SECTION 5:  TROUBLE SHOOTING GUIDE

The troubleshooting guide is meant as a general aid only.  There are no user serviceable parts in the generator.  All repairs should be performed by a qualified service 

person. For additional assistance or the factory authorized service person nearest you call:  WATERWORKS Service Department at 1-800-927-2120.

SYMPTOMS

PROBABLE CAUSES

ACTION TO BE TAKEN

Control won't turn "ON"

(Control light off).

Improper power supplied (no power).

or

Control improperly connected.

  or 

Control cable is faulty.

or                         

Contol is faulty.

1. a. Make sure circuit breaker is "ON".

    b. Using a voltmeter, check the voltage across the two fuses on the "PCA"

        printed circuit assembly. Voltage should be 208V to 240V.        

    c. Check fuses on the PCA. If fuse(s) are blown, replace with Buss#

        MDL 15/100 or equivalent fuse. If the fuse blows again - call

       WATERWORKS Service Department.

2. Check control(s) installed per Section 6-5 in the INSTALLATION AND

    SERVICE INSTRUCTIONS.

3. Replace control cable - call WATERWORKS Service Department.

4. Replace the control - call WATERWORKS Service Department.

Control "OFF". 

Unit still makes steam.

Generator is faulty.

1.  Turn off the circuit breaker.

2.  Call WATERWORKS Service Department.

Water runs out of steam head.

Generator is faulty.

1.  Turn off the circuit breaker.

2.  Turn off the water.

3.  Call WATERWORKS Service Department.

Steam room too hot or cold.

Temperature adjustment needs 

setting.

1.  See Section 3, "Temperature Adjustment".

2.  Call WATERWORKS Service Department.

Control "ON",

exterior or interior 

Control displays "E001".

Temperature sensor not connected. 1. Check that the sensor cable is connected to J4 on the PCA printed circuit  

    assembly.

2. Check the cable connection to the temperature sensor.

3. Replace sensor and/or cable - call WATERWORKS Service Department.

Control "ON",

exterior or interior

Control displays "E002".

Temperature sensor.

 or

 Cable shorted.

1. Check sensor cable for damage from nail/staple puncture.

2. Check sensor cable ends for frayed/exposed wire strands.

3. Replace sensor and/or cable - call WATERWORKS Service Department.

Control "ON",

exterior or interior

Control displays ">>>º".

Steambath temperature over 132 º.

or

Sensor/cable is faulty.

1. If bath is too hot, shut off circuit breaker and call WATERWORKS Service  

    Department.

2. Treat as "E002" fault above.

Control won't turn "OFF".

(Control light on).

Control is faulty.

1. Replace the control - call WATERWORKS Service Department.

Control "ON" (Control display 

lit), unit won't steam. (Time/

Temp properly displayed 

 on Controls)

Unit has not filled completely.

or

Generator is faulty.

1. Wait at least 10 minutes after turning on the control.

2.  Call WATERWORKS Service Department.

Unable to adjust Time or Temp 

settings with exterior or interior 

Control.

Control is faulty.

or 

Generator is faulty.

1. Replace control - call WATERWORKS Service Department.

2. Replace PCA - call WATERWORKS Service Department.

Sudden increases in rate water 

sputters out of steam head.

Foaming contaminants 

in the water supply.

1.  Flush tank 3 times.  See Section 4.

Summary of Contents for WWSU08

Page 1: ...teamer should be the primary unit Each steamer should have its own automatic drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for y...

Page 2: ...age Important Safety Instruction 3 6 1 Mounting the Generator 7 8 2 Water Quality Requirements 8 3 Plumbing Instructions 9 12 4 Wiring Instructions 12 Electrical Information Chart 13 5 Bath Control In...

Page 3: ...ng must be installed by a licensed plumber in accordance with all applicable local and national codes Install indoors only Protect from freezing Generator must be level side to side and end to end The...

Page 4: ...erie doit tre install par un plombier sous licence conform ment tous les codes locaux et nationaux applicables Installer l int rieur uniquement Prot ger du gel G n rateur doit tre mise niveau lat rale...

Page 5: ...ERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 5 of 17 POST WARNING LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS tiquette d avertissement Ext rieur poste baiin de vapeur pour les avertissements re...

Page 6: ...utilis par toute personne y compris les enfants avec toutes leurs capacit s physiques sensorielles ou mentales ou qui manquent d exp rience ou de connaissances moins qu ils aient la supervision ou de...

Page 7: ...ervice Provide clearance for plumbing and electrical service and for element removal See Diagram 1 6 The steam line should slope to allow condensation to drain The mounting location should minimize th...

Page 8: ...ale to form on the internal surfaces This deposit or scale can interfere with the equipment s proper operation and even cause premature boiler or generator failure Concentration of impurities is gener...

Page 9: ...ator to allow for future servicing if needed and for emergency shut off Make sure the shut off is open providing water to the generator before turning it on IMPORTANT Water pressure required 20 100 ps...

Page 10: ...5 mm hole for the steam line entry Center the 1 2 copper steam pipe in the hole See Diagram 4 Terminate the steam line with a 1 2 NPT male adapter Stub the line out into the room 3 8 9 5 mm from the f...

Page 11: ...t have a drain valve installed to allow draining the tank for cleaning and maintenance A manual ball valve is supplied An electronic ball valve is available in the ADK Autodrain option When installed...

Page 12: ...dicated on the wire diagram for your voltage and phase This may require moving factory installed jumper Do not change the steamer s internal jumpers or wiring Only the supply wiring side of the termin...

Page 13: ...240 208 230 240 WWSU08 208 36 50 240 30 31 40 40 WWSU11 208 18 36 30 50 240 44 46 60 60 WWSU15 208 24 42 30 60 240 20 36 21 38 30 50 30 50 Nominal Amps at operating VAC 3 phz Recommended Breaker Mode...

Page 14: ...room The K3 and KT3 controls have a short tube on the back to help locate the control and to protect the cable end All of these controls connect to the steam generator s circuit board through Waterwor...

Page 15: ...or leaks 2 After the tank has filled to a safe level the heating elements will turn on Allow about 10 minutes for the steam to appear in the steam room 3 Once the steam is visible use the control to t...

Page 16: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 16 of 17...

Page 17: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 17 of 17 240V MODELS 208V MODELS...

Page 18: ...drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for your use Many jurisdictions will require an ASME boiler for commercial use WA...

Page 19: ...ION continued IMPORTANT Before deciding on a mounting location please read through these installation instructions completely and take a careful look at al of the diagrams An exhaust fan installed out...

Page 20: ...YPICAL DRAIN LINES DIAGRAM 5 TYPICAL STEAM LINES IMPORTANT Input water pressure must be 20 100 psi 138 689 kPa If the generators are mounted in a place difficult for the home owner to access the water...

Page 21: ...instructions document 4211 1661 for details regarding plumbing of the individual steamers in your system INSTALL THE PRESSURE RELIEF VALVE Each steamer must have its own pressure safety valve 10psi 69...

Page 22: ...Refer to the wiring diagrams to determine your connection points and the necessary jumper connection Connections can be varied to use either single phase or 3 phase or 3 phase Neutral Connect the eart...

Page 23: ...s the ON OFF switch 6 Within one minute the units should again produce steam The generators should call for water once every two minutes or more depending on their power rating It s normal for the flo...

Page 24: ...TERIORCONTROLISMOUNTEDOUTSIDETHEENCLOSURETO ALLOW FOR EASY ADJUSTMENTS TO THE TIME AND TEMPERATURE STEAMBATH SCHEDULE THE INTERIOR CONTROLIS MOUNTED INSIDE THE ENCLOSURE TO ALLOW TEMPERATURE SENSING A...

Page 25: ...Description Page Important Safety Instructions 3 1A Exterior Control Overview 4 1B Interior Control Overview 4 2 Operation of Your WWSUP18 and WWSUP19 Controls 4 3 How toTake a Steambath 4 4 Maintena...

Page 26: ...hould consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a phy...

Page 27: ...The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds 4 To change the time setting press and hold the TIME button on the cont...

Page 28: ...emperature adjustment needs setting 1 See Section 3 Temperature Adjustment 2 Call WATERWORKS Service Department Control ON exterior or interior Control displays E001 Temperature sensor not connected 1...

Page 29: ...4209 55 REV A 01 28 2022 WWSU46 OWNERS MANUAL page 6...

Reviews: