Troubleshooting

This section provides troubleshooting solutions to the most common issues if your Cellular 

Gateway is not working correctly . If you are unable to resolve your issue, contact your local 

Watts representative to order a replacement device .

Poor or No Cellular Reception

Poor or no cellular reception will cause notifications to not work . As noted in the Installation, 

Operation and Maintenance Manual, the installation location is important for cellular reception . 

If the CELLULAR LED is OFF or blinking, the most likely issue is poor reception . If the device is 

still not working, review the possible causes and solutions below .

Possible Cause 1

The location where the antenna is installed may be interfering with cellular reception .

Note:

 Care should be taken to ensure that the antenna side of the device is installed away 

from any walls, wires, pipes, or other obstructions, particularly anything metallic .

Solution 1

Move the Cellular Gateway to a location where the antenna is not facing any internal walls, 

wires, pipes, or other obstructions, such as an electrical box .

Possible Cause 2

The location has poor cellular reception .

Solution 2

Move your Cellular Gateway to a different location and check to see that the CELLULAR LED 

is solid blue; if it is not, move the device until you find a location with better cellular reception .

Note:

 You can install the Cellular Gateway up to 100 feet away from the Junction Box . Six 

feet of wire is supplied with the Cellular Gateway . If additional wire is used, it must meet the 

required rating for the Junction Box (300V, 16-24 AWG) .
Please consider the following before installing the Cellular Gateway outdoors:
  •  If the unit is installed outdoors, additional precautions may need to be taken to ensure the 

wire entry at the bottom of the node is adequately sealed (with silicon or something similar) 

to prevent water intrusion . 

  •  Do not install in direct sunlight .
  •  Depending on the geographical location, condensation buildup inside the enclosure is a concern .

Summary of Contents for SentryPlus Alert

Page 1: ...User Guide SentryPlus Alert Cellular Gateway...

Page 2: ...about the different LED lights buttons and connectors inside the SentryPlus Alert Cellular Gateway as well as troubleshooting suggestions if needed For more information about the Cellular Gateway see...

Page 3: ...s off this is a normal state for five seconds Green blink 30 sec 10 min The device is searching for a cellular connection Cyan blink fast A cellular connection has been established and the device is c...

Page 4: ...evice s firmware Replace the device Contact Syncta s Customer Support team at 888 725 4285 Green blink 10 min No cellular connection is available in this location See Poor or No Cellular Reception on...

Page 5: ...ESET Press this to reset the Cellular Gateway and restart the device This will cause all ongoing operations to cease Note You can also perform a full reset by unplugging the Cellular Gateway for 10 se...

Page 6: ...6 UserGuide SentryPlusAlert 2007 2020 Watts Terminals The FLOOD terminals connect the Cellular Gateway to the Junction box The GND 12Vdc terminals connect the Cellular Gateway to a power outlet...

Page 7: ...uctions particularly anything metallic Solution 1 Move the Cellular Gateway to a location where the antenna is not facing any internal walls wires pipes or other obstructions such as an electrical box...

Page 8: ...have carrier coverage at your site Contact Syncta s Customer Support team at 888 725 4285 for more information POWER LED is Off If the POWER LED is off make sure the Cellular Gateway is plugged in and...

Page 9: ...evice Failure to do so may result in electrocution personal injury and or death WARNING Troubleshooting continued 1 Unplug the power cord connected to the Cellular Gateway 2 Using a 2 Phillips head sc...

Page 10: ...the GND and 12Vdc wiring to the terminals 5 Once the screws are loose enough carefully remove the wires by gently pulling them away from the terminals note which wire went into which terminal and rev...

Page 11: ...in place 8 Place the cover back on the Cellular Gateway ensuring that the rubber seal remains in place paying special attention to each corner near the screw holes 9 Using a 2 Phillips head screwdrive...

Page 12: ...lication improper installation or improper maintenance or alteration of the product Some States do not allow limitations on how long an implied warranty lasts and some States do not allow the exclusio...

Reviews: