background image

Page 1

Safety Information

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

AVOIDING THE RISK TO CHILDREN

DANGER:

• R

RIIS

SK

K  O

OF

F  C

CH

HIILLD

D  D

DR

RO

OW

WN

NIIN

NG

G.. Extreme caution must be exercised to prevent unauthorized access by children.  To avoid accidents,

ensure that children cannot use a spa unless they are supervised at all times.

WARNING:

• To reduce the risk of injury, do not permit children to use this spa unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

DO:

• Make sure you always lock the child resistant locks after using the spa for your children’s safety. Every Hot Spring

®

spa is equipped with a

locking cover that meets the ASTM F1346-91 Standard for Safety Covers.

• Test the water temperature with your hand before allowing children to enter the spa to be sure that it’s comfortable. Children are

especially sensitive to hot water.

• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering, or exiting the spa.

DON’T:

• Allow children to climb onto the spa cover.
• Allow children to have unsupervised access to the spa.

AVOIDING THE RISK OF ELECTROCUTION

Risk of electrocution

• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type

cable is not used, or if improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG

(6 mm

2

) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical

equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.

WARNING:

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury

due to electrocution.

• Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection.  To ensure proper operation of this

important safety device, test according to the following instructions per electrical configuration.
C

Co

orrd

d--C

Co

onnnneecctteed

d  111155  vvo

olltt,,  2200  aam

mp

p  m

mo

od

deellss:: The GFCI is located at the end of the power cord. Before each use, with the unit operating,

push the TEST button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI
by pushing the RESET button. The GFCI power indicator will turn on, restoring power to the spa. If the interrupter does not perform in this
manner, there may be an electrical malfunction and with it, the possibility of an electric shock. Disconnect the power until the problem has
been corrected.
223300  vvo

olltt,,  p

peerrm

maanneennttllyy  iinnssttaalllleed

d  o

orr  cco

onnvveerrtteed

d  m

mo

od

deellss::

• A ground terminal is provided on the terminal block (TB-1, system ground terminal) located inside the control box. To reduce the risk of

electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated
copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal
(pressure wire connector) is provided on the outside of the control box for bonding to local ground points. To reduce the risk of electric
shock, this connector should be bonded with a No. 10 AWG (6 mm

2

) solid copper wire to any metal ladders, water pipes, or other metal

within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be
installed at least 5 feet (1.5 m) from the spa.

• Your spa is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.

Summary of Contents for Hot Spring

Page 1: ...Owner sManual...

Page 2: ...____________ TELEPHONE ________________________________________________________________________________________________________________ SPA MODEL SERIAL NUMBER ________________________________________...

Page 3: ...del AC 41 PRODIGY Model H 42 JETSETTER Model JJ 43 JETSETTER Model J 44 CONTROL PANEL OPERATIONS Control Panels 44 Main Control Panels 45 Indicator Lights 45 Locking Features 45 Main Control Panel But...

Page 4: ...o reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due to electrocution Your spa is provided with a Ground Fault C...

Page 5: ...verheating of the jet pump motor and motor damage Attempt to open the electrical control box There are no user serviceable parts inside RISKS TO AVOID DANGER RISK OF INJURY To reduce the risk of injur...

Page 6: ...uch as 5 F 2 C Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN Each Hot Spring spa is shipped with a SAFETY SIGN in the owner s package The sign which is...

Page 7: ...olt 50 amp Single phase GFCI protected circuit Jetsetter Model JJ 29 74 m 90 square feet 1 500 or 6 000 225 gallons 851 litres 450 lbs 204 kg 2 828 lbs 1 283 kg 90 lbs per square foot 115 volt 20 amp...

Page 8: ...the spa on the ground even temporarily place stepping stones under the leveling areas see Spa Leveling Instructions The stones should be at least two inches thick and twelve inches square Even with st...

Page 9: ...osite end resting on the lowest corner gently raise the lower end of the level by placing shims between the spa shell and the level until the level itself is level This will tell you how many shims ar...

Page 10: ...sure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 21 1 4 54 cm 20 50 8 cm 20 50 8 cm 20 1 4 56 5 cm 89 226...

Page 11: ...making critical design or pathway decisions 18 45 7cm 18 45 7cm 43 1 2 110 5cm 43 1 2 110 5cm 87 221cm 20 3 4 52 7cm 20 3 4 52 7cm 20 50 8cm 20 50 8cm 87 221cm 15 leveling points place shims approx 18...

Page 12: ...Page 9 SOVEREIGN MODEL I II Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edg...

Page 13: ...measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 20 1 4 51 4 cm 16 5 8 42 3 cm 16 5 8 42 3 cm 20 1 4 5...

Page 14: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims I...

Page 15: ...critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims Installation Instructions 84 2 13 m 80 2 03 m U P S I D E D O W N V I E W O F S P A...

Page 16: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims...

Page 17: ...system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Water feature lever E Hydromassage jet with directional nozzle F Hydromassage jet with rot...

Page 18: ...ion jets K Soothing Seven jets L JetStream jet M Heater return and spa drain N Light lens O Filter compartment P Main control panel Q Auxiliary control panel R Water Feature Model GG only S Water Feat...

Page 19: ...Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage DX jet H Precision jets I Soothing Seven jets J Je...

Page 20: ...n jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Moto Massage DX Jet I Precision jets J Soothing Seven...

Page 21: ...ol system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Precision jets I Soothing S...

Page 22: ...JetStream jet J Heater return and spa drain K Light lens L Filter compartment M Main control panel N Auxiliary control panel O Cup holder P Water feature Q Water feature lever 1 Wavemaster jet pump 2...

Page 23: ...system lever B JetStream jet Comfort Control system lever C Precision jets Comfort Control system lever D Hydromassage jet with directional nozzle E Hydromassage jet with rotary nozzle F Precision jet...

Page 24: ...JetStream jet Comfort Control system lever C Moto Massage DX jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydro...

Page 25: ...jet Comfort Control system lever C Moto Massage jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydromassage jet w...

Page 26: ...t of the control box Remove the screws and the control box cover 3 Route the electrical service from the subpanel into the spa equipment compartment Position the conduit in the recess provided between...

Page 27: ...UE wire from the subpanel 20 amp breaker terminal L1 to TB 1 terminal 1 3 Connect the 12 AWG RED wire from the subpanel 20 amp breaker terminal L2 to TB 1 terminal 3 N NO OT TE E The WHITE neutral wir...

Page 28: ...breaker switch to the ON up position If you don t wait 30 seconds the spa s control panel may flash four lines on and off try again If any of the GFCI breakers fails to operate in this manner your spa...

Page 29: ...rs to place the program jumpers as shown in Figure 2 use Watkins P N 36021 N NO OT TE E The program jumpers JP 1 JP 2 and JP 3 must be set correctly for the spa to operate Figure 2 illustrates the cor...

Page 30: ...tested prior to each use Here s how 1 Push the TEST button on each GFCI breaker and observe it click off 2 Wait 30 seconds then push the breaker switch to the OFF down position to ensure that it has c...

Page 31: ...d the National Electric Code When the spa is installed the power cord will come out of the bottom of the equipment compartment door For your safety when the electrician is installing the 20 amp single...

Page 32: ...ster 7000 jet pumps The Grandee GG uses one 2 0 HP Wavemaster 8000 and one 2 5HP Wavemaster 9000 single speed jet pump and the Envoy uses one 2 0 HP Wavemaster 8000 single speed and one 2 0 HP Wavemas...

Page 33: ...et system and to purge any remaining air from the heating system push the JETS button for the Vista Grandee and Envoy push the JETS 1 and JETS 2 buttons push the JETS 2 button a second time on the Vis...

Page 34: ...stem allows you to control the intensity of the massage at each jet by adjusting the mixture of air and water Jets with an adjustable faceplate are controlled by turning the faceplate clockwise for a...

Page 35: ...jets located in the FootWell are not adjustable HYDROSTREAM JET VISTA ENVOY ACCOLADE JETSETTER JJ SPAS ONLY The Hydrostream jet is a mid size hydromassage jet that delivers a great massage to the feet...

Page 36: ...onal Precision jets on right back wall 1 Moto Massage DX jet on right front 2 JetStream jets in FootWell system Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock position 6 HydroStream jet...

Page 37: ...s on back wall 1 JetStream jet in FootWell System 2 directional Precision jets on left seat calf area Jet Pump 2 Jet System 2 Right SmartJet lever in the 9 o clock position 1 Moto Massage jet on right...

Page 38: ...cision jets on left seat calf area 1 Moto Massage DX jet on right rear 4 directional Precision jets above right Moto Massage jet 2 directional Precision jets on right seat calf area Jet Pump 2 Jet Sys...

Page 39: ...n left seat calf area 4 HydroStream jets on right back wall 1 Moto Massage DX jet on right front wall 1 JetStream jet in FootWell System Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock p...

Reviews: