

Press RETURN to clear

Potential Freeze

Press RETURN to clear

Plumbing Error

Press RETURN to clear

ERROR SCREENS:

Error caused when SENSOR 1 and  
SENSOR 3 have been plugged in incorrectly.  
Swap the SENSOR 1 and SENSOR 3 plug in  
controller to correct this problem.

Error caused by no water flow through heater  
or no water in heater. Check to be sure there is 
enough water flow through heater.

Check to be sure there is enough 
water flow through heater.

Wait for water temperature to cool down.  

Wait for water temperature to cool down.  
Check to be sure there is enough water  
flow through heater.
 

Error caused when SENSOR 1, 2, or 3 detects 
low temperature. JET will turn on automatically to 
protect plumbing from freezing. JET will shut down 
when all 3 SENSORS reach a desired temperature.

t

t

t

t

t

t

Sensor 1 Fault

Press RETURN to clear

Sensor 2 Fault

Press RETURN to clear

Sensor 2 Fault

Press RETURN to clear

Sensor 3 Fault

Press RETURN to clear

Sensor 3 Fault

Press RETURN to clear

Sensor 1 Fault

Press RETURN to clear

Check SENSOR 1 connection.

Check SENSOR 1 connection 

or replace SENSOR 1.

  Check SENSOR 2 connection.

Check SENSOR 2 connection  

or replace SENSOR 2.

  Check SENSOR 3 connection. 

Check SENSOR 3 connection  

or replace SENSOR 3.

t

t

t

t

t

t

1

1

2

2

3

3

Summary of Contents for NEO 1100

Page 1: ...STEM NEO 1000 CONTROL PANEL The new standard in Spa Control 810 1980 1218 2018 Waterway Plastics 2200 E Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 waterway waterwayplastics com w...

Page 2: ...properly installed CAUTION High voltage levels exist inside the control box and can cause injury or possibly electrocution To prevent premature control failure do not hose down flood or allow water to...

Page 3: ...ccessories The screen below from bottom left to right indicates LIGHT ON and JET 1 at low speed UP DOWN MENU RETURN LIGHT JET 1 12 34 pm 104 F 1 1 3 NEO 1100 CONTROL PANEL JET 1 12 34 pm 104 F 1 1 NEO...

Page 4: ...e of panel LIGHT JET 1 BLOWER JET 2 These accessories have timeout defaults from the manufacturer and will turn OFF automatically after the time has expired Default Timeout time for LIGHT is 60 minute...

Page 5: ...ED and LCD lights will turn back on and panel will Poll for water temperature ENTER SETTING SCREENS Press the MENU button to display a list of setup screens Use UP and DOWN to navigate between various...

Page 6: ...o unlock the Menu With PANEL LOCK highlighted press MENU to enter PANEL LOCK setting Use UP DOWN to select the desired setting and RETURN to confirm the setting and exit NO HEAT TIME set the time fram...

Page 7: ...emperature to cool down Wait for water temperature to cool down Check to be sure there is enough water flow through heater Error caused when SENSOR 1 2 or 3 detects low temperature JET will turn on au...

Page 8: ...WIRING DIAGRAM 777 WW00110 8...

Reviews: