Watlow D4T Data Logger
•
210
•
Chapter 6 Appendix
Declaration of Conformity
Series (D or F) 4T
WATLOW Electric Manufacturing Company
ISO 9001
since 1996.
1241 Bundy Blvd.
Winona, MN 55987 USA
Declares that the following products:
Designation:
Series (D or F) 4T ¼ DIN Control
Model Numbers:
F4T X X (1 to 8) – X AA XX X – XXX
D4T X X (1 to 8) – X AA XX 5 – XXX X = any number or letter.
Classification:
F4T = Process Controller Base
D4T = Data logger
Both Models rated – Installation Category II,
IP65 or IP40 if flush mount option is used.
Rated Voltage and Frequency:
High Voltage 100 to 240 V~ (ac) 50/60 Hz, (D or F) 4TXX(1, 2, 3, 4)
Low Voltage 24 to 28 V (ac/dc) 50/60 Hz, (D or F) 4TXX(5, 6, 7, 8)
Rated Power Consumption:
Up to 23 Watts with six modules loaded.
Only the front display is considered part of the ultimate enclosure, the unit is considered an open type process control, it
requires an ultimate enclosure and at least one
W
atlow
EZ-ZONE
®
FM “Flex Module”
to have a useful function. All Flex Modules were
tested as part of F4T system for compliance with the following directives.
2014/30/EU Electromagnetic Compatibility Directive
EN 61326-1:2013
EN 55011:2016
Electrical equipment for measurement, control and laboratory use – EMC
requirements (Industrial Immunity, Group 1 Class A
1
Emissions).
IEC 61000-4-2:2008
Electrostatic discharge immunity
IEC 61000-4-3:2007 +
A1/2008, A2/2010
Radiated, radio-frequency electromagnetic field immunity, 10 V/m 80 MHz to 1 GHz, 3
V/m 1.4 GHz to 2.7 GHz
IEC 61000-4-4:2012
Electrical fast-transient / burst immunity
IEC 61000-4-5:2014
Surge immunity
IEC 61000-4-6:2013 +
Corrigendum 2015
Immunity to conducted disturbances induced by radio-frequency fields
IEC 61000-4-11:2004 +
Interpretation 2010
Voltage dips, short interruptions and voltage variations immunity
EN 61000-3-2:2014
Limits for harmonic current emissions for equipment ≤ 16 Amps per phase
EN 61000-3-3
2
:2013
Voltage fluctuations and flicker for equipment ≤ 16 Amps per phase
SEMI F47-0812
Specification for semiconductor sag immunity Figure R1-1
1
NOTE: Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio
reception in such environments.
2
NOTE: To comply with flicker requirements cycle time may need to be up to 160 seconds if load current is at 15A, or the maximum source
impedance needs to be < 0.13
Ω
. Unit power of F4T model complies with 61000-3-3 requirements.
2014/35/EU Low-Voltage Directive
EN 61010-1:2010
Safety Requirements of electrical equipment for measurement, control and
laboratory use. Part 1: General requirements
Compliant with 2011/65/EU RoHS2 Directive
Per 2012/19/EU W.E.E.E Directive and 2006-66-EC Battery Directive
Please Recycle Properly.
Joe Millanes
Winona, Minnesota, USA
Name of Authorized Representative
Place of Issue
Directory of Operations
October, 2016
Title of Authorized Representative
Date of Issue
Signature of Authorized Representative