PSQ Site Requirements
44
Plockmatic PowerSquare™ 224 - Service Training Workbook
17.6
Weight
17.7
Electrical
17.8
Printer Interface
A DFA interface cable is supplied with the online PSQ.
17.9
Floor Space
The floor space requirement is shown below.
PSQ
Weight
Online with connecting bridge and stitch-wire
532 kg, 1173-lb
Item
Specification
Supply
A single phase, earthed (grounded) power supply is
needed
Voltage
Adjustable to 200, 208, 220, 230 and 240V
Frequency
50/60Hz
Current
4.0A
Note: Startup peak value max 30A. A slow circuit breaker
of minimum 16A is required.
Protection Fuse
2 X F7.0A HRC
Mains
Connection
PSQ
connection : IEC60320 C19
Removable cable and plug supplied.
Europe : IEC83 'Shuko'
UK : BS 1363
North America / Japan : NEMA 6-15
For other areas, contact the supplier for the correct cable.
Power
Consumption
700VA (500W) maximum
Product Overview
Plockmatic PowerSquare™ 224 - Service Training Workbook
5
2.
Product Overview
2.1
Paper Path
Stage Description
Service Manual Reference
The sheets of paper leave the printer and
enter the infeed of the connecting bridge.
See Section 1.7.1.
The paper is rotated in the connecting
bridge if necessary.
See Section 1.7.1.
The sheets of paper are gathered into a set
in the gathering area. When a set is
complete it is collected by the shuttle.
See Section 1.7.2.
See Section 1.7.3.
The set is moved to the stitch head where
the set is stitched
See Section 1.7.4.
See Section 1.7.5.
The set is moved to the fold position where
the fold blade pushes the set into the spine
form clamp.
See Section 1.7.6.
FIGURE 4. Plan view of the Plockmatic PowerSquare 224 showing