Troubleshooting (continued)

Possible Cause 3

Cellular reception might not be supported at your site . 
The Cellular Gateway operates using 3G technology on band 2 or 5 . 

Mobile phone 

reception is not a reliable indicator of expected signal strength for the  

Cellular Gateway.

Solution 3

If you cannot find cellular reception anywhere at your site, you may not have carrier coverage 

at your site . Contact Syncta’s Customer Support team at 888-725-4285 for more information .

POWER LED is Off

If the POWER LED is off, make sure the Cellular Gateway is plugged in and that the power 

outlet is active . If the device is still not working, review the possible cause and solution below .

Possible Cause

If the Cellular Gateway is plugged in and the POWER LED is off, the +12Vdc & GND wiring 

inside the Cellular Gateway might have been accidentally swapped .

Solution

Use the instructions on the next several pages to swap the +12Vdc and GND wiring inside the 

Cellular Gateway .

Summary of Contents for SentryPlus Alert

Page 1: ...User Guide SentryPlus Alert Cellular Gateway...

Page 2: ...about the different LED lights buttons and connectors inside the SentryPlus Alert Cellular Gateway as well as troubleshooting suggestions if needed For more information about the Cellular Gateway see...

Page 3: ...s off this is a normal state for five seconds Green blink 30 sec 10 min The device is searching for a cellular connection Cyan blink fast A cellular connection has been established and the device is c...

Page 4: ...evice s firmware Replace the device Contact Syncta s Customer Support team at 888 725 4285 Green blink 10 min No cellular connection is available in this location See Poor or No Cellular Reception on...

Page 5: ...ESET Press this to reset the Cellular Gateway and restart the device This will cause all ongoing operations to cease Note You can also perform a full reset by unplugging the Cellular Gateway for 10 se...

Page 6: ...6 UserGuide SentryPlusAlert 2007 2020 Watts Terminals The FLOOD terminals connect the Cellular Gateway to the Junction box The GND 12Vdc terminals connect the Cellular Gateway to a power outlet...

Page 7: ...uctions particularly anything metallic Solution 1 Move the Cellular Gateway to a location where the antenna is not facing any internal walls wires pipes or other obstructions such as an electrical box...

Page 8: ...have carrier coverage at your site Contact Syncta s Customer Support team at 888 725 4285 for more information POWER LED is Off If the POWER LED is off make sure the Cellular Gateway is plugged in and...

Page 9: ...evice Failure to do so may result in electrocution personal injury and or death WARNING Troubleshooting continued 1 Unplug the power cord connected to the Cellular Gateway 2 Using a 2 Phillips head sc...

Page 10: ...the GND and 12Vdc wiring to the terminals 5 Once the screws are loose enough carefully remove the wires by gently pulling them away from the terminals note which wire went into which terminal and rev...

Page 11: ...in place 8 Place the cover back on the Cellular Gateway ensuring that the rubber seal remains in place paying special attention to each corner near the screw holes 9 Using a 2 Phillips head screwdrive...