If hazardous fluids are to be pumped, safety procedures specific to
the particular fluid and application must be put in place to protect
against injury to persons.
This product does not comply with the ATEX directive and must not be
used in explosive atmospheres.
Ensure the chemicals to be pumped are compatible with the
pumphead, lubricant (where applicable), tubing, pipework and
fittings to be used with the pump. Please refer to the chemical
compatibility guide which can be found at:
If you need to use the pump with any other chemical please contact
Watson-Marlow to confirm compatibility.
If the Auto restart feature is enabled it may cause the pump to start as
soon as power is turned on.
Auto-restart only affects operation of manual mode, network mode and
memodose mode.
If Auto restart is enabled the "!" Symbol is shown on the screen to
warn users that the pump may operate without any manual
intervention (pump resumes with previous settings).
Do not use auto restart for more than 20 mains power starts per hour.
We recommend remote control where a high number of starts is
required.
If the pump is configured to network mode or analog mode it will
respond to remote commands at any time including immediately after
power on. The "!" Symbol is shown on the screen to warn users that
the pump may operate without any manual intervention (e.g. a remote
setpoint could start the pump with no key press required).