background image

2

System Specifications

Maximum Pressure:
All Systems - 100psi (6 .8 bar)
Minimum Pressure:
All Systems - 20psi (1 .4 bar)
Maximum Temperature: 100°F (38°C) 

Minimum Temperature: 40°F (4 .4°C)
Feed Water Quality: pH 6 .5 to 8 .5
Chlorine < 2ppm
Iron (maximum) 0 .3 mg/l
Manganese (maximum) 0 .05 mg/l
Oil & H2S- None allowed
For all other feed water quality requirements abide by the current 

USEPA Safe Drinking Water Act standards .
Inlet/Outlet Connections: 

3

8

" (10mm) NPT for model QTCLDBMX-

1S- .5M . All other systems have 1/2" (15mm) NPT connections 
Maximum Flow Rate: 

System Flow Rate and Capacity

System Model

Flow Rate

Chlorine Capacity

QTCLDBMX-1S-.5M  

1.5 GPM (5.7 LPM)

10,000 Gallons

QTCLDBMX-2S-.5M  

1.5 GPM (5.7 LPM)

10,000 Gallons

QTCLDBMX-3S-.5M

3 GPM (11.4 LPM)  

20,000 Gallons

QTCLDBMX-4S-.5M  

4.5 GPM (17.1 LPM)

30,000 Gallons

QTCLDBMX-5S-.5M  

6 GPM (22.8 LPM)

40,000 Gallons 

The QT Cold Bev Max line is available in different configurations 

depending upon filtration and flow requirements . 

System Replacement Filters

System Model

Filter Ordering Code Frequency

Description

QTCLDBMX-1S-.5M

QTCB15S*

6 Months

15" QT 0.5 Micron Ultra Filtration 

Membrane And Carbon Block 

QTCLDBMX-2S-.5M

HSR-L-SED-5M

6 Months

20" 5 Micron Sediment Pre Filter

QTCB15

6 Months

15" QT 0.5 Micron Ultra Filtration 

Membrane And Carbon Block 

QTCLDBMX-3S-.5M

HSR-L-SED-5M

6 Months

20" 5 Micron Sediment Pre Filter

QTCB15

6 Months

15" QT 0.5 Micron Ultra Filtration 

Membrane And Carbon Block (2)

QTCLDBMX-4S-.5M

HSR-L-SED-5M

6 Months

20" 5 Micron Sediment Pre Filter

QTCB15

6 Months

15" QT 0.5 Micron Ultra Filtration 

Membrane And Carbon Block (3)

QTCLDBMX-5S-.5M

HSR-L-SED-5M

6 Months

20" 5 Micron Sediment Pre Filter

QTCB15

6 Months

15" QT 0.5 Micron Ultra Filtration 

Membrane And Carbon Block (4)

NOTICE

Filter cartridges should be changed at end of filter life, due to lack of 

filtering performance, or whenever a 15 psi pressure drop or greater  

is experienced during normal operation, whichever comes first . 

For all replacement filters and components contact your authorized 

Hydro-Safe Foodservice representative .
*Note: The QTCB15S is the same filter as the QTCB15 . Only the 

label position has been changed so that the label faces forward on 

single cartridge systems .

NOTICE

 

Cartridge capacities are estimates and may be less depending  

on incoming water quality .

Notice to Installers

•  Connect the system to cold water supply only. Water Temperature 

cannot exceed 100°F (38°C) .

•  System must be installed in a vertical, upright and level position. 
•  Do not use with water that is microbiologically unsafe or of  

unknown water quality .

•  Notice to user/owner/operator: Please retain this manual for future 

reference for parts, maintenance, or troubleshooting .

•  It is recommended that all personnel responsible for operation and 

maintenance of this product read the precautions, maintenance, 

and operation sections of this manual .   

Installation Precautions

•  Do not install system on line pressure above the rated pressure as 

noted in System Specifications above .

•  Do not install the system on a hot water line. Failure to limit the 

water temperature to 100°F (38

°

C) can result in housing failure and 

property damage .

•  Do not connect the system backwards with the feed water line 

connected to the outlet . 

•  Do not use liquid pipe thread compounds for threaded  

connections . Use Teflon

®

 tape only .

•  Do not solder plumbing connections that are attached to the  

housings or inlet/outlet fittings . System damage may occur due to 

high temperature .

•  Do not allow the system to freeze. Turn off water supply and drain 

the system if temperature falls below 32°F (0

°

C) . 

•  Do not install system in direct sunlight or where the system will be 

exposed to harsh chemicals or may be subjected to being hit by 

moving equipment, carts, mops, or any other item that may cause 

damage . 

•  Allow 3" (76mm) minimum clearance under the housings for filter 

replacement . 

•  If water hammer is evident, install water hammer arrestors before 

the system . 

•  Do not over tighten fitting connections. 
•  Always back up valves and fittings with a wrench when installing 

fittings to avoid over tightening or loosening existing fittings . 

•  Do not install the unit behind equipment where it may be difficult to 

access the system for future filter replacements . 

Position the system in a suitable location . The direction of flow 

through the system is left to right . Keep this in mind when determin-

ing installation locations . Do not mount the system near any source 

of heat . Also do not mount this system over anything that may be 

adversely affected by water .  

Operation

With sufficient pressure, operation of this system is completely auto-

matic . Dependable operation involves only monitoring system pres-

sure differential, periodic filter changes, and service documentation .   

Replacement Filters

Summary of Contents for Hydro-Safe QTCLDBMX-1S-.5M

Page 1: ...ation and Maintenance Manual QTTM Cold Bev MaxTM Models QTCLDBMX 1S 5M QTCLDBMX 2S 5M QTCLDBMX 3S 5M QTCLDBMX 4S 5M QTCLDBMX 5S 5M IOM HS QTColdBevMax Table of Contents System Specifications 2 Replacement Filters 2 Notice to Installers 2 Installation Precautions 2 Operation 2 Installation 3 Maintenance 3 Filter Cartridge Replacement Procedure 3 Replacement Parts List 4 System Drawings 4 Limited Wa...

Page 2: ...g on incoming water quality Notice to Installers Connect the system to cold water supply only Water Temperature cannot exceed 100 F 38 C System must be installed in a vertical upright and level position Do not use with water that is microbiologically unsafe or of unknown water quality Notice to user owner operator Please retain this manual for future reference for parts maintenance or troubleshoot...

Page 3: ...NTO BALL VALVE 7 Install the 8mm tubing into the Quick Connect fitting on the outlet of the system and hold it over a drain Open the 1 4 8mm drain valve 8 Once all inlet and outlet piping has been completed check and make sure all filter housing s are tight slowly open the inlet valve and allow all air to purge from the system through the 1 4 tubing Slowly close the 1 4 8mm drain valve allow the s...

Page 4: ...alve 1 2 NPT Brass HSR BV1 2 Inlet Bottom Mount Pressure Gauge HSR GAUGE Outlet Back Mount Pressure Gauge HHSR GAUGE BKM 20 Prefilter Housing With Gauge Port HSR 20HSPF 12 Prefilter Housing Oring HSR RING S Filter Head 3 8 Top In Out Quick Connect HSR QTHD QC38 Filter Head 3 8 Side In Out FNPT HSR QTHD TT38 Manifold Head First Stage With Oring Inlet HSR QTMHF OR Manifold Head Middle Stage HSR QTMH...

Page 5: ...5 25 70 29 23 5 56 QTCLDBMX 5S 5M Allow 3 76mm of clearance at bottom of system for removal of filter bowls for filter cartridge replacement NOTICE ...

Page 6: ...for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Compa...

Reviews: