Product Overview
6
Plockmatic PowerSquare™ 224 - Service Training Workbook
Stage Description
Service Manual Reference
The fold blade lifts and the form clamp
closes. The form roller creates the
SquareBack spine on the book.
See Section 1.7.6.
The book is moved to the trim stop and
clamped in position. The fore-edge of the
book is trimmed by the trimmer blade that
moves horizontally.
See Section 1.7.7.
The book is released and conveyed by the
outfeed mechanism to the stacker.
See Section 1.7.8.
The finished books are stacked neatly,
ready for the operator to remove.
See Section 1.7.8.
Figure 2:1. End view of the
Plockmatic PowerSquare 224 showing
PSQ Site Requirements
Plockmatic PowerSquare™ 224 - Service Training Workbook
43
17.
PSQ Site Requirements
17.1
Environment
17.2
Floor surface and cover
• Only install the PSQ on a level floor.
• The PSQ needs a solid and durable floor. Deep pile carpet and thick,
cushioned underlays can cause problems when the PSQ is moved.
17.3
Access
• The PSQ is 755 mm wide and fits through a standard-size doorway. A
standard-size doorway is 762 mm (30") wide.
• If the PSQ is installed up or down stairs, give special consideration to how
you lift and move the equipment.
17.4
Space needed to unload the PSQ
• The PSQ is shipped on a bespoke pallet. The pallet includes ramps that are
used to unload the machine.
• An area of 1m x 6m (40" x 237"
)
is needed to unload the PSQ from the pallet.
17.5
Dimensions
Parameter
Value
Ambient Temperature
10-35°C (50-95°F)
Relative Humidity
35-85%
Altitude
up to 2000m amsl
PSQ
Width
Depth
Height
Online
PSQ
with stacker and
connecting bridge
1675 mm
66"
1870 mm
74"
1330 mm
52"
Pallets
Length
Width
Height
PSQ
2090 mm
83
"
940 mm
37
"
1480 mm
59
"
Connecting bridge
1180 mm
47
"
900 mm
36
"
1350 mm
54
"