background image

Introduction

The Watts SmartStream

 line of ultraviolet disinfection systems 

provide protection against microbiological contamination in water for 

residential and commercial applications. 
Disinfection of water with SmartStream

 is a simple, rapid physical 

process. When contaminated water is exposed to SmartStream's

 

254 nanometer UV light, the UV light penetrates the cell walls of mi-

croorganisms and disrupts their genetic deoxyribonucleic acid (DNA) 

material. This quickly inactivates microorganisms by destroying their 

ability to replicate and infect.

Installation, Operation and 
Maintenance Manual

 

254 Nanometer Germicidal  

UV Disinfection Systems

Models

WA002  WA006  WA008  WA012 

SmartStream

 UV 

Chemical Free Disinfection of Water

IOM-WQ-SmartStream-A

 

Read this Manual BEFORE using this 

equipment. Failure to read and follow 

all safety and user information can 

result in death, serious personal injury, 

property damage, or damage to the equipment. 

Keep this Manual for future reference.

WARNING

!

Installation Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Specification Tables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Feed Water Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Procedure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lamp and Quartz Sleeve Replacement . . . . . . . . . . . . . . . . . . . . . . . 8
Disinfection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Warranty and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Table of Contents

 

This system should only be installed and main-

tained by a qualified professional. The system 

MUST be installed in accordance with all appli-

cable national, state and local codes.

   

NOTICE

DO

 

NOT

 rely solely on this system to make 

water safe to drink. SmartStream

 UV disinfec-

tion systems are intended to be used as part of 

a well designed water treatment system. Water 

that contains microbiological contamination 

should be tested regularly to ensure its quality 

and safety at the point of use.

WARNING

!

DO

 

NOT

 look directly at the UV lamp while it is 

ON. Permanent serious eye injury could occur.

WARNING

!

SmartStream  UV is certified by the Water Quality
Association (WQA) to NSF/ANSI Standard 372 
for lead free.

Summary of Contents for SmartStream UV WA002

Page 1: ...ty damage or damage to the equipment Keep this Manual for future reference WARNING Installation Precautions 2 System Specifications 3 Product Specification Tables 4 Dimensions 4 Feed Water Requirements 5 Installation Procedure 5 Installation Diagram 6 Maintenance 7 Parts List 7 Lamp and Quartz Sleeve Replacement 8 Disinfection Procedure 9 Troubleshooting 9 Warranty and Conditions 10 Table of Conte...

Page 2: ...ream system Be certain that the feed water meets all criteria within the Feed Water Specifications section of this manual WARNING Installation Guidelines DO NOT allow this system to remain ON with out water in it for extended periods of time DO NOT install the system near any source of heat Also DO NOT install the system near any device or break out area that would be adversely effected by water D...

Page 3: ...he system requires servicing SmartStream UV System Part Number Identification Key Prefix W Controller Series GPM Connection Type Pipe Size Plug Accessories Watts Controller Type A Controller A GPM of System 3 Digits Connection Port Types A NPT B BSP Tapered Pipe Size B 3 8 C 1 2 D 3 4 E 1 A North American 120V B European 220V Accessories X No Accessories Green Red LED Indicator System Features A S...

Page 4: ...Red LED AUDIBLE ALARM Yes AUDIBLE ALARM MUTE No MIN MAX AMBIENT AIR TEMPERATURE MAX HUMIDITY 32 F 0 C to 122 F 50 C 90 RH non condensing INLET WATER TEMPERATURE RANGE 36 F 2 C to 104 F 40 C MAX WATER PRESSURE 100 psi 689 kPa SHIPPING WEIGHT 4 6 lbs 2 1 Kg 6 4 lbs 2 9 Kg 8 lbs 3 7 Kg 11 lbs 5 Kg Dimensions A Series UV Systems Model GPM A B C D E F WA002 2 1 1 14 17 17 65 3 83 3 09 14 WA006 6 1 2 22...

Page 5: ...ith a paper towel 15 Loosen the Phillips set screw on the side of the quartz sleeve nut and separate the nut from the power cord 16 Install the quartz sleeve nut o ring onto the visible end of the quartz sleeve Screw the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 17 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it ...

Page 6: ...6 Typical Installation Diagram ...

Page 7: ...VQS6 UV QUARTZ SLEEVE FOR 6 GPM 530MM X 24 5MM A SERIES 2c 1 WUVQS8 UV QUARTZ SLEEVE FOR 8 GPM 680MM X 24 5MM A SERIES 2d 1 WUVQS12 UV QUARTZ SLEEVE FOR 12 GPM 910MM X 24 5MM A SERIES 3 1 HSFSUVOR UV QUARTZ SLEEVE O RING FOR A SERIES 4a 1 WUVLAMP2 UV LAMP FOR 2 GPM A SERIES 4b 1 WUVLAMP6 UV LAMP FOR 6 GPM A SERIES 4c 1 WUVLAMP8 UV LAMP FOR 8 GPM A SERIES 4d 1 WUVLAMP12 UV LAMP FOR 12 GPM A SERIES ...

Page 8: ...artz sleeve into the reactor chamber Be careful not to force the quartz sleeve breakage may occur Then install the o ring over the quartz sleeve 9 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the quartz sleeve nut on clockwise and tighten hand tight 10 Turn on the inlet valve and check for leaks Repair leaks as needed 11 Insert a new lamp into the quartz sleeve...

Page 9: ... connection Low pressure after system Clogged prefilter Replace prefilter Quartz sleeve nut leaks Quartz sleeve nut loose Tighten quartz sleeve nut O ring is defective Replace o ring All problem conditions called out within this troubleshooting chart require the disinfection procedure to be conducted after the corrective action has been completed NOTICE 1 Shut off the isolation valves on the cartr...

Page 10: ...hed installation and operation manual product specifi cation sheet and local plumbing codes This product must be installed in connection with an approved water supply This product must be operated at water pressures and temperatures that do not exceed the Company s published specifications This product is limited to use within atmospheric environments indoors that are within ambient temperature li...