background image

Page 7

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Connect tubes to the RO faucet (Figure A)

This RO faucet is equipped with quick connect fittings for easy tube 

installation. 

1.   In the parts bag, locate one 1/4” red tube, one 1/4” blue tube and one 

3/8” black tube.

2.   Connect the STRAIGHT END of the 

1/4”-BLUE

 tube to the corresponding 

fitting at the base of the faucet.  

Make sure the tube is inserted the full 

3/4” into the fitting.  

3.    Connect the STRAIGHT END of the 

1/4”-RED

 tube to the corresponding 

fitting at the base of the faucet.  

Make sure the tube is inserted the full 

3/4” into the fitting.  

4.   Connect the 

3/8” BLACK

 tube to the fitting at the base of the faucet with the 

black ring.  

Make sure the tube is inserted the full 3/4” into the fitting.  

Mount the RO faucet (Figure B)

NOTE:  A 1.25” mounting hole is required for faucet installation.

5.    Make sure the Locking Tabs are “tucked”. Feed the tubes and the  lower 

faucet  assembly  through  the  mounting  hole  in  the  sink. Test  fit  faucet 

placement.  

6.   Make sure the lower faucet assembly is seated properly inside of the rubber 

washer groove

 NOTE:  Arrow on base indicates FRONT of faucet.

6.  Using a Phillips screwdriver, tighten the two screws until snug. Then, tighten 

each screw alternately until faucet is secure.   Do not overtighten!

7.  Inspect  O-rings  on  lower  faucet  assembly.    Lubricate  with  water-soluble 

lubricant if needed.

Assemble Faucet (Figure C)

7.    Align  the  release  button  on  the  back  of  the  upper  faucet  assembly 

approximately 45° left off the back of the lower faucet assembly.

8.    Press the upper faucet assembly firmly on-to the lower faucet assembly 

and twist clockwise until locked into place. Remove battery cover on faucet 
handle, pull battery tab and replace battery cover.

To Remove Upper Assembly:

      Press in the release button and twist upper faucet assembly counter- 

clockwise. 

 

  Do not remove upper faucet assembly until all water has been 

drained from the system and system has been fully depressurized.

L.E.D. FAUCET MONITOR INDICATOR

This faucet is equipped with a filter change indicator. The indicator light will 

flash BLUE while the water is being dispensed. After approximately six months 

or 2000 gallons of filtered water used the light will change to RED, indicating 

that filters should be changed. After filter change you must reset the monitor 

(Follow the Faucet Indicator Battery Replacement procedure on page 8).

DANGER

  This product contains a button cell battery.  If swallowed, 

it could cause severe injury or death in just 2 hours. Seek 

medical attention immediately.

Premier Monitored (Top Mount Twist) Faucet Installation

INSERT

3/8”-BLACK TUBE 

INSERT

1/4”-RED TUBE

INSERT 

1/4”-BLUE TUBE

RUBBER

WASHER

FRONT

RELEASE

BUTTON

BATTERY

TAB

TWIST

UPPER

ASSEMBLY 

45° ONTO 

BASE

LOCKING

TABS

BACK

Figure A

Figure B

Figure C

LOWER

FAUCET

ASSEMBLY

UPPER

FAUCET

ASSEMBLY

LUBRICATE

O-RINGS

FRONT

Summary of Contents for RO-PURE Plus

Page 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Page 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Page 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Page 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Page 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Page 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Page 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Page 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Page 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Page 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Page 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Page 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Page 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Page 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Page 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Page 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Page 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Page 20: ...Page 20 This page intentionally left blank...

Page 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Page 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...

Reviews: