Watson Industries, Inc.
ADS-C232-3AD Rev A 10/25/2017
19
Appendix B.5 Set Baud Rate
1) To change the baud rate at which the sensor communicates, type ‘4’ at the main menu.
This will bring up the menu:
7) Change the baud rate to a new setting.
To change to 38,400 Baud, type ‘1’.
To change to 19,200 Baud, type ‘2’.
To change to 9,600 Baud, type ‘3’.
To change to 4,800 Baud, type ‘4’.
The baud rate change will take effect immediately. To make the new baud rate the default
setting, send a quote symbol (“) using the new baud rate. Otherwise the old baud rate will
return the next time the unit is powered up.
Note: The baud rate of the software that is communicating to the sensor will need to be changed
to match the new setting.
8) Press the space bar to resume data transmission.
The factory settings for serial communications are 9.6K baud with 8 bits and one stop bit, no parity.
TYPE IN THE NUMBER OF YOUR SELECTION (OR 'Q' TO QUIT):
(
EFFECTIVE IMMEDIATELY - SAVE TO MAKE PERMANENT)
1 = 38.4 K BAUD
2 = 19.2 K BAUD
3 = 9.6 K BAUD
4 = 4.8 K BAUD