5 - Error Conditions, Problems and Solutions - Change the Fuses
Océ BLM500 Operator Manual
47
CAUTION
Use a pencil, the blunt end of a pen or a palm top wand for this procedure. Do
not use a sharp object. Sharp objects damage the screen.
Procedure
1. Touch the STOP button
5 times.
2. Follow the instructions on the touch screen.
3. Touch
DONE
in the centre of the screen.
Change the Fuses
Introduction
The BLM500 has two fuses at the mains power input. If either fuse is broken,
the BLM500 will not operate.
WARNING
Turn OFF the machine and remove the mains power supply cable before you
change the fuses. This machine uses two fuses in parallel.
Fuse Description
• 7A, HRC Quick acting, F
• Part Number 730-018
Procedure
1. Turn OFF the BLM500.
2. Disconnect the BLM500 from the mains power supply.
3. Turn one fuse-holder to the left and remove the fuse-holder from the BLM500
4. Check the fuse.
5. If the fuse is broken then replace with a fuse of the correct specification.
6. Repeat the procedure for the other fuse.
Result
If the fuse breaks again, then call your service engineer.
Manually park the Shuttle
When to do
The error messages ‘MANUALLY PARK SHUTTLE’ and ‘SHUTTLE NOT
PARKED’ are displayed.