ELECTRICAL
SAFETY WARNING
Warning - Risk of electrical shock - This pump is supplied with a grounding conductor. To
reduce the risk of electric shock, be certain that it is connected only to a properly grounded
grounding type receptacle. The safe operation of this pump requires that it be grounded in
accordance with the National Electrical Code and local governing codes and
regulations.
Electrical Requirements
The operating voltage and other electrical data are marked on the motor label. Make sure
that the motor is suitable for the electrical supply on which it will be used.
Electrical Connection
Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet.
TIMER CONTROL TECHNICAL DATA
Supply Voltage: 120 VAC, 60Hz
Temp. Range: –40°F to 180°F
Shortest Switching Interval: 15 minute increment
Switch Modes: “Timer”, “ON” Override, “OFF”Override
Protection: Clear plastic cover for dust and moisture protection of the clock face.
Timer Technical Application
The timer control is designed only for use with the specified
WATTS INSTANT HOT WATER
RECIRCULATING SYSTEM
. Installed indoors on hot water service systems.
The timer control is designed to turn the circulator on and off at preset times, allowing the
user to select operation of the circulator during high use periods of the day.
Page 5
SENSOR VALVE OPERATION
If there is no hot water at the faucet or there appears to be too much hot water on the cold
water side the following steps will determine if the valve is operating correctly:
1. Close the cold water stop valve below the sink.
2. Open the cold water faucet.
3. Water should slowly flow from the faucet until hot water reaches the valve.
The flow should gradually decrease until no water is coming from the faucet
at which time the valve is closed.