background image

Servicing and Maintenance 

Before following either or both procedures, close the outlet 

shutoff valve, then close the inlet shutoff valve. Bleed residual 

pressure from the assembly by opening test cocks No. 4, No. 3, 

and No. 2 in this sequence. 
Also, observe the following points. 
• Rinse all parts with clean water before reassembly.
• Do not use any pipe dope, oil, grease, or solvent on any

parts unless instructed to do so.

• Do not force parts. Parts should fit together freely. Excess

force can cause damage and render the assembly

inoperable.

• Carefully inspect seals and seating surfaces for debris or

damage.

• After servicing, repressurize the assembly and test to ensure

proper operation.

• For more information on maintenance, check with your

FEBCO representative or go to FEBCOonline.com.

Check Valve Disassembly 

1. Unscrew the cover and remove the spring and disc holder

assembly. 

CAUTION

! !

Practice safety. The covers are spring loaded. 

2. Inspect the disc and seat area, and clean out any debris.

Replace worn or damaged parts as required. 

3. Apply FDA Approved grease to the cover O-ring and

reassemble the valve in the reverse order of disassembly. 

Relief Valve Disassembly 

1. Detach the activation module, if installed, from the flood

sensor. 

2. Use a #2 Phillips screwdriver to remove the sensor from the

relief valve. 

3. Remove cap screws, diaphragm cover, diaphragm, and

port bushing of the relief valve and then remove the internal 

assembly from the body by pulling it straight out. 

4. Inspect for debris, damage, or fouling of the seat disc. Clean

the parts and replace any as required. 

5. Reassemble in the reverse order of disassembly.
6. Reattach the flood sensor to the relief valve and mount the

activation module to the sensor.

Test Procedure 

Check the ASSE Series 5000 manual for an appropriate test 

method that is consistent with local codes of the area. 

Troubleshooting 

Call customer service if you need assistance with technical details. 

SYMPTOM 

CAUSE 

SOLUTION 

Continuous relief valve discharge 

Debris on check seating surfaces 

Disassemble and clean 

Debris on relief valve seat 

Intermittent relief valve discharge 

Inlet pressure fluctuations 

Eliminate fluctuations 

Downstream pressure surges 

Eliminate surges 

3

 

Summary of Contents for FEBCO 825YA Series

Page 1: ...ust be retested once maintenance has been performed Corrosive water conditions and or unauthorized adjustments or repair could render the product ineffective for the service intended Regular checking...

Page 2: ...ap fitting Before installing the valve into the line flush the supply line of all foreign material Failure to flush the supply line may cause the check valves to become fouled and require disassembly...

Page 3: ...aged parts as required 3 Apply FDA Approved grease to the cover O ring and reassemble the valve in the reverse order of disassembly Relief Valve Disassembly 1 Detach the activation module if installed...

Page 4: ...will at its option replace or recondition the product without charge THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT THE COMP...

Page 5: ...e Un environnement avec des conditions de l eau corrosives et ou des r glages ou des r parations non autoris s peuvent rendre le produit inefficace pour le service pr vu La v rification et le nettoya...

Page 6: ...t d installer la vanne dans la conduite Le d faut de rincer la conduite d alimentation peut provoquer l encrassement des clapets antiretour et exiger un d montage et un nettoyage Apr s l installation...

Page 7: ...s es ou endommag es au besoin 3 Appliquez de la graisse approuv e par le FDA sur le joint torique de couvercle et remontez la vanne dans l ordre inverse du d montage D montage de la soupape de d charg...

Page 8: ...e mat riau et de fabrication dans des conditions normales d utilisation pour une p riode d un an compter de la date d exp dition d origine Si les d fauts susmentionn s venaient se pr senter au cours d...

Page 9: ...te una vez que se haya realizado el mantenimiento Las condiciones corrosivas del agua y o los ajustes o las reparaciones no autorizados podr an hacer que el producto sea ineficaz para el servicio prev...

Page 10: ...istro para eliminar toda materia extra a No enjuagar la l nea de suministro puede provocar que las v lvulas de retenci n se contamine y requiera desarmarse y limpiarse Despu s de la instalaci n llene...

Page 11: ...s residuos Sustituya las piezas desgastadas o da adas seg n sea necesario 3 Aplique grasa aprobada por la FDA a la junta t rica de la cubierta y vuelva a montar la v lvula en el orden inverso al del d...

Page 12: ...do se usen en forma normal durante un periodo de un a o a partir de la fecha de env o original En caso de que tales defectos se presenten dentro del per odo de garant a la Compa a a su criterio reempl...

Reviews: