background image

pg.10

WATTBOX™ WB-300VB-IP-5 Owners Manual

If connected equipment damage was indicated on your RA request, WattBox will request the make and model of all connected 

equipment, a connection diagram of your system, as well as other requests based on the extent of the request for product placement

 or 

payment for connected equipment damage. All requests by WattBox are to be completed and returned within 30 days. Be sure to note 

its configuration before disconnecting your equipment. 

4. DETERMINATION OF FAILURE:

WattBox will evaluate the protector for surge damage. The protector must show signs of surge damage or must be performing outside 

of design specifications relative to its surge protection capability. Opening the enclosure, tampering with, or modifying the unit in any 

way shall be grounds for an automatic denial of your request for payment. WattBox, after evaluating all information provided, shall, in its 

sole discretion, determine whether or not your request is eligible for payment. 

If the surge protector shows no signs of AC power or signal line surge damage and is working within design specifications, WattBox will 

return the unit to you explaining the test results and notifying you of the rejection of your claim. WattBox reserves the right to inspect 

the damaged connected equipment, parts, or circuit boards. WattBox also reserves the right to inspect the customer’s facility. Damaged 

equipment deemed uneconomical to repair must remain available for inspection by WattBox until the claim is finalized.

5. REQUEST PAYMENTS:

Once WattBox has determined that you are entitled to compensation, WattBox will, at its election, pay you the present fair market 

value of the damaged equipment, or pay for the cost of the repair, or send you replacement equipment, or pay the equivalence of 

replacement equipment.

6. OTHER INSURANCE/WARRANTIES:

This coverage is secondary to any existing manufacturer’s warranty, implied or expressed, or any insurance and/or service contract that 

may cover the loss.

7. EXCLUSIONS:

THE WattBox SURGE PROTECTOR EQUIPMENT POLICY DOES NOT APPLY TO: Service charges, installation costs, reinstallation 

costs; setup cost; diagnostic charges; periodic checkups; routine maintenance; loss of use of the product; costs or expenses arising out 

of reprogramming or loss of programming and/or data; shipping charges or fees; service calls; loss or damage occasioned by fire, theft, 

flood, wind, accident, abuse or misuse; and products subject to manufacturer’s recall or similar event.

8. DISPUTE RESOLUTION:

Any controversy or claim arising out of or relating to WattBox’s Surge Protector Equipment Policy, or the alleged breach thereof, shall 

be settled by arbitration administered by the American Arbitration Association under its Commercial Arbitration Rules. You may file 

for arbitration at any AAA location in the United States upon the payment of the applicable filing fee. The arbitration will be conducted 

before a single arbitrator, and will be limited solely to the dispute or controversy between you and WattBox. The arbitration shall be held 

in any mutually agreed upon location in person, by telephone, or online. 

Any decision rendered in such arbitration proceedings will be final and binding on each of the parties, and judgment may be entered 

thereon in a court of competent jurisdiction. The arbitrator shall not award either party special, exemplary, consequential, punitive, 

incidental or indirect damages, or attorney’s fees. The parties will share the costs of arbitration (including the arbitrator’s fees, if any) in 

the proportion that the final award bears to the amount of the initial claim.

9. GENERAL

If you have any questions regarding the product warranty or the connected equipment protection policy, please contact the WattBox 

Customer Service Department. This warranty supersedes all previous warranties. This is the only warranty provided with the protector 

and any other implied or expressed warranties are nonexistent. This warranty may not be modified except in writing, signed by an 

officer of the SnapAV Corporation.

CONTACTING TECHNICAL SUPPORT

Phone:

 (866) 838-5052 - 

Email:

 Techsupport@snapav.com

Summary of Contents for WB-300VB-IP-5

Page 1: ...ntly disconnect AC Power Noise Filtration Eliminates AC noise to improve picture and sound quality Flexible Power Cords Wattbox power cords are both flexible and durable and designed for ease of installation Flexible Mounting Flat compact design for easy mounting in a VersaBox structured wiring enclosure on a wall or behind a desk or TV IP Control Provides control of outlets over an IP network Tur...

Page 2: ...ration on the next page 3 Reset Press to restart the network card no settings are changed Note The reset button does NOT restore factory defaults this can be done using the Wattbox Utility Software 4 UPS Link For connection to a WattBox IP unit 5 RJ45 Network Connection Connect to the Local Area Network LAN for IP control and monitoring 6 Removable Power Cable Cord is detachable so that the best f...

Page 3: ... via the WattBox interface Green Flashing Firmware for the WattBox processor is being updated During this state the WattBox cannot be accessed via the interface Red Solid WattBox processor is NOT in an operating state Press the reset button Auto Reboot Green Solid Auto Reboot is enabled WattBox power cycle outlets that are ON when communication with assigned website IP addresses are lost Outlets t...

Page 4: ... second screwdriver to disengage the tab and lift that side out of the enclosure 2 Repeat on the other side 3 Use a second screwdriver to help lift the WB 300VB ip 5 out of the cutout SURFACE MOUNTING The WB 300VB IP 5 may be mounted into a cutout or flat on a wall using the included angle brackets 1 For wall mounting locate wall studs using a stud finder not included 2 For installation in a cutou...

Page 5: ...attBox Utility Open the WattBox LAN IP Setup Quick Start Guide PDF and follow the instructions for using the Utility software Web Interface Access After using the WattBox utility you may access the web interface locally to continue IP configuration Visit the product support tab for this WattBox product for web interface documentation Internet 16 15 14 13 12 11 10 9 1 2 3 4 5 6 7 8 abc def ghi jkl ...

Page 6: ... Do not touch any power line or power circuit Doing so may cause severe physical injury or possibly death WARNING Liquid Avoiding Electrical Shocks Do not operate the Component if liquid of any kind is spilled onto or inside the unit Do not operate the Component near rain or water that s spilled or contained e g bathtub kitchen or sink WARNING Power Cord Safety When routing the Component s AC powe...

Page 7: ...one or more components to another Wattbox Too much current may be drawing through one Wattbox Component is not receiving power Component is plugged into a controlled outlet and the outlet is off Log into WattBox interface to turn the outlet On Component is plugged into a controlled outlet but power on the component is not On In some instances a component plugged into a switched outlet won t receiv...

Page 8: ...449 3rd Edition 500V Joule Rating 2160 Joules Surge Component Ceramic Encased MOV Protection Modes L N L G N G Peak Impulse Current 48 000A Disconnect Circuitry Yes Thermal Fuse Yes EMI RFI Noise Filtration All Outlets 53dB 1kHz to 1MHz Operating Temperature Range 14 to 104 F 10 to 40 C UL Certifications UL 60950 1 UL 1449 UL 498 UL 497A B UL 1283 Dimensions 7 9 W x 2 7 H x 6 75 D w o brackets Con...

Page 9: ...e or lightning surge while connected to a properly installed WattBox surge protector WattBox must determine that the surge protector shows signs of surge damage or is operating outside of design specifications relative to its surge protection capability and under all of the circumstances failed to protect your connected equipment THIS POLICY IS SUBJECT TO THE CONDITIONS BELOW 1 PROOF OF PURCHASE R...

Page 10: ...ice contract that may cover the loss 7 EXCLUSIONS THE WattBox SURGE PROTECTOR EQUIPMENT POLICY DOES NOT APPLY TO Service charges installation costs reinstallation costs setup cost diagnostic charges periodic checkups routine maintenance loss of use of the product costs or expenses arising out of reprogramming or loss of programming and or data shipping charges or fees service calls loss or damage ...

Page 11: ...WATTBOX WB 300VB IP 5 Owners Manual pg 11 2020 WattBox ...

Page 12: ...d or other countries 4Store 4Sight Control4 My Home Snap AV Araknis Autonomic BakPak Binary Dragonfly Episode Luma Mockupancy Nearus NEEO OvrC Pakedge Sense Strong SunbriteTV Triad Visualint WattBox and Wirepath are also registered trademarks or trademarks of Wirepath Home Systems LLC Other names and brands may be claimed as the property of their respective owners All specifications subject to cha...

Reviews: