2
Operating manual
2.5 Manual operation — 120S and 120U
2.6 Remote and automatic control and operation
2.1
Specifications
120F specifications
Control range
(turndown ratio)
Fixed speed:
With 102R: 10rpm; 17rpm; 31rpm
With 114DV: 10rpm; 17rpm; 31rpm; 52rpm; 220rpm
Power supply DC
input
24V @ 1A
Enclosure rating
IP31 to BS EN 60529. Equivalent to NEMA 2, suitable for indoor use. Protected
against dripping water and falling dirt. May be wiped with a damp cloth, but
should not be immersed
Pumphead
options
114DV and 102R
Tubing options
Pumpsil silicone tubing only
Operating
temperature
range
5C to 40C, 41F to 104F
Storage
temperature
range
-25C to 65C, -13F to 149F
Maximum
altitude
2,000m, 6,560ft
Humidity
(non-condensing)
80% up to 31C, 88F, decreasing linearly to 50% at 40C, 104F
Weight
See
Refer to "Dimensions" on page 14
Noise
<60dB(A)
m-120-en-02
16