USA:

  T: (978) 689-6066 • F: (978) 975-8350 • Watts.com

Canada:  

T: (888) 208-8927 • F: (905) 481-2316 • Watts.ca

Latin America:  

T: (52) 55-4122-0138 • Watts.com

IOM-OFPSYS   2141 

EDP# 88005079 

© 2021 Watts

Conditions

1.   OneFlow

®

+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. 

The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.

2.   The  OneFlow

®

+

 system must be installed in applications with municipally supplied water adhering to EPA guidelines. 

3.  Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation.
4.  Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.
5.  Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.
6.   Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.  

(Please contact your water treatment specialist.)

7.   Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in 

warranty.

8.   Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of 

warranty adjustment is made.

9.   Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value 

and of then current production.

Limitations

Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any 

part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the 

owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.
Our obligation under this warranty with respect to the OneFlow

®

+

 media will be limited to furnishing a replacement for the media within two 

years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding 

freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any 

other operation outside of the limits shown under Specifications, is not covered by this warranty.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY 

WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS 

REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator 

Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost 

profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, 

or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, 

misapplication or improper installation of the product.  
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of 

incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and 

you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights. SO FAR AS IS 

CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE 

WARRANTY PERIODS STATED ABOVE.

Limited Warranty

•   The  OneFlow

®

+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original 

shipment.

•   The  OneFlow

®

+

 cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and 

operated in accordance with the instructions in the corresponding Installation and Operation Manual.

Summary of Contents for 7100638

Page 1: ...heater Do not expose the system to freezing temperatures Water freezing in the system causes equipment damage Do not install in direct sunlight Ultraviolet rays from the sun may cause damage Do not use on water that is microbiologically unsafe or of unknown quality IOM OFPSYS OFPSYS If you are unsure about installing your Watts OneFlow system contact a Watts representative or consult a professiona...

Page 2: ...the system in a place where water damage is least likely to occur if a leak develops 141 2 45 16 11 8 32 Min to 60 A F F Installation Height Side View Using OneFlow System with Other Water Treatment Equipment Due to the unique properties of OneFlow there are some unique requirements for using OneFlow in conjunction with filtration or other forms of water treatment 1 OneFlow must be the last stage ...

Page 3: ... bar to 6 2 bar Temperature 40 F to 100 F 5 C to 38 C Free Chlorine 2 ppm Iron maximum 0 3 ppm Manganese maximum 0 05 ppm Copper maximum 1 3 ppm Oil H2S Must be Removed Prior to OneFlow Total Phosphates 3 0 ppm Silica maximum 20 ppm TDS 1500 mg L NOTICE Systems using OneFlow technology are effective at controlling lime scale formation inside the plumbing system at influent hardness levels up to 30...

Page 4: ...ater Close the supply valve when a steady stream of water comes out of the outlet port If the outlet is flowing into a bucket water could splash on nearby objects If this threatens the safety value structure or appear ance of these objects protect remove them or use the outlet hose to drain option 10 Close the inside faucet 11 Connect the outlet of the OneFlow system to the cold water supply to th...

Page 5: ...e that it is sealed correctly as shown in Diagram C 9 Insert Outlet Connector Item 8 into outlet port and secure back on top of the OneFlow Scale Reduction cartridge as shown in Diagram D 10 Place Head Assembly back onto OneFlow Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in Diagram E DO NOT OVER TIGHTEN 11 Close the pressure relief valve by ti...

Page 6: ... cloth or sponge In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water We recommend the use of modern soaps for the best results Things to watch for During the first 30 90 days Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater You may also see milky water after installation ...

Page 7: ...Flow Carbon Block Cartridge 7100640 OFPSP Scale Prevention Cartridge 7100641 OFPCOM Scale Prevention and Carbon Block Combo Pack ONEFLOW SYSTEM REPLACEMENT PARTS 7300759 OFPHSG Housing and Head Assembly 7300760 OFPAP Inlet Outet Red Adapter Locking Pin 7300761 OFPA 1 In NPT Inlet Outlet Adapter 7300762 OFPOC Outlet Connector 7300763 OFPTOOL Multifunction Tool 7300764 OFPMB System Mounting Bracket ...

Page 8: ... freight and local labor charges if any Damage to the media due to chlorine other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications is not covered by this warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT WATTS REGULATOR COMPANY M...

Page 9: ...ponga el sistema a temperaturas bajo cero La congelación del agua en el sistema causa daños en el equipo No lo instale bajo la luz solar directa Los rayos ultravioletas del sol pueden causar daños No utilizar en agua que sea microbiológicamente insegura o de calidad desconocida IOM OFPSYS OFPSYS Si tiene dudas sobre la instalación de su sistema Watts OneFlow póngase en contacto con un representant...

Page 10: ...al medidor de agua o a los paneles eléctricos Instale el sistema en un lugar donde sea menos probable que se produzcan daños por agua si se produce una fuga 141 2 36 83 cm 45 16 10 95 cm 11 8 2 86 cm De 32 81 3 cm mín a 60 152 4 cm A F F Altura de la instalación Vista lateral Uso del sistema OneFlow con otros equipos de tratamiento de agua Debido a las propiedades únicas de OneFlow existen algunos...

Page 11: ... Manganeso máximo 0 05 ppm Cobre máximo 1 3 ppm Aceite y H2S Deberán eliminarse antes de OneFlow Fosfatos totales 3 0 ppm Sílice máximo 20 ppm TDS 1500 mg L AVISO Los sistemas que utilizan la tecnología OneFlow son efectivos para controlar la formación de sarro y cal dentro del sistema de fontanería a niveles de dureza afluentes de hasta 30 granos por galón 513 ppm como carbonato de calcio Dadas l...

Page 12: ... carcasa se llene de agua Cierre la válvula de suministro cuando salga un flujo constante de agua por el puerto de salida Si la salida fluye hacia una cubeta el agua podría salpi car los objetos cercanos Si esto amenaza la seguridad el valor la estructura o la apariencia de estos objetos protéjalos retírelos o use la manguera de salida para drenar la opción 10 Cierre el grifo interior 11 Conecte l...

Page 13: ...asegurándose de que esté sellado correctamente como se muestra en el diagrama C 9 Inserte el conector de salida elemento 8 en el puerto de salida y asegúrelo nuevamente en la parte superior del cartucho de reducción de sarro OneFlow como se muestra en el diagrama D 10 Vuelva a colocar el conjunto del cabezal en la carcasa OneFlow y con la herramienta multifunción apriételo atornillando el conjunto...

Page 14: ...bones y champús se enjuagarán mucho más fácil y rápido de lo que lo harían con el agua blanda tradicional Recomendamos el uso de jabones modernos para obtener los mejores resultados Detalles para tener en cuenta Durante los primeros 30 a 90 días Los aireadores y desagües del grifo pueden taponarse ocasionalmente a medida que se elimina el sarro viejo incrustado en su sistema de fontanería y calent...

Page 15: ...ial 7100640 OFPSP Cartucho de prevención de sarro 7100641 OFPCOM Paquete combinado de prevención de sarro y bloques de carbono PIEZAS DE REPUESTO DEL SISTEMA ONEFLOW 7300759 OFPHSG Conjunto de carcasa y cabezal 7300760 OFPAP Pasador adaptador de seguridad rojo de entrada salida 7300761 OFPA Adaptador de entrada salida NPT de 1 in de entrada 7300762 OFPOC Conector de salida 7300763 OFPTOOL Herramie...

Page 16: ...uno excluyendo el flete y los cargos de mano de obra local si corresponde Los daños a los medios debidos al cloro otros oxidantes o incrustaciones causadas por las condiciones locales del agua o cualquier otra operación fuera de los límites que se muestran en las especificaciones no están cubiertos por esta garantía LA GARANTÍA ESTABLECIDA EN ESTE DOCUMENTO SE OTORGA EXPRESAMENTE Y ES LA ÚNICA GAR...

Page 17: ...s températures glaciales De l eau qui gèle dans le système peut endommager l équipement N installez pas le système en plein soleil Les rayons ultraviolets du soleil peuvent causer des dommages N utilisez pas le système avec de l eau posant un danger microbiologique ou dont la qualité est inconnue IOM OFPSYS OFPSYS Si vous avez des doutes à propos de l installation de votre système Watts OneFlow ve...

Page 18: ...ù les dégâts d eau sont les moins susceptibles de se produire en cas de fuite 141 2 po 368 3 cm 45 16 po 10 9 cm 11 8 po 2 9 cm 32 po min à 60 po A F F 81 3 cm à 152 4 cm Hauteur d installation Vue de côté Utilisation des systèmes OneFlow avec un autre équipement de traitement de l eau En raison des propriétés uniques de OneFlow il existe des exigences particulières pour l utilisation de OneFlow e...

Page 19: ... 69 bar à 6 2 bars Température 40 F à 100 F 5 C à 38 C Sans chlore 2 ppm Fer maximum 0 3 ppm Manganèse maximum 0 05 ppm Cuivre maximum 1 3 ppm Huile et H2S Doivent être retirés avant OneFlow Phosphates totaux 3 0 ppm Silice maximum 20 ppm MDT 1 500 mg l AVIS Les systèmes utilisant la technologie OneFlow sont efficaces pour contrôler la formation de tartre à l intérieur du système de plomberie à de...

Page 20: ...r d eau Fermez le robinet d alimentation lorsqu un flux d eau régulier s écoule de l orifice de sortie Si la sortie coule dans un seau l eau peut écla bousser les objets à proximité Si cela menace la sécurité la valeur la structure ou l apparence de ces objets protégez les ou retirez les ou utilisez un tuyau de sortie pour l écoulement 10 Fermez le robinet à l intérieur 11 Raccordez la sortie du s...

Page 21: ...ts en s assurant que celle ci est verrouillée correctement comme indiqué dans le schéma C 9 Insérez le raccord de sortie article 8 dans l orifice de sortie et fixez le sur le dessus de la cartouche antitartre OneFlow comme indiqué dans le schéma D 10 Placez la tête sur le boîtier OneFlow et à l aide de l outil polyvalent serrez en vissant la tête dans le sens des aiguilles d une montre comme indiq...

Page 22: ...on et le shampoing se rincent également bien plus facilement et plus rapidement qu avec de l eau douce conventionnelle Nous vous recommandons d utiliser des savons modernes pour obtenir les meilleurs résultats À surveiller Pendant les 30 à 90 premiers jours Les aérateurs et les drains de robinetterie peuvent parfois se boucher lorsque les dépôts de tartre sont enlevés de votre tuyauterie et du cha...

Page 23: ... de charbon et écoulement radial 7100640 OFPSP Cartouche antitartre 7100641 OFPCOM Offre combinée prévention du tartre et bloc de charbon PIÈCES DE RECHANGE DU SYSTÈME ONEFLOW 7300759 OFPHSG Boîtier et tête 7300760 OFPAP Goupille de verrouillage rouge pour adaptateur d entrée de sortie 7300761 OFPA Adaptateur d entrée de sortie NPT 1 po 7300762 OFPOC Raccord de sortie 7300763 OFPTOOL Outil polyval...

Page 24: ...AB à l usine la plus proche sans frais à l exclusion des frais de livraison et de main d œuvre locale le cas échéant Les dommages au média attribuables au chlore à d autres comburants ou à l encrassement provoqué par les conditions locales de l eau ou toute autre opération en dehors des limites indiquées dans les spécifications ne sont pas couverts par la présente garantie LA PRÉSENTE GARANTIE EST...

Reviews: