background image

Page 3

Cut the tube square. It is 

essential that the outside 

diameter be free of score 

marks, and that burrs and 

sharp edges be removed 

before inserting into 

fi

tting.

Contents of Under  

Counter System

Please make sure all of the items listed below are contained in the 

box. If any of the items are missing please contact retail customer 

service at (888) 321-0500 prior to installing.

•  Filtration System

•  High Capacity Carbon Block 

fi

lter (attached to 

fi

lter head)

•   Brass Insert, Delrin Sleeve, Brass Nut, Blue Tube, QC Union, 

Quick Stem Adapter, Screws

Recommended Tools 

For Installation

•  Small knife or tube cutter

•  Variable speed drill

 •  1/8

"

 (3mm), 1/4

"

 (6.4 mm) and 7/16

"

 (11.0mm) drill bits

 •  Adjustable wrench

•  Phillips screwdriver

Using Quick-Connect Fittings

Cutting

Make certain to push 

the tubing completely 

into the connector until 

it comes into contact 

with the internal tubing 

stop. The collet (gripper) has stainless steel teeth which hold 

the tube 

fi

rmly in position while the O-ring provides a permanent 

leak proof seal.

Pull on the tube to check that it is secure. The system must be 

tested prior to leaving the site and/or before use.

To disconnect, ensure the 

system is depressurized 

before removing the tube. 

Push in collet squarely 

against the face of the 

fi

tting. With the collet held in this position, the tube can be 

removed. The 

fi

tting can then be reused.

Connecting

Disconnecting

System Diagram

Parts List

Item

Description

A

Brass Insert (not shown)

B

Delrin Sleeve (not shown)

C

Brass Nut

D

Blue Tube

E

QC Union

F

Quick Stem Adapter

G

High Capacity Quick Turn Carbon Block Filter (H2O-F45)

HOT

COLD

A

B

C

D

D

E

F

G

Summary of Contents for Pure H2O Series

Page 1: ...n Filter Replacement Design System Tested and certified by WQA against NSF ANSI Standards 42 and 53 for the reduction of the claims specified on the performance data sheet and NSF ANSI Standard 372 for Lead Free Compliance WARNING Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Keep...

Page 2: ...le of Contents Overview 2 System Maintenance 2 Operational Parameters 2 Contents of Under Counter System 3 Recommended Tools For Installation 3 Using Quick Connect Fittings 3 System Diagram 3 Tubing Connections and Mounting 4 Start up Instructions 5 Product Registration 5 Changing the Filter Cartridges 5 Performance Data Sheet 6 Service Record 7 Limited Warranty 8 WARNING Do not use with water tha...

Page 3: ...ewdriver Using Quick Connect Fittings Cutting Make certain to push the tubing completely into the connector until it comes into contact with the internal tubing stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that it is secure The system must be tested prior to leaving the site ...

Page 4: ...nd replacement Mark the location for the mounting screws on the cabinet wall under the sink In the parts bag locate the two self tapping screws Using an electric drill with a Phillips bit screw them into the cabinet at the marked location Hang the system on the screws using the mounting holes in the bracket Step 1 The tubing is now connected on one end to the faucet supply and the other end to the...

Page 5: ...ter from the head by turning to the left then pulling downwards Discard the old filter Step 4 Remove plastic wrapping and cap from new filter Step 5 To install new filter cartridge with the filter label facing approximately 45 degrees to the left push the filter into the filter head and twist it to the right until the filter locks in and the label on filter is facing the front Step 6 Follow start ...

Page 6: ...e with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system While testing was performed under standard laboratory conditions actual performance may vary Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts 2 Operating Temperature Maximum 100o F 38o C Minimum 40o F 4 4o C 3 Operatin...

Page 7: ...e Record Date of Purchase _______________ Model Number _______________ Serial Number _______________ Date of Install _________________ Installed by __________________ High Capacity Quick Turn Carbon filter 12 Months ...

Page 8: ...ioned equipment Parts used in repairing or replacing the system will be warranted for 90 days from the date the system is returned to you or for the remainder of the system s original warranty period whichever is longer This warranty is not assignable or transferable Limitations and Exclusions THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS WITH RESPECT TO ...