Lync WQ-UV
SECTION 1: INTRODUCTION
L- OMM-006_0A
•
1/26/2022
Technical Support • (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
4
of
38
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotopically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Lync UV controller is certified by the Federal Communications Commission (FCC) listed
under identification number
FCC ID: 2AFJT-SMARTSTREAM and Industry Canada (IC) listed under IC: 20623-
SMARTSTREAM.
WARNING!
Lync WQ-UV contains a UV-C emitter (UV lamp). Unintended use of the appliance or
damage to the housing may result in the escape of dangerous UV-C radiation. UV-C
radiation may, even in little doses, cause harm to the eyes and skin. Appliances that are
obviously damaged must not be operated. Do not operate the UV-C emitter when it is
removed from the appliance enclosure. The appliance must be disconnected from the power
supply before replacing the UV-C emitter. DO NOT look directly at the UV-C emitter while it is
ON. Permanent serious eye injury could occur.
WARNING!
This appliance can be used by people aged from 18 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children.
Lync UV systems are engineered with the highest quality components. If at any time a
component needs to be replaced, use only parts recommended and supplied by Lync.
DO NOT add components to or remove components from this system. The UV lamp is rated for
9000 hours under normal operating conditions and should be replaced annually to keep the UV
intensity at the highest possible output. Quartz sleeves should be cleaned as needed or
replaced as needed to guarantee the highest possible UV transmittance into the water. Use only
Lync supplied UV lamps and quartz sleeves. Failure to do so may result in system failure and
will void all warranty.
DO NOT use this system in a manner that it is not intended for. This purifier is only for use in
water applications where the feed water, installation environment and installation method meets
the requirements within this manual. The system must be properly sized.
DO NOT exceed the rated flow rate capacity of the system. Flow controllers are available from
Lync to ensure system's rated flow is not exceeded. Follow all product safety labeling. DO NOT
let the system freeze. System damage may result. Install the system on a flat, and level surface.
The quality of the water to be treated must meet the feed water guidelines within this manual.
Failure to ensure proper pretreatment will result in inadequate disinfection.