2

 

•  

DO NOT

 let the system freeze. System dam-

age may result.

• Install the system on a flat, and level surface.

•  The quality of the water to be treated must 

meet the feed water guidelines within this 

manual. Failure to ensure proper pretreatment 

will result in inadequate disinfection. Watts 

SmartStream

 UV systems are engineered 

with the highest quality components. If at 

anytime a component needs to be replaced, 

use only parts recommended and supplied 

by Watts.  

DO NOT

 add components to or 

remove components from this system.

The UV lamp is rated for 9000 hours under 

normal operating conditions and should be 

replaced annually to keep the UV intensity at 

the highest possible output. Quartz sleeves 

should be cleaned as needed or replaced as 

needed to guarantee the highest possible UV 

transmittance into the water.
Use only Watts supplied UV lamps and quartz 

sleeves for your specific model. Failure to do so 

may result in system failure, injury, death, prop-

erty damage and will void all warranty. 

DO NOT

 use this system in a manner that it 

is not intended for. This purifier is only for use 

in water applications where the feed water, 

installation environment and installation method 

meets the requirements within this manual.
The system must be properly sized. 

DO NOT

 

exceed the rated flow rate capacity of the sys-

tem. Flow controllers are available from Watts 

to ensure system's rated flow is not exceeded.
Failure to comply with any and all written 

instructions for this product may result in sys-

tem failure, injury, death, property damage and 

will void all warranty.
Follow all product safety labeling.

   

NOTICE

Using SmartStream

 with other water treat-

ment equipment.

SmartStream

 UV units can be installed as a 

final disinfection method within a water treatment 

system train or as pretreatment to protect sensi-

tive components, such as reverse osmosis mem-

branes, from bio-films. 

The injection of chemicals into the water should be 

done on the outlet of the SmartStream

 system to 

ensure UV light degradation of the chemical or the 

introduction of turbidity within the UV feedstream 

does not occur.

A 5 micron particle filter should always be installed 

immediately before the SmartStream

 system. 

Be certain that the feed water meets all criteria 

within the Feed Water Specifications section of 

this manual.

WARNING

!

Installation Guidelines

•  

DO NOT

 allow this system to remain ON with-

out water in it for extended periods of time.

•  

DO

 

NOT

 install the system near any source 

of heat. Also, 

DO

 

NOT

 install the system near 

any device or break out area that would be 

adversely effected by water.

• 

 DO

 

NOT

 install this system higher in elevation 

than 10,000 feet above sea level.

•  

DO

 

NOT

 install the system backwards with the 

feed water line connected to the outlet.

•  

DO

 

NOT

 install where system is exposed to 

harsh chemicals or may be subjected to being 

struck by moving equipment, carts, mops or 

any other item that may cause damage.

•  

DO

 

NOT

 install the system outdoors. Keep 

system away from moisture, rain, and direct 

sunlight. Ambient air temperature must remain 

below 122°F and relative humidity must remain 

below 90%.

•  

DO

 

NOT

 allow the system to freeze.

•   The  system 

MUST

 be mounted on a surface 

and with mounting hardware that is sturdy 

enough to support the weight of the wetted 

system.

•   The  system 

MUST

 be plugged into an uninter-

rupted power supply that matches the rated 

power requirement of the system.

•   The  system 

MUST

 be installed in accordance 

with all applicable national, state and local 

codes.

•  A prefilter with a 5 micron minimum particle size 

reduction must be installed on the inlet line to 

the system. Additional pretreatment may be 

necessary so that the feedwater conforms to 

the Feed Water Specifications section on page 

5.

•  Plumbing materials sensitive to UV light, typi-

cally plastic materials, should not be connected 

directly to the system. To prevent UV degrada-

tion at the plumbing connection points on the 

system, use one foot minimum of copper or 

stainless steel plumbing material to connect to 

the inlet and to the outlet of the system. 

• 

 IF

 water hammer is evident, install water ham-

mer arrestors before the system. 

•  Always back-up valves and fittings with a 

wrench when constructing plumbing to reduce 

unnecessary stress on the system and its 

plumbing.

Position the system in a suitable location. Make 

sure there is enough clearance between the end 

of UV chamber and any obstructions, to allow for 

the removal of the lamp and quartz sleeve.

SmartStream

 UV disinfection systems should be 

installed as close as possible to the treated wa-

ter's point of use.

WARNING

!

Summary of Contents for SmartStream UV WA002

Page 1: ...ty damage or damage to the equipment Keep this Manual for future reference WARNING Installation Precautions 2 System Specifications 3 Product Specification Tables 4 Dimensions 4 Feed Water Requirements 5 Installation Procedure 5 Installation Diagram 6 Maintenance 7 Parts List 7 Lamp and Quartz Sleeve Replacement 8 Disinfection Procedure 9 Troubleshooting 9 Warranty and Conditions 10 Table of Conte...

Page 2: ...ream system Be certain that the feed water meets all criteria within the Feed Water Specifications section of this manual WARNING Installation Guidelines DO NOT allow this system to remain ON with out water in it for extended periods of time DO NOT install the system near any source of heat Also DO NOT install the system near any device or break out area that would be adversely effected by water D...

Page 3: ...he system requires servicing SmartStream UV System Part Number Identification Key Prefix W Controller Series GPM Connection Type Pipe Size Plug Accessories Watts Controller Type A Controller A GPM of System 3 Digits Connection Port Types A NPT B BSP Tapered Pipe Size B 3 8 C 1 2 D 3 4 E 1 A North American 120V B European 220V Accessories X No Accessories Green Red LED Indicator System Features A S...

Page 4: ...Red LED AUDIBLE ALARM Yes AUDIBLE ALARM MUTE No MIN MAX AMBIENT AIR TEMPERATURE MAX HUMIDITY 32 F 0 C to 122 F 50 C 90 RH non condensing INLET WATER TEMPERATURE RANGE 36 F 2 C to 104 F 40 C MAX WATER PRESSURE 100 psi 689 kPa SHIPPING WEIGHT 4 6 lbs 2 1 Kg 6 4 lbs 2 9 Kg 8 lbs 3 7 Kg 11 lbs 5 Kg Dimensions A Series UV Systems Model GPM A B C D E F WA002 2 1 1 14 17 17 65 3 83 3 09 14 WA006 6 1 2 22...

Page 5: ...ith a paper towel 15 Loosen the Phillips set screw on the side of the quartz sleeve nut and separate the nut from the power cord 16 Install the quartz sleeve nut o ring onto the visible end of the quartz sleeve Screw the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 17 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it ...

Page 6: ...6 Typical Installation Diagram ...

Page 7: ...VQS6 UV QUARTZ SLEEVE FOR 6 GPM 530MM X 24 5MM A SERIES 2c 1 WUVQS8 UV QUARTZ SLEEVE FOR 8 GPM 680MM X 24 5MM A SERIES 2d 1 WUVQS12 UV QUARTZ SLEEVE FOR 12 GPM 910MM X 24 5MM A SERIES 3 1 HSFSUVOR UV QUARTZ SLEEVE O RING FOR A SERIES 4a 1 WUVLAMP2 UV LAMP FOR 2 GPM A SERIES 4b 1 WUVLAMP6 UV LAMP FOR 6 GPM A SERIES 4c 1 WUVLAMP8 UV LAMP FOR 8 GPM A SERIES 4d 1 WUVLAMP12 UV LAMP FOR 12 GPM A SERIES ...

Page 8: ...artz sleeve into the reactor chamber Be careful not to force the quartz sleeve breakage may occur Then install the o ring over the quartz sleeve 9 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the quartz sleeve nut on clockwise and tighten hand tight 10 Turn on the inlet valve and check for leaks Repair leaks as needed 11 Insert a new lamp into the quartz sleeve...

Page 9: ... connection Low pressure after system Clogged prefilter Replace prefilter Quartz sleeve nut leaks Quartz sleeve nut loose Tighten quartz sleeve nut O ring is defective Replace o ring All problem conditions called out within this troubleshooting chart require the disinfection procedure to be conducted after the corrective action has been completed NOTICE 1 Shut off the isolation valves on the cartr...

Page 10: ...hed installation and operation manual product specifi cation sheet and local plumbing codes This product must be installed in connection with an approved water supply This product must be operated at water pressures and temperatures that do not exceed the Company s published specifications This product is limited to use within atmospheric environments indoors that are within ambient temperature li...

Reviews: