background image

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

You are required to consult the local building and plumbing 

codes prior to installation.  If the information in this manual 

is not consistent with local building or plumbing codes, 

the local codes should be followed. Inquire with governing 

authorities for additional local requirements.

WARNING

!

Installation, Operation and Maintenance Manual

QT

TM

 Cold Bev Max

TM

 Models: 

QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, 

QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M     

IOM-HS-QTColdBevMax

Table of Contents

System Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Replacement Filters  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Notice to Installers  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Installation Precautions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Filter Cartridge Replacement Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Replacement Parts List   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 
System Drawings   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 
Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

QTCLDBMX-5S-.5M

Tested and certified by WQA against NSF/ANSI 

Standard 42 for the reduction of claims specified on 

the performance data sheet & NSF/ANSI 372 for "lead 

free" compliance .

Do not use with water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after the 

system .

WARNING

!

WARNING

!

Summary of Contents for Hydro-Safe QTCLDBMX-1S-.5M

Page 1: ...ation and Maintenance Manual QTTM Cold Bev MaxTM Models QTCLDBMX 1S 5M QTCLDBMX 2S 5M QTCLDBMX 3S 5M QTCLDBMX 4S 5M QTCLDBMX 5S 5M IOM HS QTColdBevMax Table of Contents System Specifications 2 Replacement Filters 2 Notice to Installers 2 Installation Precautions 2 Operation 2 Installation 3 Maintenance 3 Filter Cartridge Replacement Procedure 3 Replacement Parts List 4 System Drawings 4 Limited Wa...

Page 2: ...g on incoming water quality Notice to Installers Connect the system to cold water supply only Water Temperature cannot exceed 100 F 38 C System must be installed in a vertical upright and level position Do not use with water that is microbiologically unsafe or of unknown water quality Notice to user owner operator Please retain this manual for future reference for parts maintenance or troubleshoot...

Page 3: ...NTO BALL VALVE 7 Install the 8mm tubing into the Quick Connect fitting on the outlet of the system and hold it over a drain Open the 1 4 8mm drain valve 8 Once all inlet and outlet piping has been completed check and make sure all filter housing s are tight slowly open the inlet valve and allow all air to purge from the system through the 1 4 tubing Slowly close the 1 4 8mm drain valve allow the s...

Page 4: ...alve 1 2 NPT Brass HSR BV1 2 Inlet Bottom Mount Pressure Gauge HSR GAUGE Outlet Back Mount Pressure Gauge HHSR GAUGE BKM 20 Prefilter Housing With Gauge Port HSR 20HSPF 12 Prefilter Housing Oring HSR RING S Filter Head 3 8 Top In Out Quick Connect HSR QTHD QC38 Filter Head 3 8 Side In Out FNPT HSR QTHD TT38 Manifold Head First Stage With Oring Inlet HSR QTMHF OR Manifold Head Middle Stage HSR QTMH...

Page 5: ...5 25 70 29 23 5 56 QTCLDBMX 5S 5M Allow 3 76mm of clearance at bottom of system for removal of filter bowls for filter cartridge replacement NOTICE ...

Page 6: ...for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Compa...

Reviews: