background image

Page 6

  

 

 

 

  

 

 

 

 

 

 

 

 

 

After drilling, remove all sharp edges and make sure the surroundings 

of the sink are cooled before mounting  the faucet.

Step 3

Step 4

Determine desired  location  for  the RO faucet on your sink and place 

a piece of masking tape over where the hole is  to be drilled.  Mark the 

center of the hole on the tape.

Step 1

Using a variable speed drill set on the slowest speed, drill a 1/8“ pilot 

hole through both porcelain and metal casing of sink at the marked 

center of  the desired location. Use lubricating oil or liquid soap to keep 

the drill bit  cool (If drill bit gets hot it may cause the porcelain to crack 

or chip). 

Using a 1 ¼” diamond tip hole saw, proceed to drill the large hole.  Keep 

drill speed on  the  slowest speed and use lubricating oil or liquid soap 

to keep the hole saw cool during cutting.

Step 2

Counter Top / Porcelain & Stainless Steel Sink

Note:

Most sinks are pre drilled with 1 ¼” diameter hole that you can use for your RO faucet. 

(If you are already using it for a sprayer or soap  dispenser, see step 1)

Porcelain sinks are extremely hard and can crack or chip easily.  

Use extreme caution when drilling.  Watts  accepts no responsibility for 

damage resulting from the installation of faucet. Diamond tip bit recommended.

Marble Counter-top

We recommend contacting a qualified contractor for drilling a hole in a marble counter-top.

Drill a Hole for the Reverse Osmosis Faucet

Summary of Contents for GTS350C

Page 1: ...ng Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Under the counter Reverse Osmosi...

Page 2: ...ecommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appear...

Page 3: ...ect Fittings on Your RO System 7 Mount the Reverse Osmosis Faucet 8 Drain Saddle Installation 8 Red Tube Connection Drain Saddle 8 Green Tube Connection Feed Water 8 Blue Tube Connection RO System 9 T...

Page 4: ...0 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness...

Page 5: ...YELLOW TUBE BALL VALVE CHECK VALVE ELBOW FLOW RESTRICTOR ELBOW WHITE TUBE WHITE TUBE WHITE TUBE BLUE TUBE 1 4 DRAIN SADDLE RO FAUCET Pre Filter sediment FPMB5 978 Housing Lid FH4200WW14 Pre Filter car...

Page 6: ...e porcelain to crack or chip Using a 1 diamond tip hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool durin...

Page 7: ...nect ensure the system is depressurized before removing the tube Push in the col lect squarely against face of fitting With the collet held in this position the tube can be removed The fitting can the...

Page 8: ...you may use a small screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both...

Page 9: ...to the Tee fitting attached to blue and white tubes slip the yellow tube through the white compression nut hand tighten the white nut and add 1 4 turn with a wrench Refer to diagram on page 5 Compres...

Page 10: ...fourth tank can be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming c...

Page 11: ...ith water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re in...

Page 12: ...et and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system at the adapt a valve Keep the RO faucet open...

Page 13: ...embrane when TDS reduction falls below 75 Step 1 Turn off the incoming water supply to the RO at the adapt a valve Open the RO Faucet and allow water to drain from the tank until it is completely empt...

Page 14: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Page 15: ...ssure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tube and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain lines Cle...

Page 16: ...ere is an average of 4 gallons of reject water for every 1 gallon of product water produced REFER TO OWNER S INSTALLATION SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION F...

Page 17: ...valent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If...

Page 18: ...Page 18 Service Record Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2nd stage Carbon 6 months TFM Membrane 2 3 years...

Page 19: ...Page 19...

Page 20: ...nd 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biol...