30 Amp Subpanel Wiring Instructions:
NOTE:
The subpanel must be placed within 100 feet of the main electrical service panel, and between 5 and 50 feet away from the
spa. Refer to the wiring diagram below. A 115 volt 30 amp subpanel may be purchased from your local Solana
®
dealer, ask for Part
# 37573 or # 37546.
A licensed electrician should install three-wire electrical service (one line voltage, one neutral, one ground) from the main electrical
service panel; to the subpanel.
The grounding conductor must be the same gauge as the line conductor, but at least #10 AWG. Your electrician should mount the
subpanel in the vicinity of the spa but it should not be closer than five (5) feet from the spa water edge (NEC 680-6c).
10
115VAC, 30 Amp
Single Pole
Circuit Breaker
(Non Gfci)
Main Service
Electrical
Panel
Less Than 100 FT.
Sub-Panel
with GFCI
Breakers
More than 5 feet
the Sub-Panel must be
within sight of the spa
Do Not Exceed 50 Feet
Control Box
N, Neutral, #10AWG White
L1, Hot, #10AWG Black
Ground, #10AWG Green
#10 AWG White, Neutral
#10 AWG Green, Ground
#10 AWG Black, L1
WIRING ILLUSTRATION
PERMANENTLY CONNECTED FOR
115 VAC, 24A, 60HZ, CONVERTED MODELS