7
Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100116
Includes:
• (1) Sediment Filter
• (1) Carbon Block Filter
Note: Your UF Drinking Water Module is equipped with valved
heads which will automatically turn off the water supply to each
filter when the filter is released, thus you do not need to turn off
the incoming water supply at the Adapt-A-Valve™. The faucet
must be off when filters are replaced.
Step A –
Place the towel under the UF Drinking Water Module to
catch any excess water that drips out from the filters during
the changeover .
Step B –
To make the removal of the
filter housings easier, the heads
& housings may be lifted up
to 90 degrees as shown in the
pictures to the right . Starting
with the sediment filter, lift the
cartridge up to 90 degrees .
Rotate the cartridge a
1
⁄
4
turn
counterclockwise, remove and
dispose of used cartridge .
Step C –
Make sure to remove the
cap off of the new replace-
ment filter . Insert the new filter
cartridge into the head and
rotate it clockwise
1
⁄
4
turn until
it stops . Return cartridge to the
vertical position .
Step D –
Repeat this procedure for the
2nd filter cartridges . When
finished, flush your tank com-
pletely once to remove any nat-
ural carbon fines from the UF
Drinking system . Check over
the next 24 hours to ensure no
leaks are present .
Photographs for reference purposes
only for Kwik-Change™ drinking water
systems . Your system may contain 2, 3,
or 4 filter cartridges .
6-Month System Maintenance
Annual Maintenance
Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100118
Includes:
• (1) Sediment Filter
• (1) UF Membrane
• (1) Carbon Block Filter
Note: Your UF Drinking Water module is equipped with valved
heads which will automatically turn off the water supply to each
filter when the filter is released, thus you do not need to turn off
the incoming water supply at the Adapt-A-Valve™. The faucet
must be off when filters are replaced.
Step A –
Place the towel under the UF Drinking water module to
catch any excess water that drips out from the filters during
the changeover .
Step B –
To make the removal of the
filter housings easier, the heads
& housings may be lifted up
to 90 degrees as shown in the
pictures to the right . Starting
with the sediment filter, lift the
cartridge up to 90 degrees .
Rotate the cartridge a
1
⁄
4
turn counterclockwise, remove
and dispose of used cartridge .
Step C –
Make sure to remove the
cap off of the new replace-
ment filter . Insert the new filter
cartridge into the head and
rotate it clockwise
1
⁄
4
turn until
it stops . Return cartridge to the
vertical position .
Step D –
Repeat this procedure for the
2nd and 3rd filter cartridges .
When finished, flush your tank
completely once to remove
any natural carbon fines from
the UF Drinking Water system .
Check over the next 24 hours
to ensure no leaks are present .
Photographs for reference purposes only for Kwik-Change™ drinking