background image

Page 20

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note:  Depending on incoming feed water conditions replacement time frame may vary.

Description

Change time Frame

Price

Sediment Pre-filter: #5m-10

6  Months

$4.50

Carbon Pre-filter:

#GAC-410-56/#5MCB

6  Months

$9.00/10.50

Final Carbon filter

#1m-6/#1M-10

12  Months

$9.00/11.95

R.O. Membrane:

#TFM-24

2 to 5 years

$82.95

This system has been tested according to NSF/ANSI 58 for reduction of the substances below.  The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations
of 0.30 mg/L or less.   This system reduces pentavalent arsenic, but may not remove other forms of arsenic.  This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent
arsenic.  Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic,
Please see the Arsenic Facts section of the Performance Data Sheet for further information.

Avg. In.

Avg. Eff.

% Reduction pH

P r e s s u r e

Max Eff.

Inf. challenge

Max Allowable

concentration

concentration

mg/L

mg/L

Arsenic (Pentavalent) 334.615 ug/L

5.0385 ug/L

98.4%

50psi

19  ug/L

   0.30±10%

   0.010 mg/L

Barium Reduction

10.2 mg/L

0.207 mg/L

97.9%

7.24

50psi

0.3  mg/L

   10.0±10%

    2.0

Cadmium Reduction

0.036 mg/L

0.0005 mg/L

98.6%

7.49

50psi

0.0007

    0.03±10%

    0005

Chromium (Hexavalent) 0.15 mg/L

0.013 mg/L

91.3%

7.24

50psi

0.03

    0.03±10%

    0.1

Chromium (Trivalent)

0.17 mg/L

.01 mg/L

94.1%

7.24

50psi

0.01

    0.03±10%

    0.1

Copper Reduction

3.1 mg/L

0.03 mg/L

99.0%

7.64

50psi

0.04

    3.0±10%

    1.3

Cysts

222,077#/ml

10  #/ml

99.99%

5 8     minimum 50,000/mL

Fluoride Reduction

8.0 mg/L

0.5 mg/L

93.9%

7.49

50psi

0.7

    8.0±10%

    1.5

Lead Reduction

0.15 mg/L

0.002 mg/L

98.6%

7.49

50psi

0.003

    0.15±10%

    0.010

Radium 226/228

25pCi/L

5pCi/L

80.0%

7.24

50psi

5pCi/L

    25pCiL±10%

    5pCiL

Selenium

0.10

0.008

92.0%

50psi

0.011

    0.10±10%

    0.05

TDS

96.8%

7.84

    750±40mg/L

    187

Turbidity

10.2  mg/L

0.26 mg/L

97.5%

0.83

    11±1 NTU

    0.5 NTU

Note:  Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.

Efficiency rating means the percentage of the total water required to operate the system that is treated and available to the user.

REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.

Phone: (623) 931-1977

Fax:  (623) 931-0191

Email:  wpmail@wattsind.com

GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality.  DO NOT use with
water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.  Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.
2. Operating Temperature:

Maximum: 100°F (40.5°C)

Minimum: 40° (4.4°)

3. Operating Water Pressure:

Maximum: 100 psi (7.0kg/cm2)

Minimum: 40 psi (2.8kg/cm2)

4. pH

3 to 11

5. No iron present in incoming feed water supply.
6. Hardness of more than 7 grains per gallon (120 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.

Model No.

Avg.

Avg.

Avg. TDS DPR

I n f l u e n t

Effluent

IN /EFF

RECOVERY

GALLONS

EFFICIENCY

TDS

TDS

REDUCTION

765 mg/l

23mg/l

96.8%

15.5%

9.06gpd

8.35%

Watts Premier Inc.

 1725 W. Williams Drive C-20

Phoenix, AZ 85027 USA

California Certification # 00-1452

Watts Premier Product Data Sheet

   5 SV Deluxe, CRO-TFM-5SV, Ultra 5 and Pur-Tek, Watts 25, Watts RO-4, Watts RO-5, RO-TFM-4SV, RO-TFM-

Summary of Contents for 5 SV DELUXE

Page 1: ...C 20 Phoenix AZ 85027 Phone 800 752 5582 www wattspremier com Fax 623 931 0191 Save manual for future reference MODELS Warning Please read carefully before proceeding with installation Your failure t...

Page 2: ...erse Osmosis System 4 Tools Recommended For Installation 4 Drill a Hole for the Faucet in a Porcelain Sink 5 Punch a Hole for the Faucet in a Stainless Steel Sink 5 Faucet Installation 6 Adapta Valve...

Page 3: ...8 Open End Wrenches Phillips Screw Driver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 1 4 3 8 Drill Bits Contents of Reverse Osmosis System s e r u t a r e p m e T g n i t a r e p O C 8 7...

Page 4: ...rface material is extremely hard and can crack or chip quite easily Use extreme caution when drilling Premier Manufactured Systems accepts no responsibility for consequential damage resulting from the...

Page 5: ...r as shown A slotted washer is used if it is a non air gap faucet Thread the black stem nut back onto the white threaded stem and thighten within of plastic spacer Check the orientation of the faucet...

Page 6: ...EE DRAWING Remove the Faucet Knob by pinching the two locking tabs inward and then pulling upward on the Knob while the tabs are pinched inward Push the coin cell Battery into the Battery Holder behin...

Page 7: ...ttom of the cabinet Step 11 Step 12 Attach adapta valve as illustrated in the three photos above choosing the configuration that fits your plumbing When attaching the adapta valve to straight pipe thr...

Page 8: ...n pipe Insert screw driver into the opening of the drain saddle and align with drilled hole in drain pipe Using Philips screw driver tighten screws evenly and securely on both sides of the drain saddl...

Page 9: ...ten Step 19 Step 21 Blue Tube Connection Position tank in desired location Stand it upright or lay it on its side using the black plastic stand Measure the blue tube from the RO module over to the tan...

Page 10: ...possible making a downward slope from faucet to drain saddle to allowfor proper drainage Step 25 Note Step 26 Step 27 Red Tube Connection Using the white plastic union in the parts bag determine where...

Page 11: ...ilter Installation If the system has a 6 final filter refer to the 6 inch final filter installation If the 6 final filter has already been installed skip this section Remove the 2 blue caps from the 1...

Page 12: ...remove carbon particles from final filter There is an average of 4 gallons of reject water for every 1 gallon of product water produced Step 6 Open the RO faucet and leave it open until water begins t...

Page 13: ...e water inlet connects 6 Month System Maintenance Turn off incoming water supply to the RO at needle valve on adapta valve Step 1 Step 3 Step 4 Step 5 Step 6 Let system sit for 10 15 minutes after tan...

Page 14: ...11 Annual Maintenance Watts Premier sells a filter change kit which includes pre filters orings a final filter connectors and a wrench Call 1 800 752 5582 or buy online at www wattspremier com Perform...

Page 15: ...an containers Clearly mark each container Watts Premier will test the water and call or mail you the results To change the membrane use a 5 8 wrench to remove the Green Tube on the left side of the me...

Page 16: ...of Housing Note Step 10 Follow the Start Up Instructions Check air pressure when tank is empty Check Air Pressure in the Tank Using a digital air gauge check the air pressure in the tank You should a...

Page 17: ...c o l r e p o r p r o f m a r g a i d e e S e b u t n i a r d n i n o i t c i r t s e R m o r f s i r b e d y b d e s u a c s e m i t e m o s e g a k c o l b r a e l C r e h s a w h s i d r o l a s o...

Page 18: ...10005 MEM TFM 25 GPD DRY 5 a 113004 LID BLACK 1 4 FPT UNASSEMBLED 5 b 113007 LID WHITE 1 4 FPT UNASSEMBLED 6 a 113017 HOUSING FILTER 10 BLUE 6 b 113024 HOUSING FILTER 10 WHITE 7 113032 VESSEL MEM HOUS...

Page 19: ...Page 19 California Certification...

Page 20: ...0 1 Copper Reduction 3 1 mg L 0 03 mg L 99 0 7 64 50psi 0 04 3 0 10 1 3 Cysts 222 077 ml 10 ml 99 99 58 minimum 50 000 mL Fluoride Reduction 8 0 mg L 0 5 mg L 93 9 7 49 50psi 0 7 8 0 10 1 5 Lead Reduc...

Page 21: ...e including a 10 polishing filter instead of a 6 Part No 560066 31 95 Kit Premium Filter replacement kit Compatible with all Watts Premier Reverse Osmosis and other water filtration systems These filt...

Page 22: ...ontinuous trouble free operation Part No 107001 64 95 ea Water Pressure Gauge This gauge mounts onto your outside hose connection to accurately show your home s water pressure up to 300 psi A red need...

Page 23: ...t No 107091 CHROME 44 95 Part No 107075 14 95 pk Part No 107092 GOLD 48 95 Shower Falls Deluxe Shower Handle with Built in Filter Curved Ergonomic Shower Handle Filter Handle Extension Replacement fil...

Page 24: ...Page 24...

Page 25: ...ter your information XX XXXXXX Watts Premier Inc is concerned for the saftey of your personal information Watts Premeir collects personal information when you register with Watts Premier This informat...

Page 26: ...State _______________________________________ Zip Code ___________________ Country USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of...

Page 27: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 28: ...inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of un...

Reviews: