background image

 

Page 6

 

Part 2: Operation 

Overview

 

Start the pump by turning the forward/off/reverse switch on the left hand side 

of the front panel to the required direction of rotation. The preferred direction 

of rotation is clockwise (with fluid entering at the bottom right of the 

pumphead and exiting at the top right of the pumphead), which will ensure the 

longest possible tube life. To operate against higher pressures, use 

anticlockwise rotation. The pump can be primed rapidly at its maximum speed 

by depressing the max switch on the front panel. When released the switch 

will return to its normal position.  
To stop the pump, turn the forward/off/reverse switch to its central off 

position. To change the direction of flow, turn the forward/off/reverse switch to 

its central off position until the pumphead rotor stops, and then turn it to the 

other direction of rotation.  
The speed control ratio of the 604S/R is 50:1 giving a speed range from 

approximately 4rpm to its rated maximum speed of 165rpm.  

Flow rates

 

The flow rates given below were obtained using Watson-Marlow 3.2mm wall 

thickness Marprene tubing pumping water at 20C with negligible suction and 

delivery pressures (unless otherwise stated). Where an application is critical, 

the flow rate should be determined under operating conditions. The important 

factors are suction and delivery pressures, temperature and fluid viscosity.  
 

604S/R flow rates

Minimum flows 2 percent of rates given

Tube # 

25

17

122 

82

184

Tube Bore 

4.8mm

6.4mm

9.6mm 

12.7mm

15.9mm

 3/16"

1/4"

3/8" 

1/2"

5/8"

Litre/min 

1.5

2.3

4.2 7.4

11

US gpm 

0.4

0.6

1.1 2.0

2.9

 
604S/R flow rates against suction lift and delivery pressure. Suction lift figures 

obtained with zero delivery pressure. Delivery pressure figures obtained with 

zero suction lift. 
 

Suction (feet of water)

Pressure (bar)

Suction (mmHg)

Pressure (psig)

15.9 

12.7 

6.4 

0

2

4

6

8

10

12

litre

/m

in

15

45

12

16

8

0

30

4

300

400

200

0

1

2

3

100

9.6

Clockwise

Anticlockwise

 

Summary of Contents for 604S/R

Page 1: ...lication PB 0175 Issue 2 IP55 ingress protection variable speed high flow pump Installation and operating instruction Drive s Issue 4 EPROM N A Pumphead s 603R Issue 1 Contents Declarations Page 2 604...

Page 2: ...one pump it complies with Machinery Directive 89 392 EEC and EN60204 1 Low Voltage directive 73 23 EEC and EN61010 1 EMC Directive 89 336 EEC and EN50081 1 50082 1 Responsible person A S Balding Manag...

Page 3: ...nty Watson Marlow Limited warrants subject to the conditions below through either Watson Marlow Limited its subsidiaries or its authorised distributors to repair or replace free of charge including la...

Page 4: ...ng that peristaltic pumps are self priming and will hold their prime up to several metres so there may be no need for non return or foot valves nor for the loading valves required on many other kinds...

Page 5: ...el Alternative connectors are supplied to screw into the entry point gland One accepts 20mm rigid or flexible conduit and the other accepts three core 0 75 square millimetre PVC smooth sheathed mains...

Page 6: ...eed control ratio of the 604S R is 50 1 giving a speed range from approximately 4rpm to its rated maximum speed of 165rpm Flow rates The flow rates given below were obtained using Watson Marlow 3 2mm...

Page 7: ...ly degreased slide the rotor into position The rotor is attached to the drive spindle via a split collet and it is important that the rotor retaining screw is fully tightened a torque of 13Nm to preve...

Page 8: ...ty controlled to our own specifications We recommend Marprene tubing whenever it is chemically suitable The Product Codes for the range of tubing suitable are listed below Tubing for 603R pumphead Bor...

Page 9: ...required Guard switch and magnet Grommet MR 0258M SW 0139 MRA0161A GR 0008 and follower roller Drive spares Direction switch MN 0690S Vertical gasket 4 required MR 0506H Wiring harness MR 0771S Gasket...

Page 10: ...operation If the pump needs cleaning use a cloth dampened with water and mild detergent Do not use strong solvents If harmful liquids are spilled on to the pump first switch off the pump and isolate...

Page 11: ...Page 11 Outline drawing...

Page 12: ...ion 5 4 2 5 2 Serial number 5 4 1 I hereby confirm that the equipment specified has not pumped nor come into contact with any toxic or hazardous substances 5 3 Details of substances pumped Signed 5 3...

Reviews: