USING THE WATERWISE 3200 DISTILLER

 

 

  Operational maintenance and replacement requirements are essential for    

 

 

  this product to perform as advertised.

 

 

    1.   Set Distiller on a dry, level, well-supported, stable surface.

 

 

    2.  Provide adequate air space (at least 4 inches from walls or cabinets)  

 

 

 

      around the distiller for proper cooling/ventilation. 

 

 

 

    3.   Rinse kettle thoroughly before filling to “MAX” lines with

 

 

      approximately 1 gallon of ordinary tap water. DO NOT fill above  

 

       “MAX” fill lines (fig. C). 

 

 

 

 

    4.   Replace kettle cover. Twist clockwise to lock. Slide kettle into base unit   

 

 

      and press firmly to ensure kettle is properly placed (fig. A).

 

 

    5.   Slide carafe into base unit.

 

 

    6.  Plug power cord into a grounded 120-volt outlet.

 

 

    7.   Press the “Reset” button on the kettle to turn Distiller ON (fig. A). The   

 

 

      “Indicator” light will illuminate. The cooling fan will not start immedi-  

 

 

      ately because of a delayed fan start-up feature. The fan will start once    

 

 

      the kettle has reached a predetermined temperature, approximately 30

  

 

      minutes after starting the cycle. The cooling fan will continue to operate

  

 

      approximately 1 minute after kettle turns off. When cycle is complete    

 

 

      (approximately four hours for 1 gallon), Distiller turns off automatically.

   

WARNING:  Never remove the kettle while the fan motor is running

 

 

  or for 30 minutes after a completed cycle. If cycle is interrupted, restart   

 

 

  and allow cycle to complete or wait at least 5 hours before removing the   

 

 

  kettle to allow water to cool.

 

 

    8.   Discard first gallon of distilled water as it may contain some harmless    

 

 

      matter from manufacturing and/or packaging.

 

 

    9.   To pour water from carafe, open spout by pulling on center strip in  

 

 

 

      direction of arrow indicator near thumb position.

 

 

   10.  Purified, distilled water may be stored in carafe in the refrigerator, if    

       preferred.
 

Waterwise 3200 Use & Care Guide

  

7

Figure 

C

“MAX” Fill Lines

Kettle Cover

(Bottom

View)

Kettle

Gasket

Kettle

Summary of Contents for 3200

Page 1: ...ortant operating safety and maintainance instructions in the literature accompanying the appliance A lightning bolt within an equilateral triangle is intended to alert user to risk of injury from elec...

Page 2: ...eri ence and knowledge unless they have been given supervision or in struction concerning use of the appliance by a person responsible for their safety DO NOT allow children near the Distiller without...

Page 3: ...ined temperature approximately 30 minutes after starting the cycle The cooling fan will continue to operate approxi mately 1 minute after kettle turns off 11 The Distiller requires no special care oth...

Page 4: ...compounds and is then collected in the Tritan collector serving carafe which is Bisphenol A BPA free 6 Tritan is a Trademark of Eastman Chemical Company arranged so that it will not drape over the co...

Page 5: ...TANT DO NOT immerse power cord kettle or base unit in water or liquid to avoid fire electrical shock and injury to persons Clean Kettle 1 Remove kettle from base unit 2 Remove kettle cover by twisting...

Page 6: ...illed or boiled tap water 4 Slowly immerse a narrow end of the filter bag into the water 5 Once the bottom quarter 1 4 is wet slowly immerse entire bag squeezing gently to remove air If the bag puffs...

Page 7: ...edi ately because of a delayed fan start up feature The fan will start once the kettle has reached a predetermined temperature approximately 30 minutes after starting the cycle The cooling fan will co...

Page 8: ...remove deposits You may also use a diluted solution of one cup white vinegar to every two cups of water DO NOT operate Distiller with cleaning solution in boiler tank Allow cleaning solution to stand...

Page 9: ...ot fill kettle with water to MAX lines 2 Carafe is not in correct position 3 Kettle cover is not locked into position 4 Kettle gasket damaged or missing 5 Kettle has accumulated residue scale buildup...

Page 10: ...ons CPAP Humidifiers no damaging scale buildup means longer product life Personal Hygiene contact lenses rinse free of irritating residue and distilled water is highly recommended for use with your Ne...

Page 11: ...Serial Number Date Purchased Purchased From FILTER REPLACED...

Page 12: ...connection with the use or performance of the product or other damages with respect to loss of use It is the responsibility of the user to ensure this product is installed in a location and used in a...

Reviews: