NEOTP500 SETTING SCREENS
(continued)
7
BACKGROUND SETTING:
allows user to set one of the 6 backgrounds for the spa application
CLEANER CYCLE SETTING:
sets the duration and
starts the additional filtration period after using the spa.
Only available for Non-Circs configurations.
GENERAL INFORMATION:
displays Panel Version, Controller Version, Configuration, and pump connections.
Please have this information ready for technical calls.
SPECIAL TEMPERATURE SELECTION:
allows the user to temporarily set the spa to higher than maximum set
temperature for Therapy.
SERENITY MODE:
Start/Stop Serenity Mode by turning off all outputs and provides quite time while in the spa. Duration is set
when this mode is selected.
DEMO MODE:
starts Demo Mode to demonstrate all device capabilities of the spa.
SERVICE MODE:
available only for Authorized Dealers and Spa Manufacturer. Please contact your Dealer or Spa Manufacturer
for additional information or support.
SYSTEM SETTING:
set system settings such as Wi-Fi connection, font size, and other aspects of the Android system.
MOBILE APP DEVICE REGISTRATION:
allows registration of the system so users can operate the spa with the Spa Mobile App.
ERROR CODES
(Shown on top of Main Menu screen)
Sensor 1 Open
:
Check SENSOR 1 connection.
Sensor 1 Short
:
Check SENSOR 1 connection or replace SENSOR 1.
Sensor 2 Open
:
Check SENSOR 2 connection.
Sensor 2 Short
:
Check SENSOR 2 connection or replace SENSOR 2.
Sensor 3 Open
:
Check SENSOR 3 connection.
Sensor 3 Short
:
Check SENSOR 3 connection or replace SENSOR 3.
PLUMBING ERROR:
Error caused when SENSOR 1 and SENSOR 3 have been plugged in incorrectly. Swap the SENSOR 1 (JP6) and SENSOR 3
(JP8) plugs in the controller to correct this problem.
INSUFFICIENT FLOW:
Error caused by no water flow through heater or no water in heater. Check to be sure there is enough water flow
through heater.
LOW FLOW:
Check to be sure there is enough water flow through heater.
WATER OVERHEAT:
Wait for water temperature to cool down.
HEATER OVERHEAT:
Wait for water temperature to cool down. Check to be sure there is enough water flow through heater.
POTENTIAL FREEZE:
Error caused when SENSOR 1, 2, or 3 detects low temperature. All JETS and BLOWERS will turn on
automatically to protect plumbing from freezing. JETS and BLOWERS will shut down when all 3 sensors reach a desired temperature.