background image

Page 6

compromised immune system or respiratory infection. If you or other bathers are affected by this condition, please seek medical attention as soon as
possible.

In addition to the above, properly clean and maintain your spa as follows:

• Follow all procedures in this owner’s manual and printed instructions on all water care (chemical) products packaging.
• Test the water regularly to ensure proper levels of sanitizers, pH, and other water care requirements.
• Drain, clean, and refill your spa with fresh water on a regular schedule, and in accordance with this owner’s manual.
• Clean the filter(s) at least once per month.
• Check to make sure you have proper circulation throughout your spa water system.
• Have spa users bathe before entering the spa water.

SPA LEVELING INSTRUCTIONS

In order for your Hot Spring

®

spa to operate properly, and the internal plumbing to drain completely, the spa must be level. If the spa is to be

installed on an uneven, or unlevel foundation, shimming of the spa is required.

N

NO

OT

TE

E::  D

Duuee  tto

o  tthhee  llaarrg

gee  ssiizzee  o

off  tthhee  V

Viissttaa

®

®

aannd

d  G

Grraannd

deeee

®

®

ssp

paass,,  W

Waattkkiinnss  M

Maannuuffaaccttuurriinng

g  C

Co

orrp

po

orraattiio

onn  rreeq

quuiirreess  tthhaatt  tthheessee  ssp

paass  b

bee

iinnssttaalllleed

d  o

onn  aa  lleevveell  44””--  ((1100..11  ccm

m))  tthhiicckk  cco

onnccrreettee  p

paad

d  o

orr  ssttrruuccttuurraallllyy  eenng

giinneeeerreed

d  d

deecckk  aannd

d  N

NO

OT

T sshhiim

mm

meed

d  iinn  aannyy  m

maannnneerr..

W

WA

AR

RN

NIIN

NG

G::  Watkins Manufacturing Corporation recommends that a structural engineer or contractor be consulted prior to placing the spa

on an elevated deck, or platform. Use the Dead Weight in the Spa Specification chart to determine the structure’s requirements.

IIM

MP

PO

OR

RT

TA

AN

NT

T::  Watkins Manufacturing Corporation reserves the right to change any specifications or design without incurring any obligation.

Approved Shim Material

• Cedar shingles

• Exterior rated plywood

• Redwood

• Exterior rated lumber

The shims used should vary in thickness from 1/4 - to 1/2-inch (0.6 cm to 1.2 cm) and should be cut into 2” x 4” (5 cm x 10 cm) rectangles.

Leveling Instructions (Envoy

, Vanguard

®

, Sovereign

®

, Accolade

, Prodigy

®

and Jetsetter

®

models)

1. Using a 6’ (2 meter) carpenter’s level (or a shorter level and a straight 2” x 4”, 8’ board, or a board 5 cm by 10 cm, 2.4 meters long), check

the spa to identify the highest, and lowest corners.

2. With one end of the level resting on the highest corner of the spa (and the opposite end resting on the lowest corner), gently raise the

lower end of the level by placing shims between the spa shell and the level, until the level itself is level. This will tell you how many shims
are needed at that lowest corner.

3. Now carefully pivot the level, keeping the shimmed end where it is, until the other end of the level rests on one of the other corners. Check

the level. Adjust the end of the level using the procedure above. Carefully pivot the level again to the last corner, leaving the pivot end at its
original location, and repeat the procedure. Whatever shims are on the three corners are the ones you will place under those corners in the
next steps.

4. Remove the level and set it aside. Carefully remove the shims and keep them together, remembering the corner from which each set of

shims came.

5. With more than one person lifting, lift the lowest side of the spa (the one with the most shims), and place a 4” x 4” (10 cm x 10 cm) block

under the spa pedestal, at the center of the side lifted. 

6. Refer to the spa pedestal support diagram for your spa to locate the leveling points for the elevated corners. Place the set of shims

corresponding to each corner directly under its designated leveling point.

7. Lift the spa, remove the support block, and set the spa on the shims. Repeat steps 5 through 7, if necessary, for the opposite side of the

spa.

8. Use the level to check the level of the spa. Make any necessary adjustments.

9. Refer to the spa pedestal support diagram for your spa to locate the remaining leveling points, each of which must now also be shimmed,

and carefully slide “helper” shims under the spa at their designated locations. These helper shims should create a snug fit between the
foundation and the spa pedestal structure. If it is necessary to lift the spa in order to place the helper shims, use care not to kick out the
original corner shims.

The following base support diagrams for the Envoy, Vanguard, Sovereign, Accolade, Prodigy, and Jetsetter spas indicate the recommended
shimming points.

N

No

ottiiccee: Though designed for outdoor installation, your Hot Spring spa is not impervious to damage that may be caused by insects, rodents, or

other living creatures. A screen has been installed at the bottom of the door to minimize their ability to access the spa’s equipment
compartment and cause damage to the spa components. Please note, the electronics within the compartment need adequate airflow to cool
the equipment and maintain the optimal temperature range. Sealing the opening completely, or allowing debris to build-up on the screen
mesh, will adversely affect the spas’ performance. Damage to the spa or it’s components caused by an “act of nature”, rodent or insect
damage is not covered under the terms of your spa’s Limited Warranty.

Installation Instructions

Summary of Contents for Hot Spring

Page 1: ...Owner sManual...

Page 2: ...____________ TELEPHONE ________________________________________________________________________________________________________________ SPA MODEL SERIAL NUMBER ________________________________________...

Page 3: ...del AC 41 PRODIGY Model H 42 JETSETTER Model JJ 43 JETSETTER Model J 44 CONTROL PANEL OPERATIONS Control Panels 44 Main Control Panels 45 Indicator Lights 45 Locking Features 45 Main Control Panel But...

Page 4: ...o reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due to electrocution Your spa is provided with a Ground Fault C...

Page 5: ...verheating of the jet pump motor and motor damage Attempt to open the electrical control box There are no user serviceable parts inside RISKS TO AVOID DANGER RISK OF INJURY To reduce the risk of injur...

Page 6: ...uch as 5 F 2 C Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN Each Hot Spring spa is shipped with a SAFETY SIGN in the owner s package The sign which is...

Page 7: ...olt 50 amp Single phase GFCI protected circuit Jetsetter Model JJ 29 74 m 90 square feet 1 500 or 6 000 225 gallons 851 litres 450 lbs 204 kg 2 828 lbs 1 283 kg 90 lbs per square foot 115 volt 20 amp...

Page 8: ...the spa on the ground even temporarily place stepping stones under the leveling areas see Spa Leveling Instructions The stones should be at least two inches thick and twelve inches square Even with st...

Page 9: ...osite end resting on the lowest corner gently raise the lower end of the level by placing shims between the spa shell and the level until the level itself is level This will tell you how many shims ar...

Page 10: ...sure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 21 1 4 54 cm 20 50 8 cm 20 50 8 cm 20 1 4 56 5 cm 89 226...

Page 11: ...making critical design or pathway decisions 18 45 7cm 18 45 7cm 43 1 2 110 5cm 43 1 2 110 5cm 87 221cm 20 3 4 52 7cm 20 3 4 52 7cm 20 50 8cm 20 50 8cm 87 221cm 15 leveling points place shims approx 18...

Page 12: ...Page 9 SOVEREIGN MODEL I II Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edg...

Page 13: ...measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 20 1 4 51 4 cm 16 5 8 42 3 cm 16 5 8 42 3 cm 20 1 4 5...

Page 14: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims I...

Page 15: ...critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims Installation Instructions 84 2 13 m 80 2 03 m U P S I D E D O W N V I E W O F S P A...

Page 16: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims...

Page 17: ...system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Water feature lever E Hydromassage jet with directional nozzle F Hydromassage jet with rot...

Page 18: ...ion jets K Soothing Seven jets L JetStream jet M Heater return and spa drain N Light lens O Filter compartment P Main control panel Q Auxiliary control panel R Water Feature Model GG only S Water Feat...

Page 19: ...Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage DX jet H Precision jets I Soothing Seven jets J Je...

Page 20: ...n jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Moto Massage DX Jet I Precision jets J Soothing Seven...

Page 21: ...ol system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Precision jets I Soothing S...

Page 22: ...JetStream jet J Heater return and spa drain K Light lens L Filter compartment M Main control panel N Auxiliary control panel O Cup holder P Water feature Q Water feature lever 1 Wavemaster jet pump 2...

Page 23: ...system lever B JetStream jet Comfort Control system lever C Precision jets Comfort Control system lever D Hydromassage jet with directional nozzle E Hydromassage jet with rotary nozzle F Precision jet...

Page 24: ...JetStream jet Comfort Control system lever C Moto Massage DX jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydro...

Page 25: ...jet Comfort Control system lever C Moto Massage jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydromassage jet w...

Page 26: ...t of the control box Remove the screws and the control box cover 3 Route the electrical service from the subpanel into the spa equipment compartment Position the conduit in the recess provided between...

Page 27: ...UE wire from the subpanel 20 amp breaker terminal L1 to TB 1 terminal 1 3 Connect the 12 AWG RED wire from the subpanel 20 amp breaker terminal L2 to TB 1 terminal 3 N NO OT TE E The WHITE neutral wir...

Page 28: ...breaker switch to the ON up position If you don t wait 30 seconds the spa s control panel may flash four lines on and off try again If any of the GFCI breakers fails to operate in this manner your spa...

Page 29: ...rs to place the program jumpers as shown in Figure 2 use Watkins P N 36021 N NO OT TE E The program jumpers JP 1 JP 2 and JP 3 must be set correctly for the spa to operate Figure 2 illustrates the cor...

Page 30: ...tested prior to each use Here s how 1 Push the TEST button on each GFCI breaker and observe it click off 2 Wait 30 seconds then push the breaker switch to the OFF down position to ensure that it has c...

Page 31: ...d the National Electric Code When the spa is installed the power cord will come out of the bottom of the equipment compartment door For your safety when the electrician is installing the 20 amp single...

Page 32: ...ster 7000 jet pumps The Grandee GG uses one 2 0 HP Wavemaster 8000 and one 2 5HP Wavemaster 9000 single speed jet pump and the Envoy uses one 2 0 HP Wavemaster 8000 single speed and one 2 0 HP Wavemas...

Page 33: ...et system and to purge any remaining air from the heating system push the JETS button for the Vista Grandee and Envoy push the JETS 1 and JETS 2 buttons push the JETS 2 button a second time on the Vis...

Page 34: ...stem allows you to control the intensity of the massage at each jet by adjusting the mixture of air and water Jets with an adjustable faceplate are controlled by turning the faceplate clockwise for a...

Page 35: ...jets located in the FootWell are not adjustable HYDROSTREAM JET VISTA ENVOY ACCOLADE JETSETTER JJ SPAS ONLY The Hydrostream jet is a mid size hydromassage jet that delivers a great massage to the feet...

Page 36: ...onal Precision jets on right back wall 1 Moto Massage DX jet on right front 2 JetStream jets in FootWell system Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock position 6 HydroStream jet...

Page 37: ...s on back wall 1 JetStream jet in FootWell System 2 directional Precision jets on left seat calf area Jet Pump 2 Jet System 2 Right SmartJet lever in the 9 o clock position 1 Moto Massage jet on right...

Page 38: ...cision jets on left seat calf area 1 Moto Massage DX jet on right rear 4 directional Precision jets above right Moto Massage jet 2 directional Precision jets on right seat calf area Jet Pump 2 Jet Sys...

Page 39: ...n left seat calf area 4 HydroStream jets on right back wall 1 Moto Massage DX jet on right front wall 1 JetStream jet in FootWell System Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock p...

Reviews: