Watlow EZ-ZONE
®
ST
•
89
•
Appendix
[`A;bL]
Alarm Blocking 49, 73
[AC;LF]
AC Line Frequency 52, 71
[A;dSP]
Alarm Display 50
[`A;hi]
Alarm High Set Point 35, 72
[`A;hy]
Alarm Hysteresis 49, 72
[``Ai]
Analog Input Menu 31, 40
[`A;iS]
Alarm Source Instance 49
[`A;LA]
[`A;Lg]
Alarm Logic 49
[ALM]
Alarm Menu 35, 48
[`A;Lo]
Alarm Low Set Point 35, 72
[`A;Sd]
Alarm Sides 49
[`A;Si]
[A;tSP]
Autotune Set Point 33, 65
[Attn]
[`A;ty]
Alarm Type 48, 72
[`AUt]
Autotune 33, 65
[bAUd]
Baud Rate 53
[bPLS]
[`C;Ag]
Cool Algorithm 44, 69
[`CAL]
Calibration Menu 63
[`C;Er]
Current Error 36
[`C_F]
Display Units 52, 53
[`C;hi]
Current High Set Point 36
[`C;hy]
Cool Hysteresis 34, 69
[`C;Lo]
Current Low Set Point 36
[`CLr]
[`C;M]
Control Mode 33, 69
[C;MA]
Control Mode Active 32
[Code]
Public Key 62
[Code]
Unlock Code 74
[CoM]
Communications Menu 53
[`C;Pb]
Cool Proportional Band 34,
[`C;Pr]
Cool Power 33, 65
[`C;SP]
Closed Loop Set Point 33
[`C;SP]
Closed Loop Working Set
[`CU;r]
Current Read 36
[CUrr]
Current Menu 36, 50
[CUSt]
Custom Setup 60
[dAtE]
Date of Manufacture 62
[``db]
[`dEC]
[diAg]
Diagnostics Menu 62
[`dio]
Digital Input/Output Menu
[`dir]
Direction 42
[`do;S]
Digital Output State 32
[d;prs]
Display Pairs 52
[`Ei;S]
Event Input Status 32
[ELi;o]
Electrical Input Offset 63, 67
[ELi;S]
Electrical Input Slope 63, 67
[ELo;o]
Electrical Output Offset 63
[ELo;S]
Electrical Output Slope 63
[`End]
[`End]
End Type 56
[Ent1]
Active Event Output 1 38
[Ent1]
[Ent2]
[FAiL]
Input Error Failure 45, 68
[``Fi]
Digital Output Function In-
[``Fi]
Output Function Instance 47
[`FiL]
Filter 41
[`FiL]
Filter Time 67
[``Fn]
Output Function 47, 48
[`FUn]
Function Key Menu 51
[gLbL]
Global Menu 52
[`gSd]
Guaranteed Soak Deviation
[`gSE]
Guaranteed Soak Enable 52
[`h;Ag]
Heat Algorithm 44, 69
[`h;Er]
Heater Error 36
[`h;hy]
Heat Hysteresis 34, 69
[hoUr]
Hours 55
[`h;Pb]
Heat Proportional Band 34,
[`h;Pr]
Heat Power 33, 65
[`h;SP]
Control Loop High Set Point
[`i;CA]
Calibration Offset 31, 66–67
[`id;S]
Idle Set Point 33
[`i;Er]
Input Error Latching 42
[`i;Er]
Input Error Status 31
[iP;F4]
IP Fixed Address Part 4 52
[``JC]
Jump Count 56
[``JC]
Jump Count Remaining 38
[``JS]
Jump Step 56
[`L;dd]
Open Loop Detect Deviation
[`L;dE]
Open Loop Detect Enable
[`L;dt]
Open Loop Detect Time 46
[`L;hy]
Limit Hysteresis 44
[Lim]
Limit Menu 32, 44
[`Lin]
Linearization 40
[`LL;S]
Limit Low Set Point 32
[`LoC]
Security Setting Menu 60,
[loC;l]
, Locked Access Level 74
[loC;L]
Locked Access Level 74
[loC;l]
Locked Access Level 61
[LoC;o]
Lock Operations page 73
[LoC;o]
Lock Operations Page 60,
[LoC;P]
Lock Profiling Page 61, 62,
[LooP]
Control Loop Menu 44
[LooP]
Loop Menu 33
[`L;Sd]
[`L;SP]
Loop Low Set Point 46
[MAn]
[MAn]
Manual Power 46
[M;hL]
Modbus Word Order 53
[Min]
Minutes 55
[Mon]
Monitor Menu 32
[`Mu]
Electrical Measurement 63,
[`nU;S]
Non-volatile Save 53
[`o;Ct]
Output Control 42, 47
[`o;Fn]
Output Function 66
[`o;hi]
Output High Power Scale
[`o;Lo]
Output Low Power Scale 43,
[``oP]
Open Loop Set Point 34
[`o;tb]
Output Time Base 43, 48
[otPt]
Output Menu 47
[`PAr]
Parity 53
[pas;a]
Administrator Password 62,
[pas;a]
, Administrator Password 74
[pas;e]
Password Enable 61
[pas;e]
Password Security Enable
[pass]
[pas;u]
[pas;u]
, User Password 74
[`P;EE]
Process Error Enable 41
[`P;EL]
Process Error Low 41
[P;StA]
Profile Status Menu 37
[P;tyP]
Profile Type 52
[`Pu;A]
Process Value Active 33
[rAtE]
Rate 55, 57
[`r;hi]
[`r;Lo]
Range Low 41, 42, 68
[rLoC]
Read Lockout Security 61,
[roll]
[roll]
, Rolling Password 74
[``rP]
Ramp Action 46, 71
[`r;rt]
Ramp Rate 46, 71
[`r;SC]
[`rt;L]
[S;bLd]
Software Build 62
[`SEC]
[`SEn]
Sensor Type 40, 66, 68
[SFn;A]
Source Function A 48
[`S;hi]
[`S;id]
Software ID 62
[`SiL]
[`S;Lo]
Scale Low 41, 68
[SLoC]
Set Lockout Security 61, 73
[``Sn]
[SP;hi]
Set Point High Limit Open
[SP;Lo]
Set Point Low Limit Open
[`S;rL]
Software Release 62
[ss;ti]
Soft Start Time 39, 48
Index