                                            INSTALLATION AND SERVICE INSTRUCTIONS

 

4211-1661   Rev A 

01/28/2022 

Page 

1

 of 

17

 

 

 
 
 

  
 
 

 

 

 

 

 

 

 
 
 

 

 

ATMOS STEAM GENERATORS 

WWSU08, WWSU11 AND WWSU15  

I

nstructions for 208V and 240V 1/3 Phase Models.

 

(Use 240V models for 400-415V~N3 installations) 

FOR USE WITH WWSU46 CONTROL PACKAGE 

 

Package includes: Exterior Control, Interior Control, control 
cables and a steam head. 

 

SAVE THESE INSTRUCTIONS 

 
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.

 

 

POST SAFETY "WARNING" LABEL OUTSIDE STEAMBATH. LABEL 
SHOULD BE POSTED ON OR ADJACENT TO DOOR TO STEAM 
ROOM IN COMMERCIAL INSTALLATIONS. 

 

SECTION  1:  GENERAL  INFORMATION 

 

Waterworks’ steam generators are tested by Intertek-ETL Laboratory. The steam generators come assembled and ready for 
installation. Check that the size and rating of the generator is suitable for your application, refer to the Steam Room Construction 
and Generator Guide (Waterworks doc. 4211-36). 
 
These steamers may be connected as a ganged system where one steamer controls one or two other steamers. Bath controls 
connect to the primary steamer and the primary steamer connects to the second steamer (and third steamer, if installed). This 
provides more power for large rooms and light commercial use. 

See appendix to this document for details. 

We recommend 

choosing steamers which are closely matched in power. The highest kW steamer should be the primary unit. Each steamer 
should have its own automatic drain.  
 
For commercial use, we recommend checking with your local inspectors to confirm the steamer system is acceptable for your 
use. Many jurisdictions will require an ASME boiler for commercial use: WATERWORKS steamers are not boilers. 
 

Note

: These steamers may be configured for single or three phase power during installation. 

 

IMPORTANT 

An exhaust fan installed outside the steam room is strongly  
recommended to remove excess steam from the bathroom or  
shower area.

 

 

 
 

          CAUTION 

 

 

Electrical grounding is required on all 

WATERWORKS Steam bath Generators. 

 

All electrical supplies should be 

disconnected when servicing generator. 

 

All wiring must be installed by a licensed 

electrical contractor in accordance with 

local and national codes. 

 

All plumbing must be installed by a 

licensed plumber in accordance with all 

applicable local and national codes. 

 

Steam generators are 

for indoor use only. 

 

Steam generators are not for 

space heating purposes. 

 

Be certain that steam bath enclosures 

are properly sealed to avoid water 

damage from escaping steam. It is 

recommended that 100% silicone caulk 

be used to seal all pipes and fittings. 

Steam must be prevented from escaping 

into the wall cavity. 

 

Never shut off the water to a 

steam generator that is in use. 

 

Electric Shock Hazard - High voltage 

exists within this equipment.  There 

are no user serviceable parts in this 

equipment.

 

STEAM HEAD 

STEAM GENERATOR 

EXTERIOR CONTROL 
(K3) 

INTERIOR CONTROL 
(KT3) 

Summary of Contents for WWSU08

Page 1: ...teamer should be the primary unit Each steamer should have its own automatic drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for y...

Page 2: ...age Important Safety Instruction 3 6 1 Mounting the Generator 7 8 2 Water Quality Requirements 8 3 Plumbing Instructions 9 12 4 Wiring Instructions 12 Electrical Information Chart 13 5 Bath Control In...

Page 3: ...ng must be installed by a licensed plumber in accordance with all applicable local and national codes Install indoors only Protect from freezing Generator must be level side to side and end to end The...

Page 4: ...erie doit tre install par un plombier sous licence conform ment tous les codes locaux et nationaux applicables Installer l int rieur uniquement Prot ger du gel G n rateur doit tre mise niveau lat rale...

Page 5: ...ERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 5 of 17 POST WARNING LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS tiquette d avertissement Ext rieur poste baiin de vapeur pour les avertissements re...

Page 6: ...utilis par toute personne y compris les enfants avec toutes leurs capacit s physiques sensorielles ou mentales ou qui manquent d exp rience ou de connaissances moins qu ils aient la supervision ou de...

Page 7: ...ervice Provide clearance for plumbing and electrical service and for element removal See Diagram 1 6 The steam line should slope to allow condensation to drain The mounting location should minimize th...

Page 8: ...ale to form on the internal surfaces This deposit or scale can interfere with the equipment s proper operation and even cause premature boiler or generator failure Concentration of impurities is gener...

Page 9: ...ator to allow for future servicing if needed and for emergency shut off Make sure the shut off is open providing water to the generator before turning it on IMPORTANT Water pressure required 20 100 ps...

Page 10: ...5 mm hole for the steam line entry Center the 1 2 copper steam pipe in the hole See Diagram 4 Terminate the steam line with a 1 2 NPT male adapter Stub the line out into the room 3 8 9 5 mm from the f...

Page 11: ...t have a drain valve installed to allow draining the tank for cleaning and maintenance A manual ball valve is supplied An electronic ball valve is available in the ADK Autodrain option When installed...

Page 12: ...dicated on the wire diagram for your voltage and phase This may require moving factory installed jumper Do not change the steamer s internal jumpers or wiring Only the supply wiring side of the termin...

Page 13: ...240 208 230 240 WWSU08 208 36 50 240 30 31 40 40 WWSU11 208 18 36 30 50 240 44 46 60 60 WWSU15 208 24 42 30 60 240 20 36 21 38 30 50 30 50 Nominal Amps at operating VAC 3 phz Recommended Breaker Mode...

Page 14: ...room The K3 and KT3 controls have a short tube on the back to help locate the control and to protect the cable end All of these controls connect to the steam generator s circuit board through Waterwor...

Page 15: ...or leaks 2 After the tank has filled to a safe level the heating elements will turn on Allow about 10 minutes for the steam to appear in the steam room 3 Once the steam is visible use the control to t...

Page 16: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 16 of 17...

Page 17: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 17 of 17 240V MODELS 208V MODELS...

Page 18: ...drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for your use Many jurisdictions will require an ASME boiler for commercial use WA...

Page 19: ...ION continued IMPORTANT Before deciding on a mounting location please read through these installation instructions completely and take a careful look at al of the diagrams An exhaust fan installed out...

Page 20: ...YPICAL DRAIN LINES DIAGRAM 5 TYPICAL STEAM LINES IMPORTANT Input water pressure must be 20 100 psi 138 689 kPa If the generators are mounted in a place difficult for the home owner to access the water...

Page 21: ...instructions document 4211 1661 for details regarding plumbing of the individual steamers in your system INSTALL THE PRESSURE RELIEF VALVE Each steamer must have its own pressure safety valve 10psi 69...

Page 22: ...Refer to the wiring diagrams to determine your connection points and the necessary jumper connection Connections can be varied to use either single phase or 3 phase or 3 phase Neutral Connect the eart...

Page 23: ...s the ON OFF switch 6 Within one minute the units should again produce steam The generators should call for water once every two minutes or more depending on their power rating It s normal for the flo...

Page 24: ...TERIORCONTROLISMOUNTEDOUTSIDETHEENCLOSURETO ALLOW FOR EASY ADJUSTMENTS TO THE TIME AND TEMPERATURE STEAMBATH SCHEDULE THE INTERIOR CONTROLIS MOUNTED INSIDE THE ENCLOSURE TO ALLOW TEMPERATURE SENSING A...

Page 25: ...Description Page Important Safety Instructions 3 1A Exterior Control Overview 4 1B Interior Control Overview 4 2 Operation of Your WWSUP18 and WWSUP19 Controls 4 3 How toTake a Steambath 4 4 Maintena...

Page 26: ...hould consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a phy...

Page 27: ...The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds 4 To change the time setting press and hold the TIME button on the cont...

Page 28: ...emperature adjustment needs setting 1 See Section 3 Temperature Adjustment 2 Call WATERWORKS Service Department Control ON exterior or interior Control displays E001 Temperature sensor not connected 1...

Page 29: ...4209 55 REV A 01 28 2022 WWSU46 OWNERS MANUAL page 6...

Reviews: