SAVE THIS MANUAL

PLEASE MAKE IT AVAILABLE TO ALL OTHER SPA USERS

2

      

WARNING! 

Qualified Technician Required for Service and Installation

BASIC INSTALLATION AND CONFIGURATION GUIDELINES

•  Use minimum 6AWG copper conductors only.
•  Readily accessible disconnecting means to be provided at time of installation.
•  Permanently connected power supply.
•  Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) mounted at least  
  5’ (1.52M) from the inside walls of the spa/hot tub and in line of sight from the equipment compartment.
• CSA enclosure: Type 2
• Refer to Wiring Diagram inside the cover of the control enclosure.
• Refer to Installation and Safety Instructions provided by the spa manufacturer.

WARNING!

 

People with infectious diseases should not use a spa or hot tub.

WARNING!

 

To avoid injury, exercise care when entering or exiting the spa or hot tub.

WARNING!

 

Do not use a spa or hot tub immediately following strenuous exercise.

WARNING!

 

Prolonged immersion in a spa or hot tub may be injurious to your health.

WARNING!

 

Maintain water chemistry in accordance with the Manufacturers instructions. 

WARNING!

 

The equipment and controls shall be located not less than 1.5 meters horizontally from the spa or hot tub.

WARNING! GFCI OR RCD PROTECTION.

The Owner should test and reset the GFCI or RCD on a regular basis to verify its function. 

       WARNING! SHOCK HAZARD! NO USER SERVICEABLE PARTS.

Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power connection instructions. 
Installation must be performed by a licensed electrician and all grounding connections must be properly installed.

       CAUTION!

 

High voltage levels exist inside the control box and can cause injury or possibly electrocution. To prevent premature control failure do 

not hose down, flood or allow water to enter the control box.

SPA CONTROL SYSTEM

CAUTION! CSA COMPLIANCE

• Test the ground fault circuit interrupter before each use of the spa.
• Read the instruction manual.
• Adequate drainage must be provided if the equipment is to be installed in a pit.
• For use only within an enclosure rated CSA Enclosure 3.
• Connect only to a circuit protected by a Class A ground fault circuit interrupter  
  or residual current device.
• To ensure continued protection against shock hazard, use only identical  
  replacement parts when servicing.
• Install a suitably rated suction guard to match the maximum flow rate marked.

WARNING! 

• Water temperature in excess of 100°F may be injurious to your health.
• Disconnect the electric power before servicing. Keep access door closed.

ATTENTION! CSA CONFORMITÉ

• Toujours verifier l’efficacite du disjoncteur differentiel avant d’utiliser le bain.
• Lire la notice technique.
• Lorsque l’appareillage est installe dans une fosse, on doit assurer un  
  drainage adequat.
• Employer uniquement a l’interieur d’une cloture CSA Enclosure 3.
• Connecter uniquement a un circuit protege par un disjoncteur differentiel  
  de Class A.
• Afin d’assurer une protection permanente contre le danger de shock electrique,  
  lors de l’entretien employer seulement des pieces de rechange identiques.
• Les prises d’aspiration doivent etre equipees de grilles convenant au debit  
  maximal indique.

ADVERTISSEMENT! 

• Des temperatures de l’eau superieures a 38°C peuvent presenter un danger  
  pour la sante.
• Deconnecter du circuit d’alimentation electrique avant l’entretien. Garder la  
  porte fermer.

WARRANTY

For product registration visit: www.waterwayplastics.com.

For Warranty questions or claims please contact point of purchase.

Summary of Contents for NEO 1200

Page 1: ...STEM NEO 1000 CONTROL PANEL The new standard in Spa Control 810 1980 1218 2018 Waterway Plastics 2200 E Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 waterway waterwayplastics com w...

Page 2: ...properly installed CAUTION High voltage levels exist inside the control box and can cause injury or possibly electrocution To prevent premature control failure do not hose down flood or allow water to...

Page 3: ...ccessories The screen below from bottom left to right indicates LIGHT ON and JET 1 at low speed UP DOWN MENU RETURN LIGHT JET 1 12 34 pm 104 F 1 1 3 NEO 1100 CONTROL PANEL JET 1 12 34 pm 104 F 1 1 NEO...

Page 4: ...e of panel LIGHT JET 1 BLOWER JET 2 These accessories have timeout defaults from the manufacturer and will turn OFF automatically after the time has expired Default Timeout time for LIGHT is 60 minute...

Page 5: ...ED and LCD lights will turn back on and panel will Poll for water temperature ENTER SETTING SCREENS Press the MENU button to display a list of setup screens Use UP and DOWN to navigate between various...

Page 6: ...o unlock the Menu With PANEL LOCK highlighted press MENU to enter PANEL LOCK setting Use UP DOWN to select the desired setting and RETURN to confirm the setting and exit NO HEAT TIME set the time fram...

Page 7: ...emperature to cool down Wait for water temperature to cool down Check to be sure there is enough water flow through heater Error caused when SENSOR 1 2 or 3 detects low temperature JET will turn on au...

Page 8: ...WIRING DIAGRAM 777 WW00110 8...

Reviews: