background image

Page 16

 

 

 
 
 
 

 

 

 

 

 
 
 

 
 

 

TROUBLE SHOOTING

Problem   

 Cause    Solution

1. Low/Slow Production  

Low Water Pressure 

 

Assure a minimum of 40 psi incoming water pressure.

 

 

 

 

 

 

 

Premier sells a booster pump if home water pressure is

 

 

 

 

 

 

 

low.  Maker sure water supply is turned on and Adapta 

 

 

     Valve 

is 

all 

the 

way 

open

 

 

 

Crimps in tubing 

 

Check tubing and straighten or replace as necessary.

  

 

Clogged 

pre-fi lters 

 

Replace pre-fi lters.

 

 

 

Fouled membrane 

 

Replace membrane and fl ow restrictor.

2. Milky colored Water   

Air in system 

 

 

Air in the system is a normal occurrence with initial  

 

 

 

 

 

 

 

 

start up of the RO system. This milky look will  

 

 

 

 

 

 

 

 

 

disappear during normal use within 1-2 weeks.  If  

 

 

 

     condition 

reoccurs 

after 

fi lter change, drain tank 1 to 2    

 

 

     times.

3. Water constantly  

 

Low water pressure 

 

See #1 Above

running unit will not
shut off 

 

 

Crimp in supply tube 

 

Check tubing and straighten or repair as necessary

 

 

 

4. Noise / Water from    

Crimp or restriction in    

Check tubing and straighten or repair as necessary. 

faucet vent hole or noise  

drain line 

 

 

Straighten all drain lines. Clear blockage.  Cut off any 

from 

drain   

     Excess 

tubing

 

 

 

Drain tube clogged 

 

Caused from dishwasher or garbage disposal.

 

 

 

 

 

 

 

Disconnect the 3/8” black line at the drain, clean the  

 

 

 

 

 

 

 

 

3/8” black line out with a wire, then reconnect.  Blowing    

 

 

 

 

 

 

 

air through the line will not always remove the clog.

5. Small amount of water in 

System starting up 

 

Normally it takes 6-10 hours to fi ll tank.  Note: low  

storage tank 

 

 

 

 

 

 

incoming water pressure and/or temperature can  

 

 

 

     drastically 

reduce 

production 

rate.

 

 

 

Low water pressure 

 

See #1 above.

 

 

 

To much air in tank 

 

Tank air pressure should be 5 psi when empty of water.

 

 

 

 

 

 

 

If below 5 psi add air or bleed if above 5 psi.

 

 

 

 

 

 

 

Check only when tank is empty of water.  

 

 

     See 

previous 

page.

6. Water leaks from the fi lter / 

Not properly inserted 

 

Re-insert the fi lter / membrane housing.

    membrane housing   

 

 

 

7. Low water fl ow from faucet 

Check air in tank 

 

Use a Digital Air Gauge for best results.  The empty  

 

 

 

 

 

 

 

 

tank pressure should be 5-7 psi. To reset the air pressure

 

 

 

 

 

 

 

in the tank turn off water supply and drain tank by  

 

 

 

 

 

 

 

             opening faucet. When water stops fl owing out of the  

 

 

 

 

 

 

 

 

faucet.  Remove schrader valve cover pump air into  

 

 

 

     tank 

until 

water 

stops 

fl owing from the faucet. Release    

 

 

 

 

 

 

    

the air out of the schrader valve until you reach 5-7 psi.    

 

 

     Replace 

schrader 

valve 

cover. 

Turn 

on 

Water. 

Available From:

®

freshwater

systems

.com

serving you since 1989

CLICK HERE

Summary of Contents for RO-PURE

Page 1: ...for future reference Warning Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure and possible damage to property Manual Edition 08 21 07 P N 199404 Model RO PURE System Tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance ...

Page 2: ...urchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 6 months Model Number __________ Serial Number ___________ ...

Page 3: ...fety of your personal information Watts Premier collects personal information when you register with Watts Premier This information is stored in our data base and we do not rent sell or share personal information with other people or nonaffiliated companies We reserve the right to send you certain types of communications such as direct mail email or by telephone relating to our products or product...

Page 4: ...of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 Carbon filter recommended change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membran...

Page 5: ...Faucet in a Porcelain Sink 7 Punch a Hole for the Faucet in a Stainless Steel Sink 7 Watts Chrome Monitor Non Monitored Faucet Installation 8 Green Tube Connection From RO Module To The Adapta Valve 9 Adapta Valve Installation 9 Reverse Osmosis Module Mounting 9 Drain Saddle Installation 10 Tank Ball Valve Installation 10 How To Use Quick Connect Fittings For Tubing Connections 11 Blue Tube Connec...

Page 6: ...iver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 1 4 3 8 Drill Bits Contents of Reverse Osmosis RO System Operating Temperatures Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 85 psi 7 43 g cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5NTU Note Reverse Osmosis water should not be...

Page 7: ...arp edges with a file Step 1 Step 2 Drill a Hole for the Faucet in a Porcelain Sink Most sinks are predrilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer or soap dispenser you will need an additional hole for the faucet Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Premier accepts no res...

Page 8: ...both the red and green lights will flash to indicate that both lights are functional Thereafter it will flash green only when the faucet handle is turned to the ON position When your system is ready to be serviced approximately six months you will see the light flash red when the handle is turned to the ON position Refer to the Six Month Maintenance page 14 section of this manual for filter replac...

Page 9: ...the RO Module after the Adapta Valve has been installed Remove a brass nut plastic sleeve and brass insert from the parts bag Place nut on the green tube coming from the RO Module first then the plastic sleeve small taper end of plastic sleeve must point to the end of tube and then insert the brass insert into the end of the tube Insert the green tube into the opening on the Adapta Valve supplied ...

Page 10: ...either above the disposal or if a second sink drain is available install it above the cross bar on the second sink Installation of the drain line near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Watts offers drain line installation kits that can be used with garbage disposals part numbers 164014 and 164020 Assemble the drain saddle around...

Page 11: ...burrs and sharp edges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the sy...

Page 12: ...saddle and tighten the black nut securely This is a gravity fed line if there is any dip or kink in the tube the rinse water will not flow into the drain properly Water will back up and come out the air gap hole in the back of the faucet base The tubing must be as SHORT and STRAIGHT as possible making a downward slope from faucet to drain saddle to allow for proper drainage Step 26 Note Note Step ...

Page 13: ...rature and pressure After the tank has filled open the RO An optional ice maker kit not included may be purchased from Watts Premier by calling 1 800 752 5582 or buy on line at www wattspremier com If system is connected to an ice maker turn the ice maker off or do not allow water to flow to the ice maker until Step 3 flushing is complete and the tank has been allowed to completely fill Connection...

Page 14: ...mbranes have a life expectancy of between 2 and 5 years depending on the incoming water conditions and the amount of use of the RO system Normally a membrane would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane A water sample may be...

Page 15: ... 4 Filter Cartridges 2 125089 FITTING ELBOW 90 QC 1 4TX1 4I 3 622036 FLOW RESTRICT 550 STAND ALONE 4 134003 VALVE SHUT OFF 1 4 Q C RES 5 119007 TANK 3 GALLON METAL WHITE 7 134007 ADAPTA VALVE 8 116074 FAUCET AG WATTS CHROME MONITOR 9 134018 VALVE BALL ELB 1 4QCX1 4F The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids ...

Page 16: ...be clogged Caused from dishwasher or garbage disposal Disconnect the 3 8 black line at the drain clean the 3 8 black line out with a wire then reconnect Blowing air through the line will not always remove the clog 5 Small amount of water in System starting up Normally it takes 6 10 hours to fill tank Note low storage tank incoming water pressure and or temperature can drastically reduce production...

Page 17: ...7 24 50psi 4 3 27 0 10 10 0 Nitrite 3 1 0 41 86 0 7 24 50psi 0 46 3 0 10 1 0 Nitrate Nitrite 30 4 2 86 0 7 24 50psi 4 8 30 0 10 10 0 Perchlorate 0 14 0 003 97 0 7 39 50psi 0 005 mg L 0 10 10 0 006 Radium 226 228 25pCi L 5pCi L 80 0 7 24 50psi 5pCi L 25pCiL 10 5pCiL Selenium 94 85 0 2 97 0 7 24 50psi 0 2 0 10 10 0 05 TDS 741 22 97 0 7 28 50psi 26 0 750 40mg L 187 Recovery 15 77 Daily Production Rat...

Page 18: ... from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water system This Watts Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic Under laboratory standard testing conditions this system reduced 0 30 mg L ppm pentavalent arsenic to under 0 010 mg...

Page 19: ...t that turns red to notify you for filter replacement Part No 116000 Chrome Non Monitored 49 95 each 116072 Brushed Nickel Non Monitored 59 95 each 116074 Chrome Monitored 69 95 each Watts Premier Hot Water Recirculation Pump Bring convenience and saving to your home giving you hot water instantly at every faucet when you need it This unique product is easy to install and not only provides you wit...

Page 20: ...pres sure which may exceed readings during the day High pressure readings may indicate the need for pressure regulator to prevent damage to appliances Part No 261003 14 95 each Whole House Filter Great for sediment problems such as in well water supply or areas where dirt and rust particles are a problem Includes three 50 Micron sediment filters and wrench 3 4 ports Part No 500223 86 95 each Repla...

Page 21: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 Part No 107075 14 95 pk All In One reversible High Flow Filter Deluxe 5 Way Massaging Spray Replacement filter Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 47 50 Part No 107080 18...

Page 22: ...ot be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This warranty does ...

Reviews: