165
•
Chapter 6 Appendix
Parameter Class
and Name
Range
Default
Data Type and
Attributes
Modbus Registers
Output Value 2
"IEEE Float
Access=R"
"Special Output
Function 1: 14718
Special Output
Function n: 14718+((n-
1)* 80)"
Error
"None (61)
Open (65)
Shorted (127)
Measurement Error (140)
Bad Calibration Data
(139)
Ambient Error (9)
RTD Error (141)
Fail (32)
Math Error (1423)
Not Sourced (246)
Stale (1617)"
"unsigned 16-bit
Access = R"
"Special Output
Function 1: 14720
Special Output
Function n: 14720+((n-
1)* 80)"
Output Value 3
"IEEE Float
Access=R"
"Special Output
Function 1: 14722
Special Output
Function n: 14722+((n-
1)* 80)"
Error
"None (61)
Open (65)
Shorted (127)
Measurement Error (140)
Bad Calibration Data
(139)
Ambient Error (9)
RTD Error (141)
Fail (32)
Math Error (1423)
Not Sourced (246)
Stale (1617)"
"unsigned 16-bit
Access = R"
"Special Output
Function 1: 14724
Special Output
Function n: 14724+((n-
1)* 80)"
Output Value 4
"IEEE Float
Access=R"
"Special Output
Function 1: 14726
Special Output
Function n: 14726+((n-
1)* 80)"
Error
"None (61)
Open (65)
Shorted (127)
Measurement Error (140)
Bad Calibration Data
(139)
Ambient Error (9)
RTD Error (141)
Fail (32)
Math Error (1423)
Not Sourced (246)
Stale (1617)"
"unsigned 16-bit
Access = R"
"Special Output
Function 1: 14728
Special Output
Function n: 14728+((n-
1)* 80)"
Input A Turn On
-100 To 100
0
"IEEE Float
Access=RW"
"Special Output
Function 1: 14730
Special Output
Function n: 14730+((n-
1)* 80)"