III. Operation

A. Installation

  1.   The water supply should be sufficient to provide a minimum of 

20 psig pressure at the design feed flow.

  2.   Proper pretreatment must be determined and installed prior to 

the RO system.

  3.   A fused high voltage disconnect switch located within 10 feet of 

the unit is recommended. This disconnect is not provided with 

the RO system.

  4.   Responsibility for meeting local electrical and plumbing codes 

lies with the owner /operator.

  5.   Install indoors in an area protected from freezing. Space al-

lowances for the removal of the membranes from the pressure 

vessels should be provided. This system requires 42" minimum 

clear space on each side.

B. Plumbing Connections

  1.   Connect the pretreated feed water line to the inlet side of the 

prefilter housing. (Figure # 1 item # 1) A feed water shutoff valve 

should be located within 10 feet of the system.

  2.   Temporarily connect the outlet of the product water flow meter 

to drain. (Figure # 1 item # 2) The product water line should 

never be restricted. Membrane and/or system damage may oc-

cur if the product line is blocked.

  3.   Connect the outlet of the reject water flow meter to a drain. (Fig-

ure # 1 item # 3) The reject drain line should never be restricted. 

Membrane and/or system damage may occur if the reject drain 

line is blocked. An air gap must be located between the end 

of the drain line and the drain. The use of a standpipe or other 

open drain satisfies most state and local codes and allows for 

visual inspection and sampling.

C. Electrical Connections

  1.   A safety switch or fused disconnect should be installed within 10 

feet of the system.

  2.   Verify that the disconnect switch is de-energized using a  

voltmeter.

  3.   Connect the outlet of the disconnect switch to the terminals on 

top of the motor starter (Figure # 2). Attach the power supply 

ground to the chassis ground. It may be necessary to drill a hole 

in the enclosure and install a water tight strain relief or conduit 

connector. The hole size and location must be determined by 

the installer. Check the pump motor nameplate for the amper-

age draw at various voltages to determine the wire size required.

  4.   Do not apply power to the RO unit at this time.

D. Startup

  1.   Verify that the pretreatment equipment is installed and working 

properly. Verify that no free chlorine is present in the feed water.

  2.   Verify that the pump discharge valve (Figure # 1 item D) is open.
  3.   Install a 20" five micron filter cartridge in the prefilter housing. 

(Figure #1 item K)

  4.   Open the reject control valve completely (Figure # 1 item B) by 

turning it counterclockwise. Close the reject recycle control valve 

completely (Figure # 1 item C) by turning it clockwise.

  5.   Open the feed water shutoff valve installed in step III-B-1 above.
  6.   Manually open the inlet solenoid valve (figure #1 item L) by  

turning the white lever located near the valve outlet.

  7.   Water will flow through the system and to drain through the 

reject flow meter (figure # 1 item H).

  8.   Manually close the inlet solenoid valve after the air has been 

purged from the system, or after 10 minutes, whichever  

occurs first.

  9.   Close the pump discharge valve half way. (Figure # 1 item D)
10.    Engage the safety switch or disconnect (installed in step III-C-1 

above) to apply electrical power to the RO system.

11.    Press the on/off button on the controller.  When the pump starts, 

press and hold the on/off  button to turn off the pump and  look 

at the motor fan as the pump stops to determine if the pump ro-

tation is correct. See the controller section for more details. The 

fan should rotate in the direction of the rotation arrow located 

on the pump. Continue with the startup if the pump is rotating in 

the proper direction. If the pump is rotating backwards, change 

the rotation by disconnecting the power and reversing any two 

of the wires on the power inlet. Verify proper pump rotation  

before continuing.

12. Turn the system on.
13.    Adjust the reject control valve(s) (figure # 1 items B & C) and 

the pump discharge valve (Figure # 1 item D) until the desired 

flows are achieved. Closing the reject valve increases the 

product flow and decreases the reject flow. Opening the pump 

discharge valve increases both the reject flow and the product 

flow. See the flow rate guidelines and temperature correction 

table in the appendix to determine the flow rates for different 

operating temperatures.

14.    Allow the product water to flow to drain for 30 minutes.
15.    Turn off the system and connect the product line to the point of 

use. (Figure # 1 item # I) The product water line should never be 

restricted. Membrane and/or system damage may occur if the 

product line is blocked.

16.    Restart the system and record the initial operating data using the 

log sheet in the next section.

See the controller section of this manual for more installation 
and operation information.

NOTICE

It is the responsibility of the end user to ensure that the 
installation is done according to local codes and regulations.

NOTICE

It is the responsibility of the end user to ensure that the 
installation is done according to local codes and regulations.

NOTICE

Summary of Contents for Pure Water PWR4021 Series

Page 1: ...ial Reverse Osmosis Systems Series PWR4021 IOM WQ PWR4021 WARNING Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may...

Page 2: ...evention of fouling or scaling of the membranes is not only a mat ter of system design but also a matter of proper operation Record keeping and data normalization are required in order to know the act...

Page 3: ...day gallons per minute Maximum production based on standard membranes and feed water of 25 C SDI 3 1000 ppm TDS and pH 8 Individual membrane productivity may vary 15 3600 2 5 5400 3 75 7200 5 0 9000...

Page 4: ...pplies will damage the thin film composite structure of the membranes used in this unit Carbon filtration or sodium bisulfite injection should be used to completely remove the free chlorine residual C...

Page 5: ...sure Gauge Indicates the pump dis charge pressure G Reject Pressure Gauge Indicates the reject pressure H Reject Flow Meter Indicates the reject flow rate in gallons per minute gpm I Product Flow Mete...

Page 6: ...6 Figure 2 B Controller Drawing...

Page 7: ...7 B Controller Drawing continued Figure 3...

Page 8: ...e in the prefilter housing Figure 1 item K 4 Open the reject control valve completely Figure 1 item B by turning it counterclockwise Close the reject recycle control valve completely Figure 1 item C b...

Page 9: ...r Retighten to 25 in lbs when vent port runs a steady stream of water Vented Priming Plug Drain Plug It is very important to vent the mechanical seal during startup Failure to vent the seal may result...

Page 10: ...AC 1 amp Motor Contactor Coil 24 VAC 1 amp Circuit Protection Main Power Fuse F1 5 x 20 mm 2 Amp Relay XFMR Fuse F2 5 x 20 mm 0 125 Amp Other Dimensions 11 5 tall 9 3 wide 6 7 deep Nema 4X non metalli...

Page 11: ...24V3 Schematic Rev NC Dec 2015 POWER INPUT PUMP Contactor FLUSH VALVE INLET VALVE DIVERT ALARM Divert Valve Alarm contacts can be powered or dry contact selectable with switch S1 Close on Fault Alter...

Page 12: ...verview Keypad System On Off Up Arrow Down Arrow Manual Run Manual Flush Display 4 line 20 character Provides feedback on the system status CPU Board Conductivity Probe Connections Programing Port Ter...

Page 13: ...13 Figure 6 Wiring Diagram Pictorial Schematic of a Typical ROC 4 System...

Page 14: ...d updates of CPU 4 firmware Main interface port Connects via ribbon cable to Terminal Board Detailed View Optional Feed Conductivity Probe Permeate Conductivity Probe Programming Port Standard USB pri...

Page 15: ...15 Figure 8 Controller Detail Terminal Board TB 3 See Fig 3 for schematic TB24V3...

Page 16: ...Tee or equivalent location Orient the probe so that air cannot become trapped in the area near the probe Conductivity Probe Flow Flow Input wiring for new jumper less transformer Line 2 input for 460...

Page 17: ...ls on the CPU Board See Figure 6 Repeat Steps 6 7 for the Feed Conductivity cell if your system will utilize both feed and permeate conductivity measurement 6 Provide power to the RO system 7 Press th...

Page 18: ...ramming Accessing the hidden menus 1 With the System ON Press and Hold the UP and DOWN Arrows 2 With the UP and Down Arrows depressed press the System On Off Switch The menu will switch to the RO Pres...

Page 19: ...delay Seconds 5 5 1 1 Pump start retry interval restart delay after LP fault Seconds 60 60 60 60 Low pressure fault shutdown of faults Faults 5 5 5 5 Low pressure fault shutdown time period to count f...

Page 20: ...20 Figure 11 Controller Programming Menu Navigation...

Page 21: ...ts 5 Low pressure fault shutdown time period to count faults Minutes 10 Low pressure fault shutdown reset after shutdown 0 value no restart Minutes 60 These three values work together to determine how...

Page 22: ...Fault Permeate conductivity is higher than the alarm set point Line 1 Service Fault Line 2 Permeate TDS xxx ppm or Permeate Cond xxx uS Line 3 Alarm SP xxx ppm or Alarm SP xxx uS Line 4 To Reset Push...

Page 23: ...ing Programming Interface Overview The Programming interface is a Windows based tool for making changes to the ROC software This screen shows the RO settings available There are 4 field selectable set...

Page 24: ...x B Controller Programming Programming Interface Overview The WQ screen allows the configuration of the conductivity probes The status screen shows the input and output status and other operational in...

Page 25: ...UCT TDS PPM FEED WATER TEMP FEED WATER HARDNESS FEED WATER CHLORINE LEVEL PRE FILTER INLET PRESSURE PRE FILTER OUTLET PRESSURE REMARKS Note Change the prefilter when the differential pressure increase...

Page 26: ...pes and vessels Shock dosage of sodium bisulfite Continuous feed of low conc Of bisulfite at reduced pH Formaldehyde sterilization Clean with alkaline anionic surfactant Chlorine dosage up stream with...

Page 27: ...e drop Use higher voltage on transformer terminals or reduce load Check connections Check conductors for proper size Broken rotor bars or loose rotor Look for cracks near the rings A new rotor may be...

Page 28: ...earing Check alignment side and end thrust Broken ball or rough races Replace bearing first clean housing thoroughly These instructions do not cover all details or variations in equipment nor provide...

Page 29: ...Membrane Replacement 1 Turn off the system and close the feed water shutoff valve 2 Disconnect the membrane feed hoses by loosing the brass fittings between the end of the hoses and the pressure vess...

Page 30: ...llowing tables are intended as a guide to determining the flow rates for the PWR4021 series RO systems All flows are in gallons per minute GPM Nominal flows for systems with reject recycle and a feed...

Page 31: ...31 Notes...

Page 32: ...y remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED...