13
General Operation
User (U) Displays/Settings
When the system is operating one of two displays is shown. Pressing
NEXT alternates between the displays. One of the displays is always
the current time of day. The second display is one of the following:
days remaining or gallons remaining. Days remaining are the number
of days left before the system goes through a regeneration cycle.
Capacity remaining is the number of gallons that to be treated before
the system goes through a regeneration cycle. The user can scroll
between the displays as desired.
If the system has called for a regeneration that occurs at the preset
time of regeneration, the words REGEN TODAY are displayed.
When water is being treated (that is, water is flowing through the
system), the word SOFTENING flashes on the display.
If brine tank does not contain salt, fill with salt and wait at least
2 hours before regenerating.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage.
An example of a time with low water usage is when a household is
asleep.
If there is a demand for water when the system is regenerating,
untreated water is used.
When the system begins to regenerate, the display changes to
include information about the step of the regeneration process and
the time remaining for that step to be completed. The system runs
through the steps automatically and resets itself to provide treated
water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage because
of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration
time, when the regeneration time option is set to NORMAL or
ON 0, press and release REGEN. The words REGEN
TODAY flash on the display to indicate that the system is set to
regenerate at the preset delayed regeneration time. If you pressed
REGEN in error, pressing the button again cancels the request.
(Note: If the regeneration time option is set to ON 0, there is no set
delayed regeneration time, so REGEN TODAY does not activate if
REGEN is pressed.)
To initiate a manual regeneration immediately, press and hold REGEN
for 3 seconds. The system begins to regenerate immediately. The
request cannot be canceled.
General Operation
User (U) Displays/Settings
When the system is operating one of two displays will be
shown. Pressing NEXT will alternate between the displays.
One of the displays is always the current time of day. The
second display is one of the following: days remaining or
gallons remaining. Days remaining are the number of days
left before the system goes through a regeneration cycle.
Capacity remaining is the number of gallons that will be treat-
ed before the system goes through a regeneration cycle. The
user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at
the preset time of regeneration, the words REGEN TODAY
will appear on the display.
When water is being treated (i.e. water is flowing through the
system) the word “Softening” flashes on the display.
REGENERATION MODE
Typically a system is set to regener-
ate at a time of low water usage. An
example of a time with low water
usage is when a household is asleep.
If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change
to include information about the step of the regeneration process
and the time remaining for that step to be completed. The system
runs through the steps automatically and will reset itself to pro-
vide treated water when the regeneration has been completed.
MANUAL
REGENERATION
Sometimes there is a
need to regenerate
the system, sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regener-
ation time, when the regeneration time option is set to “NORMAL”
or “ on 0”, press and release “REGEN”. The words
“REGEN TODAY” will flash on the display to indicate that the sys-
tem will regenerate at the preset delayed regeneration time. If
you pressed the “REGEN” button in error, pressing the button
again will cancel the request. Note: If the regeneration time
option is set to “on 0” there is no set delayed regeneration time
so “REGEN TODAY” will not activate if “REGEN” button is
pressed.
To initiate a manual regeneration immediately, press and hold the
“REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
11
CONTROL PROGRAMMING
INSTALLER (
I
) Displays/Settings
STEP 1
I
– Press NEXT and arrow up simulta-
neously for 3 seconds.
STEP 2
I
– Hardness: Set the amount of hard-
ness in grains of hardness as calcium carbonate
per gallon using, arrow down or arrow up but-
tons. The default is 20 with value ranges from 1
to 150 in 1 grain increments. Note the grains per
gallon can be increased if soluble iron needs to
be reduced. Press NEXT to go to step 3I. Press
REGEN to exit Installer Displays/Settings.
STEP 3
I
– Day Override: When gallon capacity
is set to off, sets the number of days between
regeneration’s. When gallon capacity is set to
AUTO or to a number sets the maximum number
of days between regeneration. If value set to “off”
regeneration initiation is based solely on gallons
used. If value is set as a number (allowable
range from 1 to 28) a regeneration initiation
will be called for on that day even if sufficient
number of gallons were not used to call for
a regeneration. Set Day Override using arrow
buttons: number to days between regeneration
(1 to 28); or OFF.
Press NEXT to go to step 4
I
. Press REGEN to
return to previous step.
STEP 4
I
– Next Regeneration Time (hour): Set
the hour of day for regeneration using down or up
arrow buttons. AM/PM toggles after 12. The
default time is 2:00 am. This display shows
“REGEN on 0 GAL” if “on 0” is selected in Step
9S or Step 7F. Press NEXT to go to step 5
I
.
Press REGEN to return to previous step.
STEP 5
I
– Next Regeneration Time (minutes):
Set the minutes of day regeneration using down
or up arrow buttons. This display not be shown if
“on 0” is selected in Step 9S or Step 7F. Press
NEXT to exit Installer Displays/ Settings. Press
REGEN to return to previous step.
To initiate a manual regeneration immediately,
press and hold the “REGEN” button for three
seconds. The system will beam to regenerate
immediately. The control valve may be stepped
through the various regeneration cycles by
pressing the “REGEN” button.
Note: If brine tank does not contain salt, fill with salt
and wait at least two hours before regenerating.
General Operation
User (U) Displays/Settings
When the system is operating one of two displays will be
shown. Pressing NEXT will alternate between the displays.
One of the displays is always the current time of day. The
second display is one of the following: days remaining or
gallons remaining. Days remaining are the number of days
left before the system goes through a regeneration cycle.
Capacity remaining is the number of gallons that will be treat-
ed before the system goes through a regeneration cycle. The
user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at
the preset time of regeneration, the words REGEN TODAY
will appear on the display.
When water is being treated (i.e. water is flowing through the
system) the word “Softening” flashes on the display.
REGENERATION MODE
Typically a system is set to regener-
ate at a time of low water usage. An
example of a time with low water
usage is when a household is asleep.
If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change
to include information about the step of the regeneration process
and the time remaining for that step to be completed. The system
runs through the steps automatically and will reset itself to pro-
vide treated water when the regeneration has been completed.
MANUAL
REGENERATION
Sometimes there is a
need to regenerate
the system, sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regener-
ation time, when the regeneration time option is set to “NORMAL”
or “ on 0”, press and release “REGEN”. The words
“REGEN TODAY” will flash on the display to indicate that the sys-
tem will regenerate at the preset delayed regeneration time. If
you pressed the “REGEN” button in error, pressing the button
again will cancel the request. Note: If the regeneration time
option is set to “on 0” there is no set delayed regeneration time
so “REGEN TODAY” will not activate if “REGEN” button is
pressed.
To initiate a manual regeneration immediately, press and hold the
“REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
11
CONTROL PROGRAMMING
INSTALLER (
I
) Displays/Settings
STEP 1
I
– Press NEXT and arrow up simulta-
neously for 3 seconds.
STEP 2
I
– Hardness: Set the amount of hard-
ness in grains of hardness as calcium carbonate
per gallon using, arrow down or arrow up but-
tons. The default is 20 with value ranges from 1
to 150 in 1 grain increments. Note the grains per
gallon can be increased if soluble iron needs to
be reduced. Press NEXT to go to step 3I. Press
REGEN to exit Installer Displays/Settings.
STEP 3
I
– Day Override: When gallon capacity
is set to off, sets the number of days between
regeneration’s. When gallon capacity is set to
AUTO or to a number sets the maximum number
of days between regeneration. If value set to “off”
regeneration initiation is based solely on gallons
used. If value is set as a number (allowable
range from 1 to 28) a regeneration initiation
will be called for on that day even if sufficient
number of gallons were not used to call for
a regeneration. Set Day Override using arrow
buttons: number to days between regeneration
(1 to 28); or OFF.
Press NEXT to go to step 4
I
. Press REGEN to
return to previous step.
STEP 4
I
– Next Regeneration Time (hour): Set
the hour of day for regeneration using down or up
arrow buttons. AM/PM toggles after 12. The
default time is 2:00 am. This display shows
“REGEN on 0 GAL” if “on 0” is selected in Step
9S or Step 7F. Press NEXT to go to step 5
I
.
Press REGEN to return to previous step.
STEP 5
I
– Next Regeneration Time (minutes):
Set the minutes of day regeneration using down
or up arrow buttons. This display not be shown if
“on 0” is selected in Step 9S or Step 7F. Press
NEXT to exit Installer Displays/ Settings. Press
REGEN to return to previous step.
To initiate a manual regeneration immediately,
press and hold the “REGEN” button for three
seconds. The system will beam to regenerate
immediately. The control valve may be stepped
through the various regeneration cycles by
pressing the “REGEN” button.
Note: If brine tank does not contain salt, fill with salt
and wait at least two hours before regenerating.
General Operation
User (U) Displays/Settings
When the system is operating one of two displays will be
shown. Pressing NEXT will alternate between the displays.
One of the displays is always the current time of day. The
second display is one of the following: days remaining or
gallons remaining. Days remaining are the number of days
left before the system goes through a regeneration cycle.
Capacity remaining is the number of gallons that will be treat-
ed before the system goes through a regeneration cycle. The
user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at
the preset time of regeneration, the words REGEN TODAY
will appear on the display.
When water is being treated (i.e. water is flowing through the
system) the word “Softening” flashes on the display.
REGENERATION MODE
Typically a system is set to regener-
ate at a time of low water usage. An
example of a time with low water
usage is when a household is asleep.
If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change
to include information about the step of the regeneration process
and the time remaining for that step to be completed. The system
runs through the steps automatically and will reset itself to pro-
vide treated water when the regeneration has been completed.
MANUAL
REGENERATION
Sometimes there is a
need to regenerate
the system, sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regener-
ation time, when the regeneration time option is set to “NORMAL”
or “ on 0”, press and release “REGEN”. The words
“REGEN TODAY” will flash on the display to indicate that the sys-
tem will regenerate at the preset delayed regeneration time. If
you pressed the “REGEN” button in error, pressing the button
again will cancel the request. Note: If the regeneration time
option is set to “on 0” there is no set delayed regeneration time
so “REGEN TODAY” will not activate if “REGEN” button is
pressed.
To initiate a manual regeneration immediately, press and hold the
“REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
11
CONTROL PROGRAMMING
INSTALLER (
I
) Displays/Settings
STEP 1
I
– Press NEXT and arrow up simulta-
neously for 3 seconds.
STEP 2
I
– Hardness: Set the amount of hard-
ness in grains of hardness as calcium carbonate
per gallon using, arrow down or arrow up but-
tons. The default is 20 with value ranges from 1
to 150 in 1 grain increments. Note the grains per
gallon can be increased if soluble iron needs to
be reduced. Press NEXT to go to step 3I. Press
REGEN to exit Installer Displays/Settings.
STEP 3
I
– Day Override: When gallon capacity
is set to off, sets the number of days between
regeneration’s. When gallon capacity is set to
AUTO or to a number sets the maximum number
of days between regeneration. If value set to “off”
regeneration initiation is based solely on gallons
used. If value is set as a number (allowable
range from 1 to 28) a regeneration initiation
will be called for on that day even if sufficient
number of gallons were not used to call for
a regeneration. Set Day Override using arrow
buttons: number to days between regeneration
(1 to 28); or OFF.
Press NEXT to go to step 4
I
. Press REGEN to
return to previous step.
STEP 4
I
– Next Regeneration Time (hour): Set
the hour of day for regeneration using down or up
arrow buttons. AM/PM toggles after 12. The
default time is 2:00 am. This display shows
“REGEN on 0 GAL” if “on 0” is selected in Step
9S or Step 7F. Press NEXT to go to step 5
I
.
Press REGEN to return to previous step.
STEP 5
I
– Next Regeneration Time (minutes):
Set the minutes of day regeneration using down
or up arrow buttons. This display not be shown if
“on 0” is selected in Step 9S or Step 7F. Press
NEXT to exit Installer Displays/ Settings. Press
REGEN to return to previous step.
To initiate a manual regeneration immediately,
press and hold the “REGEN” button for three
seconds. The system will beam to regenerate
immediately. The control valve may be stepped
through the various regeneration cycles by
pressing the “REGEN” button.
Note: If brine tank does not contain salt, fill with salt
and wait at least two hours before regenerating.