Lync WQ-RS
SECTION 1: INTRODUCTION
L- OMM-005_A
•
2/23/2022
Technical Support • (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
4
of
34
1.1.
Specifications
WQRS-005-R
WQ-RS-010-R
WQ-RS-015-R
Productivity (gallons per day / gallons per
minute)
3600 / 2.5
7200 / 5.0
10800 / 7.5
Quality (typical membrane percent
rejection)
98 %
% Recovery (adjustable)
25 - 75 %
42 - 75 %
50 - 75 %
Membrane Size
4
” x 40”
Number Of Membranes Per Vessel
1
Pressure Vessel Array
1:1
1:1:1:1
1:1:1:1:1:1
Number Of Membranes
2
4
6
Prefilter (system ships with one 5 micron
cartridge)
20" BB
Feed Water Connection
1" NPT
Product Water Connection
3⁄
4
" NPT
Reject Water Connection
3⁄
4
" NPT
Feed Water Required (at 50% recovery)
5 gpm
10 gpm
15 gpm
Feed Water Pressure (minimum)
20 psi
Drain Required (maximum)
15 gpm
Electrical Requirement 230 VAC, 3-ph, 60
Hz (other voltages available)
230 VAC, 3-phase, 60 Hz, 15 amps
(other voltages available)
TEFC Motor (horse power)
5
Dimensions L x W x H (inches)
51” x 18” x 57”
Shipping Weight (estimated pounds)
400
600
800
NOTE:
For all other guideline information, please contact your Lync representative. Published
maximum production rates are based on a feed water of 77°F, SDI of less than 3, 1000 ppm
TDS, and pH 8. Individual membrane productivity may vary (±15%). May be operated on other
feed waters with reduced capacity. Percent rejection is based on membrane
manufacturer’s
specifications; overall system percent rejection may be less.
1.2. RO Overview
Reverse osmosis systems utilize semipermeable membrane elements to separate the feed water
into two streams. The pressurized feed water is separated into purified (product) water and
concentrate (reject) water. The impurities contained in the feed water are carried to drain by the
reject water. It is critical to maintain adequate reject flow in order to prevent membrane scaling
and/or fouling.